• 제목/요약/키워드: 22.9kV distribution system

검색결과 111건 처리시간 0.025초

초전도케이블이 병입된 계통의 고장에 대한 보호협조 검토기법 (A study result on coordinative protection method of HTS cable implemented distribution system)

  • 이현철;양병모;이근준
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.700-704
    • /
    • 2011
  • This paper proposes a coordinative protection study results of 22.9kV HTS(High-Temperature Superconducting) cable implemented distribution system. HTS cable can provide about 5 times larger transfer capacability compare to conventional XLPE cable, however, it has different heat characteristic so called quench. This paper presents the simulation results on Ichun substation HTS cable which connects main transformer and 22.9kV bus. Various expected fault cases are considered and discussed to examine whether conventional protection scheme is effective to protect both of existing facilities and HTS cable. With the results of simulation, conventional protection scheme can be used if instantaneous element and time inverse elements could be adjusted with proper time coordination. Internal temperatures of HTS cable conductor in safe region with proper protection without quench. This results are to be demonstrated by the field test and will be implemented in Ichon substation HTS cable protection and control system.

22.9kV 배전선로 전력손실산출 기법에 관한 연구 (A Study on Calculation Method of Power Losses in 22.9kV Power Distribution Lines)

  • 황인성;홍순일;문종필
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.219-223
    • /
    • 2017
  • In this paper, we calculated the losses in the high voltage lines of power distribution system. The losses caused by high voltage lines are calculated using maximum current, resistance, loss factor, and dispersion loss factor. The accurate extraction of these factors are very important to calculate the losses exactly. Thus, the maximum loads are subdivided to regions and calculated monthly for more accurate maximum current calculation. Also, the composite resistance is calculated according to the ratio of the used wire types. In order to calculate the loss factor, the load factors according to the characteristics of each region were calculated. Finally, the losses of the distribution system is calculated by adding the losses by the transformers and the low voltage lines.

22.9 kV-y 실긍장 배전선로 모의를 위한 집중정수회로의 설계 (The Design of Lumped Constant Circuit for the Simulation of A Real 22.9 kV-y Distribution Line)

  • 윤철호;정영호;한용희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1186-1188
    • /
    • 1999
  • When we perform the test related to the power distribution system such as artificial fault test, protective coordination test, distribution automation test in short length test line, Lumped Constant Circuit, a kind of variable impedance, should be attached to the test line in order to make it equivalent to a real line in length electrically. In this paper we designed the positive sequence and zero sequence Lumped Constant Circuit with optimized inductor and resister for the modification of long, 16km, distribution line, when they are attached to the short, 4km, distribution test line.

  • PDF

A Study on Lightning Surges in Underground Distribution Systems

  • Jung Chae-Kyun;Kim Sang-Kuk;Lee Jong-Beom
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.171-176
    • /
    • 2005
  • The effects of surge arresters for the protection of transmission systems against direct lightning strokes have already been reviewed by many researchers. However, their studies have not encompassed underground cable systems. Therefore, in this paper we investigate the 22.9kV combined distribution systems that have arresters and ground wires. In addition, we analyze the overvoltages on underground distribution cable sections when direct lightning strokes contact the overhead ground wire using EMTP. Finally, we discuss the effect of lightning strokes according to the change of cable length and installation of arresters. This study provides insulation coordination methods for reasonable system design in 22.9kV underground distribution cable systems.

190 kVA급 초전도한류소자의 특성 (Characteristics of a 190 kVA Superconducting Fault current Limiting Element)

  • 마용호;이주영;박권배;오일성;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

배전계통 적정전압 유지를 위한 유효 무효전력 협조제어 (Real and Reactive power coordination control of Distributed Generation System for Distribution Voltage Regulation)

  • 김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.153-155
    • /
    • 2000
  • This paper reveals some correlations between LDC voltage control method and the output of DGS, and also presents a method for determining the amounts of real, reactive Power of DGS for proper voltage regulation of power distribution system with LDC. Proposed method has been applied to a 22.9 kV class power distribution system, and those results show that the distribution system voltage profile is improved.

