• Title/Summary/Keyword: 2D Joints

Search Result 296, Processing Time 0.026 seconds

The Effects of Pulsator Washing Machine on Joints Torques and Muscles Strengths Considering Height of Outside Machine and Depth of Inside Drum for Average Height Users (투입구 높이 및 내부 드럼 깊이를 고려한 펄세이터 세탁기 사용시 평균신장 사용자의 관절 토크 및 근력에 미치는 영향)

  • Kim, Seong Guk;Cho, Young Kuen;Lee, Nam Gi;You, Joshua Sung Hyun;Lim, Dohyung;Kim, Han Sung;Ko, Chang-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.184-193
    • /
    • 2012
  • Many studies have reported that housework done using household appliances may affect biomechanical characteristics of the musculoskeletal system. The purpose of this study was to investigate the effects of housework done using a pulsator washing machine on joints and muscles. We calculated joint torques and muscle strengths on the basis of an experimental/virtual three-dimensional motion analysis for six healthy females using the pulsator washing machine at different heights (H) and depths (D) of the inside drum (H (mm){\times}D (mm), Trial1: $962.5{\times}609.4$, Trial2: $962.5{\times}624.4$, Trial3: $982.5{\times}644.4$, Trial4: $995.5{\times}642.4$, Trial5: $1015.5{\times}677.4$). The joint torques and muscle strengths tended to be considerably different during torso flexion in the sagittal plane for all the trials. The maximum joint torques for the thoracic vertebra, left ankle, and right shoulder measured in Trial4 were significantly higher than those measured in the other trials (p < 0.05); in addition, those for the thoracic vertebra and both ankles measured in Trial5 were significantly higher than those measured in the other trials (p < 0.05). The maximum muscle strengths for the left trapezius muscle and both tibialis anterior muscles measured in Trial5 were significantly higher than those measured in the other trials (p < 0.05). These results indicate that housework done using a pulsator washing machine may affect joint torques and muscle strengths, and these effects are dependent on the height and/or depth of the inside drum of the pulsator washing machine.

Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building (중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak;Huh, Mean-Haeng;Hong, Kun-Ho;Ha, Jae-Hoon;Nam, Young-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.453-454
    • /
    • 2009
  • In this dissertation, experimental program was carried out to study the hysteretic behavior of the reinforced different floor type interior beam-column joint repeated cyclic loads under seismic actions. The test results was as follow. The reinforced interior beam-column joint, designed by the different floor type, was increased energy dissipation capacity and maximum load carrying capacity according to the increase of different floor in comparison to standard specimen. And it was also dissimilar to failure mode adjacent to joint region. energy dissipation capacity of each specimen, designed by the different floor type, was increased 1.1${\sim}$1.35 times in comparison to standard specimen.

  • PDF

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

A Basic Study to Prepare a Watertightness Evaluation Plan for Sealant Applied to Joints Between Members of PC Structures (PC 구조물 부재간 접합부에 적용되는 실링재의 수밀성 평가방안 마련을 위한 기초적 연구)

  • Kim, Tae-Ho;Kim, Yong-Ro;Ko, Hyo-Jin;Park, Jin-Sang;Kim, Dong-Bum;Lee, Sang-Wook
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.45-56
    • /
    • 2023
  • This study was conducted to examine the feasibility of preparing a durability evaluation plan in watertightness for sealant applied to a PC structure. To this end, 5 types of sealant that equally satisfy the quality standards of the relevant KS standard were selected and tested. Through this testing, it was found that 3 of the 5 types of sealant showed deterioration in watertightness and durability, such as falling off and cracking from the substrate. For the remaining two types, a visual observation showed no significant changes, but additional analysis, confirmed that there was a large difference in the stress reduction rate of the material. Therefore, based on the above results, the need for a performance review in durability between sealant was confirmed, and based on this, the validity of the durability evaluation plan that can be used in product selection was quantitatively confirmed.

