• Title/Summary/Keyword: 3차원유한차분해석

Search Result 172, Processing Time 0.03 seconds

The Effect of Cement Milk Grouting on the Deformation Behavior of Jointed Rock Mass (시멘트현탁액 주입에 의한 절리암반의 역학적 특성 변화)

  • 김태혁;이정인
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.331-343
    • /
    • 2003
  • Though the Grouting has been in use for a long time, it is still regarded as an technique rather than engineering. The study of ground improvement by grouting is rare especially in jointed rock mass. In this study, biaxial compression tests were performed in the jointed rock mass models with .ough surfBce joints assembled with blocks before and after grouting. The load-deformation curves of the jointed rock masses showed a non-linear relationship before grouting but showed a relatively linear deformaion behavior after grouting. Improvement ratio (deformation modulus after grouting/deformation modulus before grouting) decreased with increasing joint spacing and lateral stress. Improvement ratio decreased exponentially with increasing deformation modulus of the rock mass model before grouting. Three-dimensional FDM analysis was performed to a highway tunnel case using experimental data of grouted rock. The convergence of the tunnel predicted after grouting by the numerical modelling coincided with those attained from the field measurement.

The 3-Dimensional Tunnel Analysis Considering Stress Concentration . Load Distribution Ratio (응력집중을 고려한 터널의 3차원 거동에 관한 연구 -하중분담률 중심으로)

  • 이인모;최항석
    • Geotechnical Engineering
    • /
    • v.12 no.1
    • /
    • pp.87-110
    • /
    • 1996
  • To simulate the three4imensional effect occurring near the tunnel face in a two -dimensional model, empirical load -dirtribution ratio concept is frequently used in tunnel design. In this paper, three -dimensional analysis is performed and its results are compared with those of two dimensional analysis'to investigate the applicability of the loadiistribution ratio concept. Especially, stress concentration near the tunnel face is investigated in depth. A parametric study is performed to investigate the effect of each factor on the load distribution ratio. The factors considered here include unsupported span length, initial stress, rock quality, tunnel size and the depth of tunnel location Moreover, the load -distribution ratios for the typical tunnel sections in Seoul Subway to be used in the tunnel design are suggested.

  • PDF

A Three-Dimensional Numerical Model of Hydrodynamic Flow on σ-Coordinate (연직변환좌표(鉛直變換座標)에서 3차원(次元) 유동(流動) 수직모형(數値模型))

  • Jung, Tae Sung;Lee, Kil Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1145-1158
    • /
    • 1994
  • A three-dimensional, finite difference, numerical model with free surface was developed on ${\sigma}$-coordinate. A semi-implicit numerical scheme in time has been adopted for computational efficiency. The scheme is essentially independent of the stringent stability criteria (CFL condition) for explicit schemes of external surface gravity wave. Implicit algorithm was applied for vertical shear stress, Coriolis force and pressure gradient terms. The reliability of the model with vertically variable grid system was checked by the comparison of simulation results with analytic solution of wind-driven currents in a one-dimensional channel. Sensitivity analysis of differencing parameters was carried out by applying the model to the calculation of wind-driven currents in a square lake.

  • PDF

Analysis of circular waveguide transformer using FDTD (원형 도파관 정합기의 FDTD에 의한 해석)

  • 이동국;홍재표
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 2003
  • The finite-difference time-domain (FDTD) method is used to analyze circular waveguide transformer in order to match different two waveguides. 2-dimensional cylindrical FDTD algorithm is applied for rotationally symmetric. The transformer is inserted at a circular-to-circular waveguide junction and two type transformers are proposed. One is a partially dielectric filled circular waveguide type and the other is filled a tapered circular dielectric rod. The numerical results are derived for various structure parameters, such as transformer length. dielectric diameter and waveguide diameter.

  • PDF

Sub- Breaking Analysis of Free Surface Flows by the Numerical Simulation (수치 시뮬레이션을 통한 자유표면 유동의 Sub-Breaking 해석)

  • Kwag, Seung-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.28 no.8
    • /
    • pp.753-757
    • /
    • 2004
  • The free-surface flow is simulated to make clear the viscous interaction of stem waves and the sub-breaking phenomena around a high speed vehicle. The Navier-Stokes equation is solved by a finite difference method where the body-fitted coordinate system, the wall function and the triple-grid system are invoked They are applied to study precisely on the stem flow of S-103 as to which extensive experimental data are available. Computations are extended to the submerged revolutional body. The numerical result shows that the gradient of M/Us is greatly influenced by the submerged depth And the stem wave is influenced by the separation due to the bow wave.