  • PDF

반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘 (Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique)

  • 박계인;창상훈;최창규
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.71-79
    • /
    • 2008
  • 철도 고압배전선로의 경우 궤도를 따라 양방향으로 선로연변에 통신 및 신호설비와 병행하여 가공 또는 지중선로로 설치되어 있다. 가공선로의 경우에는 대기중에 노출되어 있어 뇌격, 폭풍우, 염해 등 자연현상으로 인한 고장발생이 다수 발생하고 있으며, 이에 따른 보호장치의 오 부동작이 빈번하게 발생하고 있다. 철도 고압배전선로에서 발생하는 사고 중 가장 많은 것은 1선 지락이지만 이밖에 선간 단락, 심할 경우에는 3선 지락(단락)으로까지 진전되는 사고가 있을 뿐만 아니라 단선 사고까지 발생하는 경우도 있다. 따라서 사고를 방지하기 위해서는 보다 상세한 점검보수가 필요하며, 고장발생시 조기발견과 신속한 고장처리는 철도안전수송에 중요하다. 본 논문에서는 철도 고압배전계통의 주류를 이루게 될 22.9[kV] 직접접지 계통을 대상으로 고장 발생시 고장 위치를 신속하게 표정할 수 있는 고장점 표정 알고리즘 개발을 위해 22.9[kV] 고압배전계통을 모델링 하여 특성해석과 고장해석을 수행하였고, 정확한 고장점 표정이 가능한 반복계산법을 이용한 알고리즘을 제시하였으며, 사례연구를 통해 성능을 입증하였다.

이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발 (Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution)

  • 박종훈;이한림;김찬형;김성훈;김성훈;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.42-51
    • /
    • 2015
  • 양성자 치료 시 양성자 빔을 사용하여 정밀한 치료를 수행하고 환자의 안전을 제고하기 위해서는 인체 내 양성자 빔의 선량 분포를 확인하는 것이 중요하다. 이를 위해 본 연구팀은 이전 연구에서 1차원 배열형 검출기를 종형으로 배치하여 빔 진행방향으로 이동시켜가면서 2차원적인 즉발감마선 분포를 측정하여 양성자 선량 분포와 유사한 분포를 갖는 것을 확인하였다. 본 연구에서는 이를 바탕으로 즉발감마선 이차원분포를 실시간으로 측정하기 위해 이차원 평행다공형 집속 장치, 이차원 배열의 NaI(Tl) 섬광체와 MA-PMT로 이루어진 즉발감마선 이차원분포 측정 장치를 개발하였다. 개발한 즉 발감마선 이차원분포 측정 장치의 성능을 평가한 결과 $^{22}Na$ 감마선원의 에너지 분해능은 $10.9%{\pm}0.23p%$ (0.511 MeV)와 $6.4%{\pm}0.24p%$ (1.275 MeV)로 평가되었으며, $^{137}Cs$$9.8%{\pm}0.18p%$ (0.662 MeV)로 평가되었다. 고에너지 Am-Be 선원의 double escape 피크인 3.416 MeV의 에너지 분해능은 $11.4%{\pm}3.6p%$로 평가되었다. 본 측정 장치를 이용하여 45 MeV 양성자 빔을 PMMA에 조사하여 발생한 즉발감마선 이차원분포를 측정한 결과 0.5 nA의 세기의 양성자 빔에서 $9{\times}10^9$ 양성자 조사 시 양성자 선량 분포와 유사한 즉발감마선 이차원분포를 측정할 수 있음을 확인하였다. 추가로 측정한 즉발감마선 이차원분포의 프로파일 분포를 이용하여 양성자 빔의 비정을 평가해 본 결과 $17.0{\pm}0.4mm$로 평가되었고, 실제 비정인 17.4 mm과 굉장히 밀접한 관련이 있음을 확인하였다.

배전시스템에서의 파라미터에 따른 과도현상 분석 (Transients Analysis for Parameters on Electrical Distribution System)

  • 김재철;오정환;임성정
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권3호
    • /
    • pp.88-96
    • /
    • 1997
  • 본 논문은 배전시스템에서의 파라미터에 따른 과도현상을 분석하였다. 재투입에 의한 순간전압강하와 개폐서지를 분석하였으며, 이를 위해서 22.9[kV] 배전시스템의 실 데이터를 이용하여 다중접지된 모델 시스템을 구성하였다. EMTP 시뮬레이션을 통하여 주상변압기 2차측 수용가에서의 재투입 영향을 분석하였으며, 사고선로와 인근선로에서의 과도현상을 나타냈었다. 또한 사고위치, 부하크기, 부하역률, 캐패시터뱅크의 크기, 재투입 위상각에 대한 파라미터 분석을 하였고, 이들 요소와 재투입에 의한 과도 현상과의 관계를 나타내었다.

  • PDF

22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구 (A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable)

  • 김창교;홍진수;정영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF