• Title/Summary/Keyword: 22.9kV distribution system

Search Result 111, Processing Time 0.026 seconds

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

Design of 1 MVA Single Phase HTS Transformer with Pancake Windings Cooled by Natural Convection of Sub-cooled Liquid Nitrogen

  • Kim, Woo-Seok;Kim, Sung-Hoon;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Lee, Don-Kun;Park, Yeon-Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.34-37
    • /
    • 2003
  • A 1 MVA single-phase high temperature superconducting (HTS) transformer with BSCCO-2223 wire was designed in this paper. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV respectively. Double pancake HTS windings arranged reciprocally will be used for the transformer windings, because of the advantages of insulation and distribution of surge voltage in case of a large power and high voltage transformer. Single HTS wire was used for the primary windings and four parallel wires were used for the secondary windings of the transformer with transposition. A core of the transformer was designed as a shell type core separated with the windings by a cryostat made of GFRP with a room temperature bore. The operating temperature of the HTS windings will be about 65K with sub-cooled liquid nitrogen. A cryogenic cooling system using a GM-cryocooler for this HTS transformer by natural convection of liquid nitrogen was designed. This type of cooling system can be a good option for compactness, efficiency, and reliability of the HTS transformer.

Protecting of Electrical Equipment Faults Caused by Magpie (까치에 의한 전력설비 피해방지 대책)

  • Bang, J.S.;Lee, J.S.;Park, Y.K.;Lim, K.J.;Jeong, K.H.;Choi, S.C.;Sin, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1663-1665
    • /
    • 1998
  • The power distribution system is 22.9 kV-y neutral point multi-ground one in our country. So, if conducting materials contacted, to the power line electrical equipment faults or stoppage of electrical power supply happened in the line. contacts are caused by magpie or its nest materials, especially, electrical power incidents by magpie from February to May, season layed egg, is high as 30% as. It is important to electrical power supplier to protect electrical power equipment caused by magpie. From now, KEPCO have tried to protect electrical power equipment faults caused by magpie using several methods, but have not acquired good results and continued to withdraw the nest. Recently, nature environment protection expand to around country and KEPCO also changed the nest withdrawal method to new pre-protection method coexisted with magpie, "Environmental Affinitive Pre-protection Counterplan". Therefore, we planned environmental affinitive pre-protection equipment, set test line. Also, after analyzed its effects during 1 year, we satisfied with results, and then expanded to other test lines and regions.

  • PDF

Design and Fabricate a 1 MVA Single Phase HTS Transformer with Four Parallel Pancake Windings (4병렬 팬케이크 권선을 사용한 1 MVA 단상 고온초전도 변압기의 설계 및 제작)

  • Kim, Woo-Seok;Kim, Sung-Hooon;Lee, Sang-Jin;Choi, Kyeong-Dai;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-Yop;Park, Jung-Ho;Song, Hee-Suck
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.723-725
    • /
    • 2003
  • The result of design and Partial fabrication of a 1 MVA single phase high temperature superconducting(HTS) transformer for power distributions are presented in this paper. The HTS windings are wound as double pancake windings which have advantages of uniform distribution of high voltage over the windings. the rated primary and secondary voltages are 22.9 kV and 6.6 kV respectively. Four HTS tapes are wound in parallel for secondary windings considering the rated currents of the transformer. The HTS windings will be cooled down to 65 K by natural convection of sub-cooled liquid nitrogen using a single-staged GM-cryocooler in order to make the stability of the HTS windings better. The iron core is designed as shell type and isolated from the liquid nitrogen by an FRP cryostat which have a room temperature bore. After the complete fabrication of the total HTS transformer system, performance test of the transformer will be carried out.

  • PDF

Optimal Capacitor Placement and Operation for Loss Minimzation and Improvement of Voltage Profile in Distribution System (배전계통의 손실감소 및 전압 보상을 위한 커패시터 최적 배치 및 운용)

  • 송현선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 1999
  • Ths paper presents an optimization method which determines locations and size of capacitors simultaneously while minimizing power losses and improving voltage profile in radial distribution systems. Especially, the cost function associated with capacitor pla.cerrent is considered as step function due to banks of standard discrete capacities. Genetic algorithms(GA) are used to obtain efficiently the solution of the cost function associated with capacitors which is non-continuous and non-differentiable function. The strings in GA consist of the node nwnber index and size of capacitors to be installed. The length mutation operator, which is able to change the length of strings in each generation, is used. The proposed Jrethod which determines locations and size of capacitors simultaneously can reduce power losses and improve voltage proftle with capacitors of minimum size. Its efficiency is proved through the arolication in radial distribution systems.ystems.

  • PDF

Range of physicochemical parameters for active ingredients of herbicides (제초제의 활성 성분에 대한 물리-화학 파라미터의 범위)

  • Sung, Nack-Do;Song, Seon-Seob
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.1
    • /
    • pp.58-65
    • /
    • 2003
  • Various physicochemical parameters for the active ingredients of 245 herbicides were calculated to develope a diagnosis and estimation system for utility as herbicide. The range of physico-chemical parameters for each inhibitors of photo system II (H1), acetolactate synthase (ALS) (H2) and herbicides were confirmed. The distribution ranges of 85% dependence for each physicochemical parameters were Obs.logP :$-0.90\sim4.50$, dipol moment: $1.80\sim12.22$ (debye), molecular refractivity: $53.0\sim104.0(cm^3/mol)$, polarizability: $19.0\sim37.0(\AA^3)$, HOMO energy: $-9.98\sim-7.34$ (eV), LUMO energy:$-2.76\sim0.40$ (eV), Van der Waals molecular volumes: $558.0\sim995.0(cm^3)$, molecular weight: $202.0\sim430.0$ (amu) and surface areas (Grids): $194.0\sim356.0(\AA^2)$, hydration energy: $-10.16\sim114.7$ Kcal/mol, respectively. It is suggested that MR and polarizability constants will be able to distinguish between herbicides and medicinal drugs. Results revealed that various compounds based on the range of physicochemical parameters of herbicides could be diagnosed and estimated.

Genetic Diversity in the Major Surface Protein Gene of Theileria Buffeli in Korean Indigenous Cattle (국내 한우의 타일레리아 주요항원단백질 유전자의 다양성)

  • Yu, Do-Hyeon;Li, Ying-Hua;Chae, Joon-Seok;Park, Jin-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.501-507
    • /
    • 2010
  • The aim of the current study was to analyze the diversity of the major surface protein (Msp) gene in Theileria buffeli, which is known as the major antigenic protein recognized by the immune system of the host. In addition, we characterized the diversification of the Msp gene and its relationship to with the pathogenicity of Theileria. Complete blood counts (CBC) and Theileria 18S rRNA PCR sequence analysis were performed for 177 Korean indigenous cattle (KIC) in Jeju Island. A total of 28 KIC (16 anemic and 12 non-anemic KIC) were then randomly selected based on 18s rRNA PCR positive samples for sequence analysis of the Theileria Msp gene, which was performed twice for each specimen. The resulting 56 Msp gene sequences were classified into five antigenicity types (type I to V), according to the variable region (517-571 bp), which exhibited high similarity (${\geq}$ 98.9%) to several available GenBank sequences (Theileria spp. from China-EU584237; T. sergenti from China-DQ078264; Theileria spp. from Thailand-AB081329; Theileria spp. from Japan-AB218442; T. sergenti from Japan-AB016280). The 56 Msp sequences consisted of 22, 15, 9, 8, and 2 cases of type I to type V Msp genes, respectively. The most prevalent type in both anemic and non-anemic KIC was type I (37.5% in anemic and 41.7% in non-anemic). Among the remaining types, type II was the most prevalent (37.5%) in anemic KIC, while type IV was the most prevalent (25%) in non-anemic KIC. The results of our study help confirm the diversity of Msp gene types and demonstrate that the gene type distribution of Msp genes varies among Theileria-infected KIC in Jeju Island.

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

Effect of Trichostatin A on Anti HepG2 Liver Carcinoma Cells: Inhibition of HDAC Activity and Activation of Wnt/β-Catenin Signaling

  • Shi, Qing-Qiang;Zuo, Guo-Wei;Feng, Zi-Qiang;Zhao, Lv-Cui;Luo, Lian;You, Zhi-Mei;Li, Dang-Yang;Xia, Jing;Li, Jing;Chen, Di-Long
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7849-7855
    • /
    • 2014
  • Purpose: To investigate the effect of deacetylase inhibitory trichostatin A (TSA) on anti HepG2 liver carcinoma cells and explore the underlying mechanisms. Materials and Methods: HepG2 cells exposed to different concentrations of TSA for 24, 48, or 72h were examined for cell growth inhibition using CCK8, changes in cell cycle distribution with flow cytometry, cell apoptosis with annexin V-FTIC/PI double staining, and cell morphology changes under an inverted microscope. Expression of ${\beta}$-catenin, HDAC1, HDAC3, H3K9, CyclinD1 and Bax proteins was tested by Western blotting. Gene expression for ${\beta}$-catenin, HDAC1and HDAC3 was tested by q-PCR. ${\beta}$-catenin and H3K9 proteins were also tested by immunofluorescence. Activity of Renilla luciferase (pTCF/LEF-luc) was assessed using the Luciferase Reporter Assay system reagent. The activity of total HDACs was detected with a HDACs colorimetric kit. Results: Exposure to TSA caused significant dose-and time-dependent inhibition of HepG2 cell proliferation (p<0.05) and resulted in increased cell percentages in G0/G1 and G2/M phases and decrease in the S phase. The apoptotic index in the control group was $6.22{\pm}0.25%$, which increased to $7.17{\pm}0.20%$ and $18.1{\pm}0.42%$ in the treatment group. Exposure to 250 and 500nmol/L TSA also caused cell morphology changes with numerous floating cells. Expression of ${\beta}$-catenin, H3K9and Bax proteins was significantly increased, expression levels of CyclinD1, HDAC1, HDAC3 were decreased. Expression of ${\beta}$-catenin at the genetic level was significantly increased, with no significant difference in HDAC1and HDAC3 genes. In the cytoplasm, expression of ${\beta}$-catenin fluorescence protein was not obvious changed and in the nucleus, small amounts of green fluorescence were observed. H3K9 fluorescence protein were increased. Expression levels of the transcription factor TCF werealso increased in HepG2 cells following induction by TSA, whikle the activity of total HDACs was decreased. Conclusions: TSA inhibits HDAC activity, promotes histone acetylation, and activates Wnt/${\beta}$-catenin signaling to inhibit proliferation of HepG2 cell, arrest cell cycling and induce apoptosis.