• 제목/요약/키워드: 2D GC-MS

검색결과 192건 처리시간 0.028초

Analytical Methods of Levoglucosan, a Tracer for Cellulose in Biomass Burning, by Four Different Techniques

  • Bae, Min-Suk;Lee, Ji-Yi;Kim, Yong-Pyo;Oak, Min-Ho;Shin, Ju-Seon;Lee, Kwang-Yul;Lee, Hyun-Hee;Lee, Sun-Young;Kim, Young-Joon
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권1호
    • /
    • pp.53-66
    • /
    • 2012
  • A comparison of analytical approaches for Levoglucosan ($C_6H_{10}O_5$, commonly formed from the pyrolysis of carbohydrates such as cellulose) and used for a molecular marker in biomass burning is made between the four different analytical systems. 1) Spectrothermography technique as the evaluation of thermograms of carbon using Elemental Carbon & Organic Carbon Analyzer, 2) mass spectrometry technique using Gas Chromatography/mass spectrometer (GC/MS), 3) Aerosol Mass Spectrometer (AMS) for the identification of the particle size distribution and chemical composition, and 4) two dimensional Gas Chromatography with Time of Flight mass spectrometry (GC${\times}$GC-TOFMS) for defining the signature of Levoglucosan in terms of chemical analytical process. First, a Spectrothermography, which is defined as the graphical representation of the carbon, can be measured as a function of temperature during the thermal separation process and spectrothermographic analysis. GC/MS can detect mass fragment ions of Levoglucosan characterized by its base peak at m/z 60, 73 in mass fragment-grams by methylation and m/z 217, 204 by trimethylsilylderivatives (TMS-derivatives). AMS can be used to analyze the base peak at m/z 60.021, 73.029 in mass fragment-grams with a multiple-peak Gaussian curve fit algorithm. In the analysis of TMS derivatives by GC${\times}$GC-TOFMS, it can detect m/z 73 as the base ion for the identification of Levoglucosan. It can also observe m/z 217 and 204 with existence of m/z 333. Although the ratios of m/z 217 and m/z 204 to the base ion (m/z 73) in the mass spectrum of GC${\times}$GC-TOFMS lower than those of GC/MS, Levoglucosan can be separated and characterized from D (-) +Ribose in the mixture of sugar compounds. At last, the environmental significance of Levoglucosan will be discussed with respect to the health effect to offer important opportunities for clinical and potential epidemiological research for reducing incidence of cardiovascular and respiratory diseases.

홍국쌀 에탄올 추출물과 Diacylglycerol Oil을 이용하여 제조한 기능성 유지의 이화학적 특성 연구 (Physiochemical Properties of Functional Oils Produced Using Red Yeast-Rice Ethanol Extracts and Diacylglycerol Oil)

  • 김남숙;이기택
    • 한국식품영양과학회지
    • /
    • 제36권2호
    • /
    • pp.201-208
    • /
    • 2007
  • 홍국쌀을 $35^{\circ}C$, 175 rpm에서 80% ethanol을 이용하여 0.5, 1, 2, 4, 8, 24시간 단위로 개별적으로 에탄올 추출한 결과, 1시간(yield, 1.203%) 이후의 추출 시간 증가는 추출율의 증가에 큰 영향을 미치지 않았다. 1시간 추출한 홍국쌀 에탄올 추출물을 각각 600(A), 1200(B), 1800(C), 2280(D) ppm 함유하는 기능성 유지를 제조하였다. 기능성 유지의 색도는 추출물의 함유 농도가 높아짐에 따라 $L^*$ 값이 유의적으로 감소되며, $a^*$ 값 및 $b^*$ 값은 유의적으로 증가되는 경향을 나타내었다(p<0.05). 기능성 유지의 monacolin K 및 총 페놀 함량은 추출물 첨가량의 증가에 따라 유의적으로 증가되는 경향을 보였다(p<0.05). Rancimat$(98^{\circ}C)$ 분석을 실시한 결과, 기능성 유지의 induction time이 각각 control(4.3 hr), A(3.2 hr), B(2.6 hr), C(2.4 hr), D(2.2 hr)로 추출물 첨가 농도의 증가에 따라 다소 감소하는 경향을 나타내어 산화 안정성의 보강이 필요할 것으로 판단된다. 전자코에 의해 얻어진 각 시료의 센서의 감응도$({\Delta}R/R_0)$를 이용한 주성분분석 및 MANOVA 분석 결과, 제1주성분 기여율은 99.66%로 분석되었으며 함유된 추출물의 함량 증가에 따라 각각 차별적인 향 패턴(odor difference)을 보이는 것으로 확인되었다. SPME-GC/MS에 의한 휘발성분 분석 결과, 기능성 유지에서 홍국쌀 에탄올 추출물로부터 기인되는 특유의 휘발성분은 관찰되지 않았으나, RT=12.1 min인 hexanal의 함량이 control에 비하여 유의적인 감소 경향을 나타내는 것이 확인되었다(p<0.05).

