• 제목/요약/키워드: 3^{pulsed}$

검색결과 1,290건 처리시간 0.027초

펄스레이저법으로 증착 제조된 AlN박막의 타겟 효과 (Effect of Targets on Synthesis of Aluminum Nitride Thin Films Deposited by Pulsed Laser Deposition)

  • 정준기;하태권
    • 소성∙가공
    • /
    • 제29권1호
    • /
    • pp.44-48
    • /
    • 2020
  • Aluminum nitride (AlN), as a substrate material in electronic packaging, has attracted considerable attention over the last few decades because of its excellent properties, which include high thermal conductivity, a coefficient of thermal expansion that matches well with that of silicon, and a moderately low dielectric constant. AlN films with c-axis orientation and thermal conductivity characteristics were deposited by using Pulsed Laser Deposition (PLD). The epitaxial AlN films were grown on sapphire (c-Al2O3) single crystals by PLD with AlN target and Y2O3 doped AlN target. A comparison of different targets associated with AlN films deposited by PLD was presented with particular emphasis on thermal conductivity properties. The quality of AlN films was found to strongly depend on the growth temperature that was exerted during deposition. AlN thin films deposited using Y2O3-AlN targets doped with sintering additives showed relatively higher thermal conductivity than while using pure AlN targets. AlN thin films deposited at 600℃ were confirmed to have highly c-axis orientation and thermal conductivity of 39.413 W/mK.

PLD를 이용한 (100) $LaAlO_3$ 기판위의 ZnO 에피택셜 박막 성장 (Epitaxial Growth of ZnO Thin Films on (100) $LaAlO_3$ Substrate by Pulsed Laser Deposition)

  • 조대형;김지홍;문병무;조영득;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.256-256
    • /
    • 2008
  • We report epitaxial growth of ZnO thin films on (100) single-crystalline $LaAlO_3$ (LAO) substrates using pulsed laser deposition (PLD) at different substrate temperatures (400~$800^{\circ}C$). The structural and electrical properties of the films have been investigated by means of X-ray diffraction (XRD), atomic force microscope (AFM), transmission line method (TLM). The poly-crystalline of $\alpha$- and c-axis oriented ZnO film was formed at lower deposition temperature ($T_s$) of $400^{\circ}C$. At higher $T_s$, however, the films exhibit single-crystalline of $\alpha$-axis orientation represented by ZnO[$\bar{1}11$ || LAO <001>. The electrical properties of ZnO thin films depend upon their crystalline orientation, showing lower electrical resistivity values for $\alpha$-axis oriented ZnO films.

  • PDF

WISE 펄스 도플러 윈드라이다 품질관리 알고리즘 개발 (Development of a Quality Check Algorithm for the WISE Pulsed Doppler Wind Lidar)

  • 박문수;최민혁
    • 대기
    • /
    • 제26권3호
    • /
    • pp.461-471
    • /
    • 2016
  • A quality check algorithm for the Weather Information Service Engine pulsed Doppler wind lidar is developed from a view point of spatial and temporal consistencies of observed wind speed. Threshold values for quality check are determined by statistical analysis on the standard deviation of 3-component of wind speed obtained by a wind lidar, and the vertical gradient of horizontal wind speed obtained by a radiosonde system. The algorithm includes carrier-to-noise ratio (CNR) check, data availability check, and vertical gradient of horizontal wind speed check. That is, data sets whose CNR is less than -29 dB, data availability is less than 90%, or vertical gradient of horizontal wind speed is less than $-0.028s^{-1}$ or larger than $0.032s^{-1}$ are classified as 'doubtful', and flagged. The developed quality check algorithm is applied to data obtained at Bucheon station for the period from 1 to 30 September 2015. It is found that the number of 'doubtful' data shows maxima around 2000 m high, but the ratio of 'doubtful' to height-total data increases with increasing height due to atmospheric boundary height, cloud, or rainfall, etc. It is also found that the quality check by data availability is more effective than those by carrier to noise ratio or vertical gradient of horizontal wind speed to remove an erroneous noise data.

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

Electrical and Optical Properties of Ga-doped SnO2 Thin Films Via Pulsed Laser Deposition

  • Sung, Chang-Hoon;Kim, Geun-Woo;Seo, Yong-Jun;Heo, Si-Nae;Huh, Seok-Hwan;Chang, Ji-Ho;Koo, Bon-Heun
    • 한국표면공학회지
    • /
    • 제44권4호
    • /
    • pp.144-148
    • /
    • 2011
  • $Ga_2O_3$ doped $SnO_2$ thin films were grown by using pulsed laser deposition (PLD) technique on glass substrate. The optical and electrical properties of these films were investigated for different doping concentrations, oxygen partial pressures, substrate temperatures, and film thickness. The films were deposited at different substrate temperatures (room temperature to $600^{\circ}C$). The best opto-electrical properties is shown by the film deposited at substrate temperature of $300^{\circ}C$ with oxygen partial pressure of 80 m Torr and the gallium concentration of 2 wt%. The as obtained lowest resistivity is $9.57{\times}10^{-3}\;{\Omega}cm$ with the average transmission of 80% in the visible region and an optical band gap (indirect allowed) of 4.26 eV.

