• Title/Summary/Keyword: 2D image marker

Search Result 47, Processing Time 0.024 seconds

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Adaptive planar vision marker composed of LED arrays for sensing under low visibility

  • Kim, Kyukwang;Hyun, Jieum;Myung, Hyun
    • Advances in robotics research
    • /
    • v.2 no.2
    • /
    • pp.141-149
    • /
    • 2018
  • In image processing and robotic applications, two-dimensional (2D) black and white patterned planar markers are widely used. However, these markers are not detectable in low visibility environment and they are not changeable. This research proposes an active and adaptive marker node, which displays 2D marker patterns using light emitting diode (LED) arrays for easier recognition in the foggy or turbid underwater environments. Because each node is made to blink at a different frequency, active LED marker nodes were distinguishable from each other from a long distance without increasing the size of the marker. We expect that the proposed system can be used in various harsh conditions where the conventional marker systems are not applicable because of low visibility issues. The proposed system is still compatible with the conventional marker as the displayed patterns are identical.

The study for improve a method of Marker auto- identification (마커 자동 인식 향상 방법에 관한 연구)

  • Lee, Hyun-Seob
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.23-38
    • /
    • 2003
  • The purpose of this study is to develop an improved marker auto-identification algorithm for reduce of data processing time through improve the efficiency of noise elimination and marker separation. The maker auto-identification algorithm was programming named KUMAS used Delphi language. For the study, various experiments were conducted for the verification of KUMAS. and compared two systems of established with the KUMAS. Four different motions - cycling, gait, rotation, and pendulum -, were selected and tested. Motions were filmed 30Hz frames rate per second. ${\chi}^2$ used for statistical analysis. Significant level were ${\alpha}=.05$. The test results were as follow. 1. Increased the success ratio of marker auto-identification. 2. The efficiency of marker auto-identification was remarkably improved through marker separation, noise elimination. 3. The marker auto-identification ability was improved in 2D-image plane include the 3D motion. 4. Significant different were found between KUMAS and B-SYS(established system) with non-input the artificial noise frames, input the artificial noise frames and total frames.

Fast Marker-based Registration of 3D CT and 2D X-ray Fluoroscopy Images (3차원 전산화 단층촬영영상과 2차원 X-선 투시영상간 표식기 기반 고속 정합)

  • Kim Gye-Hyun;Park Seong-Jin;Hong He-Len;Shin Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.3
    • /
    • pp.335-343
    • /
    • 2006
  • This paper proposes a novel technique of marker-based 2D-3D registration to combine 3D information obtained from preoperative CT images into 2D image obtained from intraoperative x-ray fluoroscopy image. Our method is divided into preoperative and intraoperative procedures. In preoperative procedure, we generate CT-derived DRRs using graphics hardware and detect markers automatically. In intraoperative procedure, we propose a hierarchical two- step registration to reduce a degree of freedom from 6-DOP to 2-DOF which is composed of in-plane registration using principal axis method and out-plane registration using minimal error searching method in spherical coordinate. For experimentation, we use cardiac phantom datasets with confirmation markers and evaluate our method in the aspects of visual inspection, accuracy and processing time. As experimental results, our method keeps accuracy and aligns very fast by reducing real-time computations.

Real-time Monitoring of the Actual Infusion Rate of Syringe Pump Using 2D Image Marker Tracking (2D 영상마커 추적 기반 시린지펌프 투약속도 실시간 감시 기술 개발)

  • Gun Ho, Kim;Young Jun, Hwang;Min Jae, Kim;Kyoung Won, Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.92-98
    • /
    • 2023
  • Purpose: To propose a new infusion rate monitoring technique based on the 2D image marker tacking to improve patient safety by preventing syringe pump-related medication accidents due to decreased infusion rate control accuracy. Materials and Methods: The infusion rate of the syringe pump and drug residue in the pump-equipped syringe were monitored in real time by tracking the movement of the 2D image markers attached to the syringe pump. Results: The error rate between the set and the estimated infusion rates was 1.03, 0.66, 1.95, 0.23, and 1.05% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. In addition, the error rate between the actual and the estimated drug residues was 1.04, 0.47, 0.60, 3.66, and 0.00% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. Conclusion: Experimental results demonstrated that the proposed technique can increase the efficiency of the safety management system for seriously ill inpatients by decreasing a possibility of syringe pump-related medication accidents in hospitals.

The Study of Stable Child English Education Content Using Augmented Reality Solving the Hide of Marker (마커의 가려짐을 해결하여 증강현실을 이용한 안정적 영어 학습 컨텐츠에 대한 연구)

  • Jeon, Soo-Jin;Kim, Young-Seop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.99-102
    • /
    • 2010
  • In this study, the 3- dimensional (3-D) learning contents are suggested using 'Augmented Reality' instead of existing 2-dimensional (2-D) learning methods. At the present, there are some 2-D learning methods using texts, image, pictures, and videos called e-learning. However, these one-way 2-D methods have some disadvantages such as declining learner's immersion and concentration. Thus, the 3-D learning contents using 'Augmented Reality' are suggested to compensate the disadvantages. According to the development of information technology (IT), the augmented reality has many applications to the era of ubiquitous. However, there are some disadvantages when learners use these contents as following; non-augmenting by partially hiding from makers and declining concentration by patterns of the makers. In this study, the beneficial marker which can solve this non-augmenting phenomenon is suggested.

Automatic Estimation of 2D Facial Muscle Parameter Using Neural Network (신경회로망을 이용한 2D 얼굴근육 파라메터의 자동인식)

  • 김동수;남기환;한준희;배철수;권오흥;나상동
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1029-1032
    • /
    • 1999
  • Muscle based face image synthesis is one of the most realistic approach to realize life-like agent in computer. Facial muscle model is composed of facial tissue elements and muscles. In this model, forces are calculated effecting facial tissue element by contraction of each muscle strength, so the combination of each muscle parameter decide a specific facial expression. Now each muscle parameter is decided on trial and error procedure comparing the sample photograph and generated image using our Muscle-Editor to generate a specific face image. In this paper, we propose the strategy of automatic estimation of facial muscle parameters from 2D marker movement using neural network. This also 3D motion estimation from 2D point or flow information in captered image under restriction of physics based face model.

  • PDF

3D Stereoscopic Augmented Reality with a Monocular Camera (단안카메라 기반 삼차원 입체영상 증강현실)

  • Rho, Seungmin;Lee, Jinwoo;Hwang, Jae-In;Kim, Junho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.3
    • /
    • pp.11-20
    • /
    • 2016
  • This paper introduces an effective method for generating 3D stereoscopic images that gives immersive 3D experiences to viewers using mobile-based binocular HMDs. Most of previous AR systems with monocular cameras have a common limitation that the same real-world images are provided to the viewer's eyes without parallax. In this paper, based on the assumption that viewers focus on the marker in the scenario of marker based AR, we recovery the binocular disparity about a camera image and a virtual object using the pose information of the marker. The basic idea is to generate the binocular disparity for real-world images and a virtual object, where the images are placed on the 2D plane in 3D defined by the pose information of the marker. For non-marker areas in the images, we apply blur effects to reduce the visual discomfort by decreasing their sharpness. Our user studies show that the proposed method for 3D stereoscopic image provides high depth feeling to viewers compared to the previous binocular AR systems. The results show that our system provides high depth feelings, high sense of reality, and visual comfort, compared to the previous binocular AR systems.

Simple Frame Marker: Implementation of In-Marker Image and Character Recognition and Tracking Method (심플 프레임 마커: 마커 내부 이미지 및 문자 패턴의 인식 및 추적 기법 구현)

  • Kim, Hye-Jin;Woo, Woon-Tack
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.558-561
    • /
    • 2009
  • In this paper, we propose Simple Frame Marker(SFMarker) to support recognition of characters and images included in a marker in augmented reality. If characters are inserted inside of marker and are recognised using Optical Character Recognition(OCR), it doesn't need marker learning process before an execution. It also reduces visual disturbance compared to 2D barcode marker due to familarity of characters. Therefore, proposed SFMarker distinguishes Square SFMarker that embeds images from Rectangle SFMarker with characters according to ratio of marker and applies different recognition algorithms. Also, in order to reduce preprocessing of character recognition, SFMarker inserts direction information in border of marker and extracts it to execute character recognition fast and correctly. Finally, since the character recognition for every frame slows down tracking speed, we increase the speed of recognition process using the result of character recognition in previous frame when frame difference is low.

  • PDF