• 제목/요약/키워드: 22kV class

검색결과 93건 처리시간 0.027초

22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석 (Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable)

  • 김영석;김택희;김종민;송길목
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

Design of Main Body and Edge Termination of 100 V Class Super-junction Trench MOSFET

  • Lho, Young Hwan
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.565-569
    • /
    • 2018
  • For the conventional power MOSFET (metal-oxide semiconductor field-effect transistor) device structure, there exists a tradeoff relationship between specific on-state resistance (Ron,sp) and breakdown voltage (BV). In order to overcome this tradeoff, a super-junction (SJ) trench MOSFET (TMOSFET) structure with uniform or non-uniform doping concentration, which decreases linearly in the vertical direction from the N drift region at the bottom to the channel at the top, for an optimal design is suggested in this paper. The on-state resistance of $0.96m{\Omega}-cm2$ at the SJ TMOSFET is much less than that at the conventional power MOSFET under the same breakdown voltage of 100V. A design methodology for the edge termination is proposed to achieve the same breakdown voltage and on-state resistance as the main body of the super-junction TMOSFET by using of the SILVACO TCAD 2D device simulator, Atlas.

100 ns급 대용량 자기펄스 압축시스템의 최적화 (Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order)

  • 이용우;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.442-445
    • /
    • 2003
  • 본 연구에서는 엑시머 레이저 여기용으로 40 J급 자기펄스압축시스템(WC : magnetic pulse compression system)을 개발하고, MPC의 각단에서 최적조건을 구하였다. MPC 시스템은 DC 전원 공급기, 펄스 트랜스, 네 단의 포화인덕터로 이루어져 있다. MPC 각 단에서 포화인덕터의 회전수는 140회, 26회, 5회와 1회이며, 각단에서의 최적 용량는 각각 34 nF, 28.9 nF, 22.1 nF, 22.1 nF이다. MPC 시스템의 개선으로 우리는 43 kV의 전압, 8.25 kA의 전류와 360 ns의 펄스폭을 얻을 수 있었으며, 이때 최대 펄스 압축율은 77.7, 전류 이득은 71.7이었다.

  • PDF

What was the vSim for nursing practice experience?

  • Kim, Jungae
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권3호
    • /
    • pp.25-31
    • /
    • 2020
  • The study is a phenomenological analysis of the video simulation clinical practice experience recently conducted on nursing students due to the outbreak of corona 19 worldwide. A total of eight students participated in the vSim class who understood the purpose of the study and wanted to participate voluntarily. The data collection conducted a total of three interviews until no new data was available, and the collection period was from June 22, 2020 to July 10, 2020. The collected data were analyzed with the Giorgi's Phenomenological Analysis Method. As a result of the study, three components and 13 semantic units were derived. vSim was difficult for students, but it was an interesting experience that made them feel like nurses, and it was an experience in which they were immersed in learning rather than face-to-face classes, and their skills improved.

배전계통 적정전압 유지를 위한 유효 무효전력 협조제어 (Real and Reactive power coordination control of Distributed Generation System for Distribution Voltage Regulation)

  • 김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.153-155
    • /
    • 2000
  • This paper reveals some correlations between LDC voltage control method and the output of DGS, and also presents a method for determining the amounts of real, reactive Power of DGS for proper voltage regulation of power distribution system with LDC. Proposed method has been applied to a 22.9 kV class power distribution system, and those results show that the distribution system voltage profile is improved.

  • PDF

22.9kV 수변전설비의 실태 및 계기용변성기 절연커버의 출화특성에 관한 연구 (A Study on the Fire Properties of MOF Insulation Cover and Field Condition of 22.9kV Class Power Receiving System)

  • 최충석;김동우;한운기;이기연
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.56-60
    • /
    • 2005
  • We studied fire properties of MOF(Metering Out Fit) insulation cover and field condition of 22.9kV power receiving system. $49.5\%$ of formal equipments were installed indoors, whereas $40.8\%$ of informal equipments were installed as H-type. Insulation treatment was not done at a $22.4\%$ ratio of main line($27.7\%$ of transformer, $70.2\%$ of COS, $10.4\%$ of MOF). Fire pattern analysis showed that the fire started at the secondary part of OC wire. In the result of DTA(Differential Thermal Analysis), normal cover showed exothermic reactions at $310^{\circ}C,\;399^{\circ}C\;and\;510^{\circ}C$ (endothermic reactions at $382^{\circ}C$). Whereas damaged cover showed exothermic reactions at $412^{\circ}C$(endothermic reactions at $389^{\circ}C$). In the result of TGA(Thermo Gravimetric Analysis), the thermal weight change of normal cover was similar compared to damaged cover. In the result of FT-IR analysis, normal cover showed absorption peaks at $3,024cm^{-l},\;2,921cm^{-l},\;1,600cm^{-1},\;1,492cm^{-1},\;1,451cm^{-1},\;1,154cm^{-l},\;1,027cm^{-1},\;906cm^{-1}$. Whereas, in case of tracked cover, the absorption peaks that were shown in normal cover disappeared and different absorption peak was shown at $966cm^{-1}$.

