• Title/Summary/Keyword: 2DEG

Search Result 1,103, Processing Time 0.027 seconds

콜드헤딩머신의 구동장치에 대한 설계해석

  • 김광영;류병순;윤두표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.794-798
    • /
    • 1995
  • We performed analysis for crank shaft and connecting rod in driving device of Cold Heading Machine. The results of this study is following ; 1. The nominal pressure is happened at 8mm under bottom dead center. And then the theoretical angel of crank (.theta.) and connecting rod (.phi.) are .theta. = 25 .deg. 1' and .phi.= 6 .deg. 1' but the analysis angel are .theta. = 25 .deg. and .phi.= 7 .deg. 2. The load is loaded at theta. = 51 .deg. in crank angle. 3. The maximum stress of connecting rod is about290MPa. It is exited inner stress range in consideration of safety factor.

  • PDF

The effect of inclined ribbed tubes on heat transfer and friction loss (Ribbed 管의 管傾斜角이 熱傳達에 미치는 影響)

  • 박성찬;김종보
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.105-109
    • /
    • 1987
  • Artificial roughness as a means of improving heat transfer gains more interest, especially for application to various heat exchanger. This study present experimental information for single-phase free and force convection heat transfer in a circular tube containing a internal spiral ribs. To examine the effect of inclined angle of tube, it was varied from 0 deg to 90 deg (0.deg., 22.5.deg., 45.deg., 90.deg.) with horizontal. Length of tube is 1.6m, and width, height and helix angle of rib are 4.2mm, 1.5mm, and 60 deg respectively. Water was used as a working fluid and test piece was heated with a constant heat flux by electric heater. Experiments have been performed with the range of modified Grashof number from 2 * 10$^{6}$ to 15 * 10$^{6}$ for free convection and with the range of Reynolds number from 3,000 to 40,000 for forced convection. Since the increase in heat transfer coefficients influence directly to the friction coefficient of the tube, the changes of the friction factors are also presented for several different cases considered in this investigation.

Measurement of turbulent flow characteristics of a rectangular duct with a 180.deg. bend by hot wire anemometer (열선유속계에 의한 180.deg.곡관을 갖는 직사각 단면덕트에서의 난류유동 특성의 측정)

  • 박호영;유석재;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.734-746
    • /
    • 1990
  • Velocities and Reynolds stresses in 3-dimensional turbulent flow in rectangular ducts with a 180.deg. bend were measured by hot wire anemometer. Slant wire was rotated to 4 directions and I type wire was rotated to 2 directions and the voltage outputs of them were combined to obtain the mean velocities and Reynolds stresses. Flow characteristics in the 1.5:1 and 2:1 cross secioned 180.deg. bend were measured and the results were compared with the data from Moon for the square sectioned 180.deg. bend flow. Flows in rectangular sectioned 180.deg. bend show the reduction in secondary flow and therefore the reduction of double maximum in local mean velocities.

ON DELAY DIFFERENTIAL EQUATIONS WITH MEROMORPHIC SOLUTIONS OF HYPER-ORDER LESS THAN ONE

  • Risto Korhonen;Yan Liu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.61 no.1
    • /
    • pp.229-246
    • /
    • 2024
  • We consider the delay differential equations $$b(z)w(z+1)+c(z)w(z-1)+a(z)\frac{w'(z)}{w^k(z)}=\frac{P(z, w(z))}{Q(z, w(z))}$$, where k ∈ {1, 2}, a(z), b(z) ≢ 0, c(z) ≢ 0 are rational functions, and P(z, w(z)) and Q(z, w(z)) are polynomials in w(z) with rational coefficients satisfying certain natural conditions regarding their roots. It is shown that if this equation has a non-rational meromorphic solution w with hyper-order ρ2(w) < 1, then either degw(P) = degw(Q) + 1 ≤ 3 or max{degw(P), degw(Q)} ≤ 1. In addition, it is shown that in the case max{degw(P), degw(Q)} = 0 the equations above can have such a solution, with an additional zero density requirement, only if the coefficients of the equation satisfy certain strict conditions.