Cytotoxic Constituents of Diadema setosum

  • Minh, Chau-Van;Kiem, Phan-Van;Huong, Le-Mai;Kim, Young-Ho
    • Archives of Pharmacal Research
    • /
    • 제27권7호
    • /
    • pp.734-737
    • /
    • 2004
  • 5,8-Epidioxycholest-6-en-3-ol (1), cholesterol (2), glycerol 1-palmitate (3) and glycerol 1,3-dioleate-2-stearate (4) were isolated from the methanol extract of the sea urchin Diadema setosum, which was collected from the Halong sea, Vietnam. Chemical structures were established based on extensive 1D, 2D-NMR, FAB-MS, EI-MS spectroscopic data and GC-MS analysis. The NMR spectral data of compound 1 were reassigned by using HMQC and HMBC. Compound 1 was found to have strong cytotoxic effect against various cancer cell lines, such as KB ($IC_{50}$, 2.0 $\mu\textrm{g}$/mL), FL($IC_{50}$, 3.93 $\mu\textrm{g}$/mL), and Hep-2 ($IC_{50}$, 2.4 $\mu\textrm{g}$/mL) by in vitro assay.

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

  • Chang, Shu-Han;Ho, Hui-Yu;Zang, Chi-Zong;Hsu, Ya-Hui;Lin, Mei-Chih;Tseng, Su-Hsiang;Wang, Der-Yuan
    • Mass Spectrometry Letters
    • /
    • 제12권2호
    • /
    • pp.31-40
    • /
    • 2021
  • Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan pharmaceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography-tandem mass spectrometry (GC-MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 ㎛) and were then subjected to electron impact ionization in multiple reaction monitoring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

Headspace-GC/MS를 이용한 음료 중 벤젠 분석 (Analysis of Benzene in Beverages by Headspace-GC/MS)

  • 김은주;박상애;최동미
    • 한국식품위생안전성학회지
    • /
    • 제22권4호
    • /
    • pp.243-247
    • /
    • 2007
  • 헤드스페이스-기체크로마토그래프/질량분석기를 이용하여 음료류 중 벤젠을 분석하였다. 대상식품은 시중에 유통되는 과실쥬스 2종, 과실음료 6종, 착향탄산음료 11종, 혼합음료 55종, 추출음료 7종, 음료베이스 4종 등 총 85종이었다. 헤드스페이스의 상평형을 위하여 $40^{\circ}C$에서 30분간 교반하였으며 오븐온도는 초기 온도 $60^{\circ}C$에서 5분간 유지 후 $15^{\circ}C$/분의 비율로 $180^{\circ}C$까지 상승하였다. 내부표준물질로는 벤젠-d6을 사용하였다. 선택이온 m/z 51, 77, 78로 확인하였으며 선택이온 m/z 78에 대한 m/z 77의 반응세기비로 재검증하였다. 벤젠의 선택이온 m/z 78과 내부표준물질 벤젠-d6의 선택이온 m/z 84에 대한 피크 면적비로 정량하였다. 회수율은 $91{\sim}101%$이었으며, 정량한계는 $1{\mu}g/kg$이었다. 벤젠의 평균검출수준은 과실음료의 경우 $5{\mu}g/kg$, 착향탄산음료의 경우 $2{\mu}g/kg$, 혼합음료의 경우 $7{\mu}g/kg$, 추출음료의 경우 $7{\mu}g/kg$이었다.

