• Title/Summary/Keyword: 250 mm Depth

Search Result 65, Processing Time 0.038 seconds

1 - 5 Micron Spectra of Titan: The Spectral and Altitudinal Variation of Haze

  • Kim, Sang-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.96.2-96.2
    • /
    • 2014
  • Using solar occultation data obtained by Cassini/Visual Infrared Mapping Spectrometer (VIMS), we were able to retrieve the 1 - 5 mm optical-depth spectra of the Titanian haze, for which only selected wavelength and altitudinal ranges were previously analyzed. We found that the gross 1 - 5 mm shapes of the retrieved haze spectra are significantly different from the spectra of tholin samples in the literature. We also derived the vertical variation of the spectral structure of the $3.3-3.4{\mu}m$ absorption feature of the Titan haze from the VIMS data recorded between 250 and 700 km altitude. We found a marked change between 480 and 580 km in the relative amplitudes of the 3.33 and $3.38{\mu}m$ features which are characteristic of aromatic (double C=Cchains or rings) or aliphatic (single C-C chains) structural groups, respectively. Dicussions on this spectral and altitudinal variation will be presented.

  • PDF

First Record of Two Cold-Water Jellyfishes Aurelia limbata and Parumbrosa polylobata (Scyphozoa: Semaeostomeae: Ulmaridae) in Korean Coastal Waters

  • Chang, Soo-Jung;Kim, Jung Nyun;Yoon, Won-Duk;Ki, Jang-Seu
    • Animal Systematics, Evolution and Diversity
    • /
    • v.32 no.4
    • /
    • pp.272-280
    • /
    • 2016
  • Most scyphomedusae jellyfishes recorded in Korean waters are temperate and subtropical species. In the present study, two cold-water jellyfishes from Korean waters are first described. Scyphomedusae were collected from the coasts of Gangneung and Ulsan of the East Sea, and Boryeong, and the eastern area of the Yellow Sea from June 2006 to May 2015. Scyphomedusae collected in Ulsan and Gangneung were identified morphologically as Aurelia limbata Brandt, 1835. Their umbrella was 250-500 mm in width and 30-50 mm in height; the exumbrella was white and the subumbrella was dark brown in color. The vascular system was complex with anastomosed branches. Individuals of this species lived at about 6.6-9.9℃ and 30-50 m depth in Korean waters. Scyphomedusae collected from the center of the Yellow Sea and from Boryeong were identified as Parumbrosa polylobata Kishinouye, 1910. Their umbrella was disc-shaped, 80-200 mm in width and 20-40 mm in height. Its milky white gonads could be seen through the transparent exumbrella. The stomach cavity was round and flat with four interradial cavities connected by subgenital cavities, and the four oral arms were bifurcated and spear-head shaped. Individuals were found at about 6.4-10.0℃ and 40-90 m depth in Korean waters. The identities of both species were confirmed by molecular analysis using nuclear ribosomal DNA sequences.

Effects of Sprout Length, Amounts and Times of Nitrogen Application, Transplanting Rate and Depth of Wheat Straw Mulch on the Fall Crop Production of Potato (정식시 아장, 질소의 시용량과 시용시기, 재식거리 및 피복정도가 감자추작에 미치는 영향)

  • Jung-Hyun Choi;Jae-Young Cho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 1977
  • In order to find out the effect of five kinds of cultural treatments in fall crop production of potatoes the experiments were carried out with Simabara cultivar at Chonan in 1976. Sprouting of dormant seed pieces were induced by soaking in 2ppm GA and 250ppm Ethrel mixed solution for 60 minutes. Seed pieces with longer sprouts at transplanting, and increasing of urea(nitrogen) application from 10 to 30 Kg per 10a resulted better growth, yields, and quality. Application of total nitrogen at one time on 24th July(transplanting date) resulted lower emergence, yields, growth, and quality as compared with divided application on 24th July and 15th August and 5th September. Higher transplanting than 60$\times$20cm or 70$\times$17cm resulted slender growth and lower yields. Deeper mulch with wheat straw (from 4 to 12cm) induced lower maximal earth temperature in summer and higher minimal earth temperature in autumn.

  • PDF

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

FEA Simulations on Water Absorption in Various Pre-Cracked Concretes (유한요소해석에 기반한 콘크리트 균열 조건에 따른 수분흡수 현상 분석)

  • Kim, Kun-Soo;Park, Ki-Tae;Kim, Jaehwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.68-75
    • /
    • 2021
  • This study performed simulating water absorption in various pre-cracked concretes. 2D-Finite Element Analysis (2D-FEA) model was developed based on experimental results on the amount of absorbed water in concrete with the exposure time. Results from the 2D-FEA showed that both crack width and crack depth strongly affect the amount of absorbed water in cracked concrete. In addition, water absorption rate is introduced and a predictive equation is suggested to estimate the rate in order to quantify the amount of absorbed water in cracked concrete. It was confirmed that water absorption in concrete having less than 150 mm crack depth was dominated as a main transport factor regardless of crack width. Therefore, considering that steel corrosion caused by chlorides dissolved in water mainly occurs in reinforced concrete structures, it is necessary that crack depth as well as crack width should be investigated in reinforced concrete structures at the time of field-inspection.

A Study on the Characteristics of Heat Treated ERW Weld Seam and the Technology of Seam Annealing (고장력 강재의 전기저항 용접부 열처리 특성 및 기술에 대한 연구)

    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.133-144
    • /
    • 1999
  • To fine seam annealer capacity of through thickness seam annealing in terms of through thickness microstructure change with increased toughness and elongation leaving heat trace on it, high strength steel pipes of ERW with different thickness were tested in different seam annealing temperature measured on the outer surface of pipes. Annealing temperature and microstructure of the weld seam were changed through applied seam annealing condition. Toughness and tensile test with hardness and microstructure analysis were done on the annealed weld seam to fine its characteristics as a primary step and annealing characteristics according to different seam annealing condition. Through a study of annealed ERW weld seam characteristics and seam annealing technology, amount of electric power should apply in decreased manner to arranged inductors of annealer in the order of 1st, 2nd, 3rd, so on for proper seam annealing. For example of 15.4mm thick and 610mm outside diameter pipe, applied power for proper seam annealing is 600 -650kw at 1st inductor, 450 - 500kw at 2nd inductor, 200-250 kw at 3rd inductor of annealer during 10 - 12M/minute moving speed of pipe. Also, the penetration depth of heat trace along the thickness direction of weld during seam annealing can be estimated through the equation 17mm/kv$\times$voltage(kv) with the microstructure and hardness analysis of thick weld seam as well as study of seam annealing and comparison of cooling condition to CCT diagram of low carbon high strength steel. From this result, the difference between the technological applicability of full annealing condition based on phase diagram and full penetration of heat trace based on CCT diagram along the thickness of weld seam is discussed.

  • PDF

The Effect of Anchorage of Reinforcement in Slab-Column Connection (슬래브-기둥 접합부에서 전단보강체에 정창성능에 따른 영향)

  • Choi, Huyn-Ki;Kim, Jun-Seo;Lee, Moon-Sung;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.185-188
    • /
    • 2008
  • Flat plate system has structural weakness such as punching shear. Punching shear resistance can be increase by using a lager column section and effective depth, higer concrete compressive strength, and more flexural reinforcement ratio. But using a shear reinforcement is most economical, enable, workable solution in flat plate. The slab with thickness smaller than 250mm can not perform effectively due to insufficient development length of shear reinforcement in the slab. In case of proposed reinforcements, since the shear reinforcements were installed between the top bar and the bottom bar, shear elements generated slip failure before they reached yield. strength. effect of anchorage strength were effective anchorage length, concrete strength, diameter of shear element and anchorage detail. considering effect of slab thickness and concrete strength, formula of K factor propose in thin flat plate slab. by considering effect of anchorage length and concrete strength, strength of shear reinforcement will be computed correctly in thin flat plate slab.