고온초전도 케이블 단말용 cryostat 설계 (Design of Termination Cryostat for HTS Power Cable)

  • 양형석;김승현;김동락;조승연;김도형;류희석;성기철
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.160-162
    • /
    • 2003
  • Termination cryostat for 22.9kV, 1.26kA-class HTS power cable has been designed. The cryostat consists of vacuum vessel, liquid nitrogen vessel, current lead and HTS power cable. The current lead and the HTS power cable are connected in liquid nitrogen vessel cooled by forced-circulation subcooled liquid nitrogen. The maximum total heat load of this cryostat is expected to be 150w. In this paper, the detailed design of the termination cryostat is mentioned.

  • PDF

SA508 class 3 서브머지드 아크용접부의 기계적 성질에 미치는 입열량의 영향 (Effect of Heat Input on the Mechanical Properties of SA508 class 3 Steel Weldments with Submerged Arc Welding)

  • 서윤석;고진현;김남훈;오세용;주기남
    • Journal of Welding and Joining
    • /
    • 제22권5호
    • /
    • pp.38-45
    • /
    • 2004
  • The present study is to investigate the effect of heat input on the microstructure, tensile properties and toughness of single-pass submerged arc bead-in-groove welds produced on SA508 class 3 steels. The heat input was varied in the range of 1.6, 3.2 and 5.0 kJ/mm. The toughness of weld metals was evaluated by using subsize Charpy V-notch specimens in the temperature range of -19$0^{\circ}C$ to 2$0^{\circ}C$. The weld microstructure and fractography were observed by optical and scanning electron microscopies, respectively. With increasing heat inputs, tensile strength and hardness of weld metals were decreased while elongation was increased. The poor notch toughness at 1.6 kJ/mm was attributed to the formation of ferrite with aligned second phase and banitic microstructure with high yield strength while that at 5.0 kJ/mm was due to the presence of grain boundary and polygonal ferrites. The microstructure of the intermediate energy input welds consisted of a high proportion of acicular ferrite with limited polygonal ferrites, which provide improved notch toughness.

P-pillar 식각 각도에 따른 Super Junction MOSFET의 전기적 특성 분석에 관한 연구 (Electrical Characteristics of Super Junction MOSFET According to Trench Etch Angle of P-pillar)

  • 강이구
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.497-500
    • /
    • 2014
  • In this paper, we analyze electrical characteristics of n/p-pillar layer according to trench angle which is the most important characteristics of SJ MOSFET and core process. Because research target is 600 V class SJ MOSFET, so conclusively trench angle deduced 89.5 degree to implement the breakdown voltage 750 V with 30% margin rate. we found that on resistance is $22mohm{\cdot}cm^2$ and threshold voltage is 3.5 V. Moreover, depletion layer of electric field distribution also uniformly distributes.

항공사진(航空寫眞)에 의한 잣나무 임분구조(林分構造)의 추정(推定)에 관한 연구(硏究) (Studies on the Estimation of Korean Pine(Pinus koraiensis) Stand Structure by Aerial Photographs)

  • 윤종화;차두송
    • 한국산림과학회지
    • /
    • 제84권4호
    • /
    • pp.437-446
    • /
    • 1995
  • 본 논문은 강원대학교 임과대학 부속 연습림의 잣나무림(林)(I~V 영급(齡級))을 대상으로 현지조사 자료와 항공사진(航空寫眞) 측정자료와의 관계를 이용하여 영급별 흉고직경의 변동계수(變動係數), Weibull분포(分布)에 의한 ha당 본수 및 재적 등의 임분구조(林分構造)를 추정하였다. 그 결과는 다음과 같다. 1) 사진측정 수관직경으로 부터 흉고직경을 구하고 이를 단면적(斷面積) 평균목직경(平均木直徑)으로 변환하여 산출한 영급별 평균 흉고직경의 변동계수(變動係數)는 I영급 28.88%, II영급 24.13%, III영급 23.29%, IV영급 20.17% 및 V영급 18.79%이며, 2) Weibull분포에 의한 영급별(齡級別) ha당 본수(本數)는 I영급 2,875본, II영급 2,100본, III영급 1,875본, IV영급 800본 및 V영급(齡級) 325본으로 3) 영급별 ha당 재적(材積)은 I영급 $22.9m^3/ha$, II영급 $66.8m^3/ha$, III영급 $101.3m^3/ha$, IV영급 $209.6m^3/ha$ 및 V영급 $266.8m^3/ha$으로 추정되었다. 4) 따라서 임분구조 추정에 효과적으로 항공사진이 이용될 수 있을 것으로 판단된다.

  • PDF