미나리의 향기성분 (Analysis of the Volatile Constituents of Oenanthe stolonifera DC.)

  • 송근섭;권용주
    • 한국식품영양과학회지
    • /
    • 제19권4호
    • /
    • pp.311-314
    • /
    • 1990
  • The volatile fraction of Oenanthe stolonifera DC. was extracted by a steam distillation under the atmospheric pressure and analyzed by gas chromatography(GC) and gas chromatogra-phy/mass spectrometry(Gc-MS) The experimental results revealed the presence of 63 volatile components. Among them 39 components identified were composed of 20 hydrocarbonss(61.94%) 9 alcohols(8.76%) 3 ketones(11.5%) 1 ester(1.34%) 1 aldehyde (2.29%) and 5 miscellaneous \ulcorner92.35%) The major volatile components of Oenanthe stolonifera DC. were limo-nene(12.12%) pulegone(94.8%) germacrene D(8.34%) and $\beta$-pinene(7.68%)

  • PDF

혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단 (A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia)

  • 윤혜란;마헤샬타파
    • 대한유전성대사질환학회지
    • /
    • 제15권3호
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

티로프라미드 주사제의 생물학적 동등성 평가를 위한 GC/MS 방법 (Bioequivalence Evaluation of the Tiropramide Formulation by GC/MS)

  • 명승운;김명수;김혜영;곽현태;민혜기;손동렬;홍영훈
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.221-229
    • /
    • 2001
  • 본 연구에서는 이미 허가되어 시판되고 있는 D제약의 "티로파주"(대조약, 염산티로프라미드로서 1mL당 16.67mg 함유)와 S제약의 "티램주"(시험약)이 생물학적으로 동등한지의 여부를 판정하고자 시행되었다. 두 제제를 건강한 성인 남자 16인의 지원자에게 라틴방격법에 따라서 근육 주사한 후, 고체-액체 추출법으로 추출하여, GC/MS로 티로프라미드의 혈장 중 농도를 측정하고 이로부터 최고 혈장중 농도 (Cmax), 최고 혈장중 농도 도달시간(Tmax), 혈장중 약물농도-시간 곡선하 면적(AUC)에 대하여 식품의약품안정청(이하 식약청이라 함)과 서울대학교 약학대학이 공동 개발한 분산분석 프로그램에 의하여 분산분석을 행하였다. 정량을 위한 검정 곡선의 상관계수는 $R^2=0.998$로 좋은 직선성을 나타내었고, 검출한계는 0.1ng/mL였다.

  • PDF

Outgas 분석을 통한 MLCC Bar 변형률 측정 (Experimental Study on the Deformation of MLCC Compressed Bar by Quantitative Analysis for Outgas)

  • 김민주;김종윤;정기호;박창식
    • 한국전기전자재료학회논문지
    • /
    • 제23권6호
    • /
    • pp.458-463
    • /
    • 2010
  • MLCC (multi-layer ceramic capacitor) is usually fabricated by lamination of predetermined number of single layers. Often, the state of MLCC before sintering is called the green state, whose strength comes from the adhesion between the dielectric material and the polymer binder. Therefore the lamination of a single layer before sintering can be easily deformed by environment due to the relatively lower strength. After the compression process, which helps single sheets cohereto with adjacent sheets, the MLCC green bar is preheated to resolve the probable internal stress. Unfortunately, unexpected deformation after preheating resulted in problems during cutting of the MLCC green bar. In this study, one of 2 primary hypotheses which were proposed to resolve the unexpected deformation after preheating was examined by quantitative experiment with GC/MS (gas chromatograpy/mass spectrometer). The proportion of deformation caused by DOP evaporation, which was primarily evaporated componet during preheating, to the total deformation of the MLCC green bar was found to be 53%.