  • PDF

SURFACE ROUGHNESS OF UNIVERSAL COMPOSITES AFTER POLISHING PROCEDURES (전.구치 겸용 혼합형 복합레진의 두 가지 연마법에 따른 표면조도)

  • Lee, Jae-Yong;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • The aim of this study was to evaluate the effect of two polishing methods and chemical conditioning on the surface of hybrid composites. Ninety cylindrical specimens (diameter:8mm, depth:2mm) were made with three hybrid composites-Filtek Z250, Tetric Ceram. DenFil. Specimens for each composite were randomly divided into three treatment subgroups $^{\circled1}$ Mylar strip (no treatment). $^{\circled2}$ Sof-Lex XT system, $^{\circled3}$ PoGo system. Average surface roughness(Ra) was taken using a surface profilometer at the time of setting and after immersion into 0.02N lactic acid for 1 week and 1 month. Representative specimens were examined by scanning electron microscopy. The data were analyzed using ANOVA and Scheffe's tests at 0.05% significance level. The results were as follows:1. Mylar strip resulted in smoother surface than PoGo and Sof-Lex system (p<0.001). Sof-Lex system gave the worst results. 2. Tetric Ceram was smoother than DenFil and Z250 when cured under only mylar strip. However, it was significantly rougher than other materials when polished with PoGo system. 3. All materials showed rough surface after storage in 0.02N lactic acid, except groups polished with a PoGo system. The PoGo system gave a superior polish than Sof-Lex system for the three composites. However. the correlation to clinical practice may be limited, since there are several processes. such as abrasive, fatigue, and corrosive mechanisms. Thus. further studies are needed for polishing technique under in vivo conditions.

Characteristics of Interior Space in Huizhou Traditional Houses (중국 휘주지역 전통주택의 공간구성 특성)

  • Park, Sunhee
    • Journal of the Korean housing association
    • /
    • v.26 no.6
    • /
    • pp.147-155
    • /
    • 2015
  • The purpose of this study is to understand the characteristic elements of interior space which effects the basic floor plan of traditional houses, in Huizhou, CHINA. The field study for the content analysis of a interior space of traditional houses were conducted from August 16 to 21, 2015, in Xidicun & Hongcun village. The major characteristics of 'tang' interior were as follows; Firstly, all of traditional houses in a skylight that front of 'tang'. Several types of floor plan were fixed by a combination of the space layout and numbers between 'tang' and skylights. Secondly, 'Tang' is from 3,250 to 6,000 mm in width, from 3,800 to 7,800 mm in depth. All skylights are more length than 'tang' in width. So all of spacious 'tang' were very bright without any lighting fixtutes. Thirdly, the patterns of woodcuts were the major settings of interior decorations. All of a window and door, capital has a detail woodcuts that are flowers, animals, plants, peoples, vases, and geometric patterns. In the last analysis, the traditional housing designs in Huizhoui old villages were planned for family that everlasting life, made a functional and rational decision.

SCANNING ELECTRON MICROSCOPIC STUDY OF LINK PLUS PIN IN DENTIN (상아질에 장착된 Link plus pin의 주사전자현미경적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.205-210
    • /
    • 1989
  • The purpose of this study was to observe the minim pins of Link plus (which has buttress thread and shoulder stop design) inserted into dentin and the dentin surrounding pin. The gingival walls of class II cavity were prepared with high speed handpiece in molar teeth not elapsed time after teeth were extracted, and pinhole of 2mm in depth was positioned about 1 mm to the dentinoenamel junction and minim pin was inserted with wrench. After initial examination of the specimens, the specimens were sectioned longitudinally and horizontally to the pins with carborundum disc and low speed diamond saw (Isomet Buehler Ltd) All specimens were coated Au of 250-300${\AA}$ in thickness with Ion Sputter JFC 100 and observed under Scanning Electron Microscope (JSM-35) The following results were obtained. 1. The shoulder stop was seated on the enterance of pinhole in gingival wall, and there were the irregular space between the pin and dentin at the enterance to the pin hole and flakes of dentin lifting from the dentin floor. 2. In case of section to pin horizontally or longitudinally, the dentin debris were observed in gap between pin and dentin, and small cracks were often seen in the dentin surrounding minim pins.

  • PDF