Development of 5-Axis Microscribe System for Off-Line Buffing Robot Path Programming and Its Application (버핑 로봇의 오프라인 경로 프로그래밍용 5축 마이크로스크라이브 개발 및 응용)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • We propose how to program the off-line buffing robot path along shoes' outsole shape in the footwear buffing process by a 5-axis microscribe system like robot mechanism. The microscribe system we developed consists of a 5-axis robot link with a turn table, a signal processing unit, PC and an application software program. Itmakes a robot path on the shoes' upper in accordance with the movement of a microscribe with many joints. The developed system calculates the encoder pulse values for the microscribe arm's rotation and transmits the angle pulse values to the PC through a processing unit. Denavit-Hartenberg's(D-H) direct kinematics is used to make the global coordinate from microscribe joint one. Problems with the microscribe's kinematics can be solved efficiently and systematically by D-H representation. With the coordinate values calculated by D-H equation, our system can draw a buffing gauge-line on the upper sole. We obtain shoes' outline points, which are 2 outlines coupled with the points and the normal vector based on the points. By applying the system to the buffing robot in a flexible manufacturing system, it can be used effectively to program the path of a real buffing robot.

Lateral Strength of Double-Bolt Joints to the Larix Glulam according to Bolt Spacing (볼트 간격에 따른 낙엽송 집성재 이중 볼트접합부의 전단강도)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • The lateral strength test of bending type was done to investigate the lateral capacity of the double bolt connection of domestic larix glulam according to bolt spacing. In the shear specimen, which is bolted connection in the inserted plate type, the hole of bolt was made, changing the diameter of bolt (12 mm and 16 mm), the number of bolt (single bolt : control and double bolt), the direction of bolt row (in parallel to grain : Type-A and in perpendicular to grain : Type-B) and the bolt spacing (Type-A : 4 d and 7 d and Type-B : 3 d and 5 d). Lateral capacity and failure mode of bolt connection were compared according to conditions. In prototype design (KBCS, 2000), the reduction factor of the allowable shear resistance that the bolt spacing is reduced was calculated. The results were as follows. 1) Bearing stress per bolt in the single and double bolt connection of Type-A was directly proportional to bolt diameter and bolt spacing. Bearing stress of Type-B decreased as bolt diameter was increased, and decreased by 2~10% when bolt diameter was increased. 2) In the single bolt connection and the double bolt connection of Type-A, the splitted failure was formed in the edge direction. When the bolt spacing was 3 d in Type-B, bolt was yielded more in the part of tension than in the part of compression, and the splitted failure started at the bolt in the part of tension. In the 5 d spacing specimen, the bolt in the part of tension was yielded similarly to bolt in the part of compression, and the splitted failure started in the part of compression. 3) In the prototype design, the reduction factor was calculated by non-dimensionizing the yielding load in the standard of bolt spacing (Type A : 7 d and Type B : 5 d). In 12 mm bolt connection, the reduction factor of bolt spacing 4 d (type-A) and single bolt connection was 0.87 and 0.55, respectively, and the reduction factor of bolt spacing 3 d (Type-B) and single bolt connection was 0.91 and 0.55, respectively. In 16 mm bolt connection, the reduction factor of bolt spacing 4 d (type-A) and single bolt connection was 0.96 and 0.76, respectively, and the reduction factor of bolt spacing 3 d (Type-B) and single bolt connection was 0.91 and 0.77, respectively.

Coupled analysis for the stability estimation of a subsea tunnel in discontinuous rock masses using sensitivity analysis (민감도 분석을 통한 불연속 암반 내의 해저터널의 안정성 평가를 위한 연계해석)

  • You, Kwang-Ho;Lee, Dong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.421-430
    • /
    • 2008
  • In discontinuous rock masses, hydraulic-mechanical coupled analyses are required since groundwater flow in joints have a great influence on the stability of a subsea tunnel. In this study, a sensitivity analysis was performed based on coupled analysis to verify the routine which can estimate the safety factor of a tunnel in discontinuous rock mass. To this end, 324 cases of numerical calculations were performed with a commercial program, UDEC-2D. As a result, it was confirmed that the proposed routine for coupled analysis in discontinuous rock mass could give a reasonable result for the estimation of safety factor of a tunnel. Therefore, it is expected that the safety factor estimation method used in this study can be effectively applied for the stability estimation of a subsea tunnel in discontinuous rock masses.