Magnetocapacitance Properties of Multilayered CoFe2O4/BaTiO3/CoFe2O4 Thin Film by Pulsed Laser Deposition

  • Lee, Seong Noh;Shim, Hyun Ju;Shim, In-Bo
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.121-125
    • /
    • 2014
  • $CoFe_2O_4(CFO)/BaTiO_3(BTO)/CoFe_2O_4(CFO)$ multilayered thin films were deposited on $Pt/TiO_2/SiO_2/Si$ substrates by the pulsed laser deposition (PLD) system with KrF excimer laser (${\lambda}=248nm$). BTO, CFO, BTO/CFO and CFO/BTO/CFO structured thin films were prepared and their crystal structures and microstructures, as well as their magnetic and magneto-electrical properties, were studied. The C-V characteristics of these multilayered thin films with different capacitor structures were obtained to confirm the change in their capacitances under a magnetic field. Finally, the capacitance of the CFO/BTO/CFO thin film as a function of bias voltage under an in-plane magnetic field of 1,000 Oe increased to 951.04 pF at 1 MHz, from 831.90 pF measured under no magnetic field, indicating 14.3% increase in magnetocapacitance.

Thermal Effect on Characteristics of IZTO Thin Films Deposited by Pulsed DC Magnetron Sputtering

  • Son, Dong-Jin;Ko, Yoon-Duk;Jung, Dong-Geun;Boo, Jin-Hyo;Choa, Sung-Hoon;Kim, Young-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.847-851
    • /
    • 2011
  • This study examined In-Zn-Sn-O (IZTO) films deposited on glass substrates by pulsed DC magnetron sputtering with various substrate temperatures. The structural, electrical, optical properties were analyzed. Xray diffraction showed that the IZTO films prepared at temperatures > $150^{\circ}C$ were crystalline which adversely affected the electrical properties. Amorphous IZTO films prepared at $100^{\circ}C$ showed the best properties, such as a low resistivity, high transmittance, figure of merit, and high work function of $4.07{\times}10^{-4}\;{\Omega}$, 85%, $10.57{\times}10^{-3}\;{\Omega}^{-1}$, and 5.37 eV, respectively. This suggests that amorphous IZTO films deposited at relatively low substrate temperatures ($100^{\circ}C$) are suitable for electrode applications, such as OLEDs as a substitute for conventional crystallized ITO films.

Growth of oriented $LaF_{3}$ thin films on Si (100) substrates by the pulsed laser deposition method

  • Yokotani, Atsushi;Ito, Tomomi;Sato, Akiko;Kurosawa, Kou
    • 한국결정성장학회지
    • /
    • 제13권4호
    • /
    • pp.157-164
    • /
    • 2003
  • $LaF_{3}$ thin films have been fabricated on Si (100) substrates under the highest possible vacuum condition by pulsed laser deposition (PLD) method. The temperature of the sbustrate varied from $20^{\circ}C$ to $800^{\circ}C$. The films deposited at the higher temperature indicated the sharper peaks in the X-ray diffraction measurement. A highly oriented film was successfully obtained at a substrate temperature of $800^{\circ}C$. The surface observation by the AFM revealed that the many hexagonal structures constructed the film. The XPS analysis revealed that the lacking of F in the film deposited at $600^{\circ}C$ were much more than that in film at $^20{\circ}C$. Adding the adequate amount of $CF_{4}$ gas in the growth chamber can compensate this lacking of F.

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

RP-HPLC-PAD를 이용한 갈근(葛根)과 갈근(葛根) 함유 처방의 Puerarin과 Daidzin 분석 (Determination Method of Puerarin and Daidzin from Puerariae Radix by Reversed-Phase HPLC with Pulsed Amperometric Detection)

  • 초진영;권하정;정지선;이제현;홍선표
    • 대한본초학회지
    • /
    • 제23권4호
    • /
    • pp.171-177
    • /
    • 2008
  • Objectives: This study presents a reversed-phase high-performance liquid chromatography- pulsed amperometric detection(RP-HPLC-PAD) method for the determination of puerarin and daidzin in Puerariae Radix extract and Chinese medicinal preparations. Methods: Chromatographic separation was performed using a 10% acetonitrile with a reversed-phase column(Unison UK-C18, $100mm{\times}2.0mm$ I.D.; $3{\mu}m$). The analyses were detected by pulsed amperometric detector(PAD) in alkaline conditions by combining with post-column NaOH solution. Geniposide was used as an internal standard. Results: The limit of detection(S/N=3) and the limit of quantification(S/N=10) were 0.025 ng, 0.075 ng for puerarin, and 0.05 ng, 0.15 ng for daidzin, respectively. The intra- and inter-day precisions(RSDs) were less than 6.5% and average recoveries of puerarin were 99.7-101.3% and those of daidzin were 101.0-102.8%. Conclusions: According to above results, we developed a determination method for puerarin and daidzin in Puerariae Radix with high sensitivity and selectivitely.

  • PDF