• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.024초

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가 (Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT))

  • 김진수;이재성;이병일;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.318-324
    • /
    • 2004
  • 목적: Philips GEMINI PET/CT 스캐너는 GSO 섬광결정을 사용해 제작된 전신용 PET/CT 스캐너이다. 이 연구에서는 NEMA에서 새롭게 제안한 NEMA NU2-2001에 따라 GEMINI PET/CT 스캐너의 공간분해능, 민감도, 산란분획, NECR 등을 평가하고 그 결과를 BGO, LSO등의 섬광결정의 특성과 비교하였다. 대상 및 방법: GEMINI는 Philips ALLEGRO PET과 MX8000 D multi-slice CT 스캐너를 결합한 PET/CT 스캐너로서 검출기는 GSO 섬광결정 ($4{\times}6{\times}20mm^3$)을 사용하였고 축방향 시야는 18 cm이다. 공간분해능. 민감도, 산란분획, NECR 등을 평가하기 위하여 PET 데이터를 획득하였다(동시계수창: 8 ns, 에너지창: $409{\sim}664$ keV). 공간분해능 측정을 위하여 축횡단면의 중심에서 1 cm, 10 cm 떨어진 지점의 각 3지점((a) x=0, y=1, (b)x=10, y=0, (c)x=0, y=10)에서 영상을 획득한 다음 여과후역투사방법(램프필터 사용)과 3D RAMLA를 이용하여 영상재구성을 하고 FWHM을 구하였다. 민감도 측정을 위하여 선선원(F-18)을 축횡단면의 중심과 중심에서 10 cm 벗어난 지점에서 5개의 알루미늄관을 차례로 씌워 매질감쇠에 따라 달라지는 참계수를 구하고 이 값을 회귀분석하여 감쇠매질이 없는 이상적인 상황에서의 민감도를 측정하였다(랜덤계수가 참계수의 1%이내). 산란분획과 NECR을 측정하기 위하여 F-18 선선원(1110 MBq)을 산란팬텀에 주입하여 7반감기동안 계수를 획득하였다. SSRB을 사용하여 3D 데이터를 재구성한 다음 랜덤계수율이 참계수율이 1% 미만인 영역에서 산란분획을 구하고 각 횡단면의 값을 평균하여 전체 산란분획을 얻었다. 이 값을 기초로 각 프레임, 각 횡단면에 대한 랜덤계수율, 산란계수율, NECR을 구하였다. 결과: 스캐너의 중심에서 1 cm 벗어난 지점에서 횡축방향, 축방향 공간분해능은 (1) 5.3, 6.5 mm (FBP), (2) 5.1, 5.9 mm (3D RAMLA)이었다. 횡단면의 중심에서 10 cm 벗어난 지점에서 횡축반경방향, 횡축접선방향, 축방향 공간분해능은 (1) 5.7, 5.7, 7.0 mm (FBP), (2) 5.4, 5.4, 6.4 mm (3D RAMLA)이었다. 감쇠매질이 없는 이상적인 상황에서의 민감도는 횡단면의 중심에서 3,620 counts/sec/MBq, 횡단면의 중심에서 10 cm 벗어난 지점에서 4,324 counts/sec/MBq이었다. 산란분획은 40.6%, 최대 참계수율과 최대 NECR은 각각 88.9 kcps @ 12.9 kBq/mL, 34.3 kcps @ 8.84 kBq/mL이었다. 결론: 이 실험에서 NEMA NU2-2001을 이용해 GSO 섬광결정을 사용해 제작된 PET/CT에 대한 성능 평가를 실시하였다. 이는 BGO, LSO 섬광결정을 사용해 제작된 PET 스캐너의 특성과 비교할 수 있는 자료를 제공하며 PET 영상 획득 시 객관적 평가와 분석에 유용하였다.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성 (The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique)

  • 조재환;이해각;홍인식;김현주;장현철;박철수;박태남
    • 디지털콘텐츠학회 논문지
    • /
    • 제12권2호
    • /
    • pp.157-164
    • /
    • 2011
  • 유방암중 관상피내암으로 진단 받은 환자를 대상으로 조영제 주입전, 후의 감산된 영상과 3차원 재구성된 영상을 정량적으로 비교 분석하여 재구성된 영상의 효과와 유용성을 고찰 해보고자 한다. 조직학적으로 관상피 내암으로 진단 받은 환자 20명을 대상으로 3.0T MR scanner를 이용하여 감산된 영상과 3차원 재구성한 영상을 획득하였다. 분석 결과 감산 영상과 재구성한 영상에서 신호대 잡음비는 병변, 유관조직, 지방조직에서 재구성한 영상에서 높은 신호대 잡음비를 보였으며 두 영상에서의 대조 도대 잡음비는 차이를 보이지 않았다.