  • PDF

A Study on the Relationship between Dissimilar Metals Friction Welded Joints Strength Properties and Ultrasonic Reflection Coefficients (이종재 마찰용접부 강도특성과 초음파 반사계수와의 상관성에 관한 연구)

  • S. K. Oh;D. J. Kim;S. D. Han
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.34-34
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial application with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristics of the pulse echo effects according to various change in welding conditions. This paper presents a new attempt to detect the bond strength of friction welds by ultrasonic. Instead of looking for a flaw or cracks at the interface, the new approach evaluates the coefficient by reflection which provides a single quantitative indicator involving the acoustic energy reflected at the interface. The objective of this study is to find the relationship between the reflection coefficients and the weld strength. Results of the bar-to-bar friction welding of aluminum to copper and stainless steel and such relationship investigation are presented and interpreted.

Pattern of Shear-induced Fracture Development in en Echelon Array : Discrete-element Approach (전단변형 시 안행상 균열의 끝에서 형성되는 새로운 균열 발달 형태 연구 : 개별요소적 접근)

  • Kwon, Soondal;You, Seungwan;Kwon, Sanghoon;Kim, Ki-seog
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.359-372
    • /
    • 2015
  • Rock masses include various rock discontinuities such as faults, joints, and bedding planes. These discontinuities appear as complex structures in geometry. In this study, growth patterns of fractures between two stepping shear fracture tips are numerically modeled using PFC2D (Particle Flow Code). The numerical model showed not only incipient growth of fractures at the tips of preexisting fractures but also subsequent growth of the new fractures. It is observed from all of the experiments that the incipient fractures are tensile cracks developed at $30{\sim}57^{\circ}$ to the preexisting fractures and the subsequent growth of these fractures were at low angles to the preexisting fractures this study.

EFFECT OF HEPATOCYTE GROWTH FACTOR ON THE REPAIR OF DEFECT IN THE ARTICULAR DISC IN RABBIT TEMPOROMANDIBULAR JOINT (가토의 측두하악관절원판 결손에서 간세포 성장인자가 치유에 미치는 영향)

  • Kim, Bok-Joo;Seong, Hwa-Sik;Kim, Chul-Hoon;Kim, Gyoo-Cheon;Hwang, Hee-Sung;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose of this study is to investigate the therapeutic use of Hepatocyte growth factor(Adv.CMV.HGF) in temporomandibular joint disc defect. Materials and methods: Twelve New Zealand white rabbits, weighing 2.5 - 3.0 kg, were used in this experiment. Defects(2 mm in diameter) were created in their TMJ discs. Recombinant Adv.CMV.HGF with gelatin sponge($Gelfoam^{(R)}$) as carrier was implanted in the defects. We divided the rabbits into four batches according to the duration of the implantation - of 1, 4, 8, 12 weeks - and both left and right TMJ of each rabbit in all groups were used in the research : left joints were used as experiment group and right were control group. Each batch of rabbits was killed one, four, eight and twelve weeks after the experimentation respectively, and called Group A, B, C, and D. (Group A = 1 wk, B = 4 wks, C = 8 wks, and D = 12 wks) Results: The experimental group showed a significant increase in the number of chondroblasts and active cell differentiation at the margin of the defects. Compared to the control group, in the experiment group chondroblasts increased and chondrocytes showed a columnar arrangement, which is witnessed at the time of cell differentiation. Conclusion: This study supports the case that Avd.CMV.HGF may be useful in the repair of articular disc of the rabbit TMJ.