Annealing Effect of Surface Magnetic Properties in CoTi Thin Films (열처리 효과가 CoTi계 박막의 표면자기특성에 미치는 영향)

  • 김약연;백종성;이성재;임우영;이수형
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 1997
  • For amorphous $Co_{1-x}Ti_x$(X=0.13, 0.16, 0.21 at.%) thin films deposited by DC magnetron sputtering method ferromagnetic resonance experiments have been used to investigate the dependence of surface magnetic properties according to annealing temperature (150~225 $^{\circ}C$). Spin wave resonance spectra for all annealing temperatures consist of several volume modes and one(or two) surface mode. It is suggested that both surfaces of the film have a perpendicular hard axis to the film plane(negative surface anisotropy). Also, the surface anisotropy $K_{s2}$ at substrate film interface is varied slowly from -0.11 to -0.25 erg/ $\textrm{cm}^2$ and the surface anisotropy $K_{s1}$ at film-air interface is varied from 0.16 to -0.53 erg/ $\textrm{cm}^2$ with increasing annealing temperature. We conjecture that the variation of surface anisotropy $K_{s1}$ is due to the increase of Co concentration resulted from Ti oxidation for low temperature annealing(150~200 $^{\circ}C$) and the diffusion of Co atoms near the film surfaces for high temperature annealing(225~250 $^{\circ}C$).

  • PDF

The Isoinertial Assessment of Lumbar Function in Patients with Chronic Low Back Pain (등저항성삼축동력계(Isostation B-200)를 이용한 만성 요통 환자들의 요추부 기능)

  • Bae, Sung-Il
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.1
    • /
    • pp.14-19
    • /
    • 2004
  • Objective : This study obtained normative values for variable parameters of lumbar function with the isoinertial triaxial dynamometer in patients with chronic low back pain. Subjects and Methods : 30 patients(male 15, female 15) with chronic low back pain in this study. Variable parameters that were measured with the Isostation B-200 were lumbar range of motion, isometric maximum torques, and maximum velocities in three axis. Results : In patient male group mean R.O.M. was $82.9{\pm}12.5$ degrees in lumbar rotation, $76.5{\pm}17.1$ degrees in lumbar flexion/extension, and $64.3{\pm}14.5$ degrees in lumbar lateral flexion. In patient female group mean R.O.M. was $78.4{\pm}18.5$ degrees in lumbar rotation, $71.7{\pm}20.4$ degrees in lumbar flexion/extension, and $63.2{\pm}14.4$ degrees in lumbar lateral flexion. In patient male group mean isometric maximum torques was $64.7{\pm}23.8ft-lbs$ in lumbar rotation, $81.1{\pm}42.0ft-lbs$ in lumbar flexion, $122.2{\pm}43.6ft-lbs$ in lumbar extension, and $101.0{\pm}37.0ft-lbs$ in lumbar lateral flexion. In patient female group mean isometric maximum torques was $41.9{\pm}9.2ft-lbs$ in lumbar rotation, $49.9{\pm}23.9ft-lbs$ in lumbar flexion, $90.1{\pm}26.8ft-lbs$ in lumbar extension, and $62.0{\pm}16.7ft-lbs$ in lumbar lateral flexion. In patient male group mean maximum velocity of isoinertial exercise with low (25%) resistance was $102.4{\pm}28.8deg/sec$ in lumbar rotation, $108.9{\pm}32.2deg/sec$ in lumbar flexion/extension, and $103.5{\pm}30.4deg/sec$ in lumbar lateral flexion. In patient female group mean maximum velocity of isoinertial exercise with low (25%) resistance was $84.1{\pm}24.4deg/sec$ in lumbar rotation, $93.2{\pm}32.9deg/sec$ in lumbar flexion/extension, and $98.5{\pm}33.7deg/sec$ in lumbar lateral flexion. In patient male group mean maximum velocity of isoinertial exercise with high (50%) resistance was $74.0{\pm}20.9deg/sec$ in lumbar rotation, $98.7{\pm}32.8deg/sec$ in lumbar flexion/extension, and $85.0{\pm}25.8deg/sec$ in lumbar lateral flexion. In patient female group mean maximum velocity of isoinertial exercise with high (50%) resistance was $67.3{\pm}26.4deg/sec$ in lumbar rotation, $82.5{\pm}31.0deg/sec$ in lumbar flexion/extension, and $79.7{\pm}23.9deg/sec$ in lumbar lateral flexion. Conclusion : Maximum isoinertial velocities were more reliable and more significant than isometric maximum torque for the objective assessment of chronic low hack pain.

  • PDF

Studies on the Stability of Hexamine Aqueous Solution (Hexamine 수용액의 안정성에 관한 연구)

  • 우종학
    • YAKHAK HOEJI
    • /
    • v.7 no.2_3
    • /
    • pp.51-54
    • /
    • 1963
  • In this experiment, it is found that the decomposition reaction of hexamine aqueous solution by heat is the pseudo first order reaction and the calculated decomposition velocity constants of Hexamine aqueous solution are 1.17 * $10^{-5}min.^{-1}(60{\deg}$ C), 1.99 * $10^{-5}min.^{-1}(70{\deg}$ C), 2.35 * $10^{-5}min.^{-1}(80{\deg}$ C), 6.63 * $10^{-5}min.^{-1}(100{\deg}$ C). In the result, the activation energy of decomposition reaction of hexamine aqueous solution is 12 $Cal.mole^{-1}$.

  • PDF

Sinterability of MgO added mullite based ceramic substrates (MgO첨가 Mullite질회로기판의 소결성)

  • 임병오
    • Electrical & Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.470-475
    • /
    • 1993
  • 1150, 1450, 1600.deg.C에서 MgO-SiO$_{2}$-Al$_{2}$O$_{3}$계를 유리성분으로 하는 mullite-glass질 회로기판재료의 소결거동에 미치는 MgO첨가량과 소성시간에 따른 영향을 조사하였으며 주로 소성시간이 밀도, 기공분포, 미세구조 및 생성상에 미치는 영향을 조사하였다. 1150.deg.C에서는 MgO의 첨가량에 관계없이 소결이 진행되지 않았으며 1450.deg.C에서는 MgO첨가량에 따라 소결속도가 증가하였다. 1600.deg.C에서는 각조성의 시료 모두가 빨리 과소성단계에 도달하였다. 1450.deg.C에서는 MgO 0.85% 첨가했을때 소성시간에 따라 기공량은 감소하는 반면 기공경은 일정하게 증가하였다. 먼저 .alpha.-SiO$_{2}$가 cristobalite로 전이한 후에 MgO와 반응하여 유리상으로 된다.

  • PDF

Numerical Analysis of Natural Convection from a Horizontal Surface Immersed in Cold Water (저온의 물속에 잠겨있는 수평 평면에 의하여 야기되는 자연대류의 수치해석)

  • 유갑종;예용택;권혁용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1195-1204
    • /
    • 1992
  • The natural convection from upward and downward facing horizontal isothermal plate immersed in water is studied numerically. The temperature of the plate is from 0.0 .deg. C to 8.0 .deg. C and the ambient water temperature is from 1.0 .deg. C to 10.0 .deg. C. Numerical results are presented for the velocity profiles, temperature profiles, local heat transfer coefficients, and average Nusselt numbers over the entire flow fields. Flow patterns are shown in the upward and downward facing surfaces at different ambient water temperatures. For the upward facing surface, there are upflow and unsteady flow. And the regions of the ambient water temperatures which give rise to the upflow are more extensive as the temperatures of the isothermal surface become more distant from the density extremum temperature. For the downward facing surface, only the downflow region is shown. For the upward facing horizontal isothermal surface, the average Nusselt number(= N $u_{1}$$^{*}$) is 28.86(Ra)$^{0.01}$. And for the downward facing surface, the average Nusselt number(= N $u_{2}$$^{*}$) is $C_{2}$(Ra)$^{0.2}$ and the values of $C_{2}$ are enlarged in the range of 0.785 .leq. $C_{2}$ .leq. 1.250 as increasing of the temperatures of the isothermal surface.ace.ace.

A Study on the Crack Growth Behavior and Fracture Criterion of Glass/Epoxy Composites (Glass/Epoxy 복합재료의 파괴조건 및 균열진전거동)

  • 김정규;김도식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1681-1690
    • /
    • 1992
  • The effects of the stress ratio and the fiber orientation(0.deg./90.deg. and .+-.45.deg.) to the load direction on the fracture behavior of the glass/epoxy plain woven composites were studied. The tests were carried out using compact tension specimens under both static and fatigue loading. The values of $k_{a}$ obtained from the energy release rate are independent of notch depth(a/w=0.2~0.6) for the 0.deg./90.deg. specimens, but decreases with an increase in a/w for the .+-.45.deg. specimens. And $k_{q}$ has higher values than $k_{ASTM}$ has been evaluated by the ASTM E399 test procedure. It is shown in the relation between fatigue crack growth rate da/dN and stress intensity factor range .DELTA.K using modified shape correction factor that da/dN decreases with a decrease in stress ratio and is lower for .+-..deg. specimens than for 0.deg./90.deg. These phenomena can be explained by the crack deflection to the load direction.n.n.