Determination of Epipolar Geometry for High Resolution Satellite Images

  • Noh Myoung-Jong;Cho Woosug
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.652-655
    • /
    • 2004
  • The geometry of satellite image captured by linear pushbroom scanner is different from that of frame camera image. Since the exterior orientation parameters for satellite image will vary scan line by scan line, the epipolar geometry of satellite image differs from that of frame camera image. As we know, 2D affine orientation for the epipolar image of linear pushbroom scanners system are well-established by using the collinearity equation (Testsu Ono, 1999). Also, another epipolar geometry of linear pushbroom scanner system is recently established by Habib(2002). He reported that the epipolar geometry of linear push broom satellite image is realized by parallel projection based on 2D affine models. Here, in this paper, we compared the Ono's method with Habib's method. In addition, we proposed a method that generates epipolar resampled images. For the experiment, IKONOS stereo images were used in generating epipolar images.

  • PDF

체계적인 광산관리를 위한 광산현황 및 광산공간정보 구축 기술 분석 (Analysis of the Status of Mine and Methods of Mine Geospatial Information Construction Technology for Systematic Mine Management)

  • 박준규;이근왕
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.355-361
    • /
    • 2018
  • 광업은 국가 산업발전의 기반이 되는 에너지와 원료자원을 공급하는 국가 기간산업으로 중요성을 가지고 있다. 한편 광산 개발은 필연적으로 광해를 동반하는데 대표적인 예로 지반침하, 중금속 오염, 수질오염 등을 들 수 있다. 광해는 피해의 범위가 크고, 복구에 많은 시간과 비용이 필요하며, 기간 지속적으로 피해가 발생할 수 있기 때문에 이를 방지하기 위한 체계적인 광산관리가 필요한 실정이다. 이에 본 연구에서는 국내 광산 및 광산공간정보 구축 현황과 광산관리를 위한 광산공간정보 구축 기술을 분석하였다. 조사된 광산은 95%가 비금속광으로 석회석 광산이 67%로 가장 많았으며, 구축된 광산공간정보는 2차원의 현황도 및 단면도, 지질도로 3차원 광산공간정보는 구축되어 있지 않은 것으로 나타났다. 3D 레이저 스캐너에 대한 조사 및 분석 결과와 우리나라 광산의 특징을 고려할 때 광산공간정보 구축을 위한 방안으로 이동식 스캐너가 가장 적합할 것으로 판단된다. 3D 레이저스캐너를 통해 취득되는 데이터는 대상물을 효과적으로 시각화 할 수 있으며, 갱내 도면의 제작, 체적의 산출 등 다양한 활용이 가능하기 때문에 체계적인 광산관리에 기여할 것이다.

Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study

  • Gozde, Kaya;Caglar, Bilmenoglu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.388-398
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept. MATERIALS AND METHODS. Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed. For the control group, the gypsum model was scanned 10 times with an industrial scanner. The first of the 10 virtual models obtained from the industrial model was chosen as the reference model. For trueness, the data of the 14 dental scanners were superimposed with the reference model; for precision, the data of all 14 scanners were superimposed within the groups. Statistical analyses were performed using the Kolmogorov-Smirnov, Shapiro-Wilks, and Dunn's tests. RESULTS. Primescan showed the highest trueness and precision values (P < .005), followed by the iTero 5D scanner (P < .005). CONCLUSION. Some of these digital scanners can be used to make impressions within the All-on-4 concept. However, the possibility of data loss due to artifacts, reflections, and the inability to combine the data should be considered.

한국 성인 여성의 3차원 두형개발을 위한 머리치수 연구 (An Anthropometric Study on the Korean Female Adults Heads for the Development of 3D Craniofacial Shape)

  • 김혜수;이경화;박세진
    • 한국의류학회지
    • /
    • 제29권2호
    • /
    • pp.367-378
    • /
    • 2005
  • The purpose of this study was to analyse craniofacial shape by 3D scanner for female adults with age groups. In this study, heads of 452 female adults were measured by 3D scanner. The obtained 25 measurements were analyzed by statistical methods. The results can be summarized as follows; 1. From the basic statistical data analysis, vertex-tragion and the length between the pupils were the longest in their twenties, and grew shorter in elderly groups. The length of nasion-subnasale and the width of mouth increased with an increased in age. 2. According to the analysis of the craniofacial proportions, the head type of female aduls was short-headed. The size of lower face increased with an increase in age. 3. The statistically noticeable differences were found in the measurement of the left and the right sides of face in the age groups of 20, 30, and 40. 4. High correlations were found in two perpendicular lengths, two horizontal lengths and two widths. 5. The order of factor analysis was as follows; the horizontal length, the perpendicular length and the width from highest.

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.