The deformation behavior of soil tunnels reinforced with RPUM and fiberglass pipes (RPUM과 유리섬유 파이프로 막장을 보강한 토사터널의 변형거동)

  • Nam, Gi-Chun;Heo, Young;Kim, Chi-Whan;You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.185-193
    • /
    • 2002
  • In this paper, deformation behavior of shallow subway tunnel excavated in weathered soil and reinforcement effects of longitudinal support measures are investigated via three dimensional FDM analysis. Two excavation methods, half-face excavation and full-face excavation, are considered in simulation to study the influences of excavation methods on tunnel deformation behavior. In addition, the reinforcing effects of RPUM and fiberglass pipe are compared. Face extrusion, covergence, preconvergence, and sidewall displacement are investigated to analyze tunnel deformation behavior, and surface settlement is used to analyze the effects of excavation methods and longitudinal supports measures. The simulation results show that half-face excavation induces larger convergence, preconvergence, sidewall displacement, surface settlement than full-face excavation, while full-face excavation induces larger extrusion than half-face excavation. In addition, under same excavation method, all displacements are larger when RPUM is only used for longitudinal support than when RPUM is jointly used with fiberglass pipes.

  • PDF

Incompressible Laminar Entry Flows in a Square Duct of Strong Curvature Using an Implicit SMAC Scheme (SMAC 음해법에 의한 큰 곡률를 갖는 정사각형 덕트내의 비압축성 층류 입구유동)

  • Shin B. R.;Ikohagi T.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.35-46
    • /
    • 1996
  • 원심형 임펠러 내부 유로등 큰 곡률을 수반하는 터보기계 요소의 유동해석을 위한 계산코드를 개발하였다. 이 코드에서는 곡선좌표계에 유도된 3차원 비압축성 Navier-Stokes의 운동 방정식을 SMAC 음해법으로 푼다. 이 코드를 이용하여 유로의 단면이 정사각형이고 90도로 굽은 덕트내부의 층류 입구유동을 해석하고, 굽은 관 특유의 유동현상을 수치모사하였다 또한 곡관부 입구에서 충분히 발달한 유동, 또는 발달중인 유동이 유입될 경우에 이것이 곡관부 내부의 유동에 미치는 영향을 상·하류의 계산영역이 서로 다를 몇몇 유동장에 대하여 조사하고, 본 계산에서 얻어진 결과와 실형결과와의 비교로 본 3차원 유동해석 코드의 유효성을 검토 하였다.

  • PDF

3-D Dynamic Response of Buried Pipelines (매설관의 3차원 동적응답거동)

  • Jeong, Jin-Ho;Kim, Chun-Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.27-35
    • /
    • 2011
  • Larbi (1995) and Jeong et al. (2005) analyzed the various boundary end conditions of buried pipelines using the mode superposition method as one of the dynamic analysis methods of buried pipelines. However, it is very complicated to derive calculation equations for the solutions to be obtained by this method, and even the derived calculation equations need separate computer programming for the numerical analysis in order to obtain the solutions. For this reason, this method is extremely difficult for engineers to apply in their field works. In consideration of the shortcoming of the mode superposition method, this study's purpose is to propose a 3D dynamic finite difference method, which is more easily applicable in the field. For this purpose, we tested the accuracy of the 3D dynamic analysis and compared the results with those of the mode superposition method and certified that the 3D dynamic analysis could be an alternative method to obtain the seismic responses of the pipelines.

Numerical Modeling for Air-Side Flow Characteristics of Fin-TUbe Heat Exchangers for Air-Conditioning Applications (공조용 핀-관 열교환기의 공기측 열유동특성에 대한 수치모사)

  • 김승택;최윤호
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.309-318
    • /
    • 2000
  • 핀-관 열교환기의 효율을 증대시키기 위하여는 열저항을 결정하는 데 있어서 중요한 역할을 하는 공기측 열전달 특성의 향상이 필요하다. 본 연구에서는 핀-관 열교환기의 공리측 성능을 해석하기 위해서 3차원 비압축성 Navier-Stokes 코드를 개발하였으며 이 코드는 시간항에 스칼라 내재적 근사분해법(scalar implicit approximate factorization)절차, 공간항에 유한체적법과 2차의 풍상차분법(upwind differencing)을 사용한다. 서로 다른 3개의 핀형상(평판핀, 슬릿핀, 파형핀)을 고려하였고 이들의 유동 및 열전달 특성을 연구하였다.

  • PDF

A Study on the Side Shear Developed during Pullout of Suction Pile in Clays using 3D Numerical Analysis (3차원 수치해석을 이용한 점토지반에 설치된 석션파일 인발 시 발현되는 전단응력에 관한 연구)

  • Lee, Myungjae;Youn, Heejung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.59-66
    • /
    • 2014
  • This paper presents the pullout behavior of suction pile using finite difference method; and the commercial software, FLAC3D, was employed for the numerical analyses. The ultimate pullout capacity of suction pile was predicted using conventional equations, and the results were compared with the results from numerical analyses with varying pile diameter, pile length, and the undrained shear strength of clays. Based on the results from 24 analyses, it was found that the failure pattern depends not only on the drainage condition of suction pile, but also on the pile dimensions and the material properties of surrounding soils. The developed side shear (DSS) along the internal surface of the suction pile was collected from numerical analyses, which was used to classify the failure type between sliding failure and tensile failure. Regardless of the external DSS, the high internal DSS tends to result in sliding failure in the numerical analyses, which conforms well to the estimation from conventional equations.