• Title/Summary/Keyword: 24-pulse

Search Result 562, Processing Time 0.028 seconds

Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor (FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포)

  • Shin, Ki-Young;Lee, Sang-Sik;Joo, Su-Bin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • Since many blood pressure pulse analyzer made to measurement of a pulse wave in quantitative way has been started, some sorts of pressure sensors are being developed. The result could differ and this cause either type of sensor or module shape, when pulse wave is measured. In this paper, calculate and compare the pressure sensor's stress distribution according to thickness of PDMS coating and existence of guide through Finite Element Method. As a result, the center of pressure sensor's stress increase as much as 24% as it is reduced as much as 0.3 mm that the PDMS coating thichness of pulse diagnostic sensor module, on the other hand the surrouding censor of center sensor's stress is reduced as much as 4.9%, and transmissive proportion of stress is small as little as 2.7%, When coating has guide.

Change in Rouleau Formation of Red Blood Cells by Pulse Magnetic Field Stimulus in the Hand (펄스자기장 자극에 의한 손의 적혈구 형태학적 변화)

  • Hwang, Do Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.1
    • /
    • pp.28-33
    • /
    • 2014
  • The change of rouleau formation of red blood cells in the hand stimulated by pulse magnetic field having a maximum intensity of 0.27 Tesla and pulse duration of 0.102 msec was investigated. Before pulse magnetic field stimulus, the red blood cells of test subject were adjoined over ten and the flow of cells was slowed. However after the stimulus in the hand during 10 minutes, the red blood cells adjoined over tens was spreaded out each other and its motion was fast. Also the red blood cells of left hand unstimulated by pulse magnetic field were spreaded out each other, even though the right hand was stimulated during 10 minute. It prove that the rouleau formation of red blood cells can be improve in the whole body in spite of stimulus in the hand because the blood is flowing a whole body.

Expansion Ratio and Ultimate Load of Pulse-Discharge Bulbed Anchors (펄스방전 그라운드 앵커의 확공특성 및 극한인발력에 관한 연구)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Joo, Yong-Sun;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.7
    • /
    • pp.5-10
    • /
    • 2009
  • The ground anchor is not usually used in soft clay and loose sand, because the pullout resistance of anchors can not be guaranteed. However, there is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which are also known as pulse discharge and electric-spark technologies. The pulse-discharge anchor has a bulbed (or underreamed) bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. In this study, in order to define a relation between expansion rate of the anchor diameter and ultimate load, anchor load tests were carried out in accordance with testing procedures by AASHTO (AASHTO 1990) and FHWA (Weatheb 1998). And then several anchors were exhumed to measure the diameter of the pulse discharge anchors.

The Effect of Taking Gamitaeeumjowee-tang for 2 Weeks on Blood Pressure, Pulse Rate and Body Weight in Overweight or Obese Patients: A Retrospective Chart Review (가미태음조위탕 2주 복용이 과체중 또는 비만 환자의 혈압, 맥박수 및 체중에 미치는 영향: 후향적 차트리뷰)

  • Soyoung Park;Min-jeong Park;Eunjoo Kim;Eunseo Kim;Young-Woo Lim
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.24 no.1
    • /
    • pp.68-75
    • /
    • 2024
  • Objectives: This study was aimed to evaluate changes in blood pressure, pulse rate and body weight of overweight or obese patients after two weeks of taking Gamitaeeumjowee-tang. Methods: A retrospective chart review was conducted for patients with auscultatory blood pressure records who visited the clinic after two weeks from the first visit between July 8, 2019 and August 30, 2019. Results: A total of seventy-two patients were included. There were significant differences in systolic blood pressure (121.69±14.3 mmHg to 117.37±12.3 mmHg, P=0.002) and pulse rate (78.56±9.3 bpm to 82.99±9.0 bpm, P<0.001). There was no significant difference in diastolic blood pressure. There were significant differences in body weight (76.28±13.5 kg to 73.41±13.1 kg, P<0.001) and body mass index (28.82±4.4 kg/m2 to 27.75±4.3 kg/m2, P<0.001). Conclusions: In this study, blood pressure tended to decrease and pulse rate slightly increased after two weeks of taking Gamitaeeumjowee-tang. It is necessary to notice the possibility of pulse rate increase and the plan of action when using Gamitaeeumjowee-tang. Additional well-designed investigations are needed.

Effects of Low Incident Energy Levels of Infrared Laser Irradiation on the Proliferation of Candida Albicans Part I : A Long Term Study according to Pulse Type

  • Sam-Kun Kim;Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 1994
  • This experiment was performed to confirm the hypothesis that LLLT had biostimulation effect for all kinds of cells and there would be differences in the growth of cells among different types of pulsed laser. 360 samples were used in this study. The samples were randomly divided in 6 groups according to the pulse type : quasi continuous type (CW), pulse 1(P1), pulse 7(P7), pulse 9(P9), pulse 15(P15) and shame-irradiated control(Co) groups. Energy fluences of all experimental groups, P1, P7, P9, P15 and CW were 2.12, 2.12, 6.37, 57.32 and 31.85 mj/cm2 respectively. All samples were irradiated for every 1 minute at 0, 12, 24, 36, 48 and 60 hours. Ten samples of each group were sacrificed at 0 and every 12 hours and then the optical density of all samples was measured with the spectrophotometer. As a result, some types of pulses showed significant differences among groups. The increase of cells were markedly stimulated with laser irradiation in P7 and P9 groups, while inhibited in CW, P1, and P15 groups compared with control group. It is therefore, suggested that specific laser pulse should be recommanded to have the biostimulation effects on the specific tissue or cells, although the biostimulation effect is does dependant.

  • PDF

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

Performance Analysis of a Pulse Separation Device for a F-type Multi-Pulse Rocket Motor (F형 다중펄스 로켓모타 적용 펄스분리장치 특성 분석)

  • Lee, Dong-Won;Lee, Won-Bok;Kim, In-Sik;Lee, Bang-Eop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.24-27
    • /
    • 2012
  • In this study, the full scale flight type Dual-Pulse Rocket Motor(DPRM) with the bulkhead type Pulse Separation Device(PSD) was designed, manufactured, and fire-tested. The bursting time and pressure of PSD were analyzed by the pressure, thrust and vibration results of static fire tests and ablation of PSD was measured with 3-D coordinate measuring machine. As a result, PSD requirements, bursting conditions and thermal safety, were satisfied.

  • PDF

High Pulse SCR Inverter for Utility Interactive Renewable Power Generation System (계통연계형 대체에너지 발전시스템을 위한 고펄스 SCR 인버터)

  • Jung, Jae-Hyuck;Kim, Hyun-Jung;Choi, Se-Wan;Kim, Young-Seok;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.85-89
    • /
    • 2001
  • In this paper, a new line-commutated SCR inverter for renewable power generation system is proposed. The proposed inverter system includes a 6-pulse SCR inverter and an auxiliary circuit. By the proper operation of the auxiliary circuit, the pulse number of the inverter system is increased and the output harmonic currents are reduced. Analysis, control and simulation for 24 pulse operation of the proposed scheme is presented and the experimental results will be provided in the final paper.

  • PDF

The effects of labeling gap and susceptibility artifacts in pCASL perfusion MRI (pCASL 관류 영상에서 표지 간격과 자화감수성 인공물이 영상에 미치는 영향)

  • Kim, Seong-Hu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.213-217
    • /
    • 2015
  • To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin Labeling) was acquired together with the structural image simply by changing position(labeling gap 15 mm, 170 mm) of the labeling pulse to avoid stent. Data was processed through the ASLtbx. When perfusion MRI was acquired using pCASL, it showed that the position of the conventional labeling pulse (labeling gap 24 mm) was overlapped with that of stent, which made signal intensity in right brain tissue appear as if it were void. When the labeling pulse was positioned (labeling gap 15 mm) to avoid stent, high signal intensity images were acquired. In labeling pulse (labeling gap 170 mm), the signal intensity was more reduced due to relaxation before labeled blood arrived at the imaging slice. pCASL can be stably repeated measurements because it does not use a contrast agent. And it should be selected with the appropriate image acquisition parameters for the high quality image.

Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet (영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구)

  • Yoon, Woo-Sung;Ji, Jong-Ok;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.179-185
    • /
    • 2014
  • The existing USB connection type of the clip-type pulsmeter equipped with a Hall sensor and a permanent magnet does not have any error or malfunction to measure the pulse wave. The property of the wireless networking system communicating the pulse wave data through the wireless LAN communication by combination USB with Ethernet and Ethernet to Wi-Fi converting system instead of existing USB connection method was investigated. There are exited that the patient needs to stay at close site of the desktop PC without USB connector and the wireless transfer and receiver networking system has pulse wave measurement SW to receive the pulse wave data. Thus it is expected that the study becomes helpful to measure and transfer the exact pulse wave of the patient in a comfortable pose at close range.