• 제목/요약/키워드: 22.9kV XLPE cable

검색결과 39건 처리시간 0.027초

22.9kV 트리억제형 전력케이블의 성능평가 (Efficiency appraisal of 22.9kV tree retardant power cable)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

22-9kV급 XLPE 시이트의 유전특성과 계면효과 (Interface Effects and Dielectric Properties of 22.9kV XLPE sheets)

  • 이관우;이종복;황보승;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.441-444
    • /
    • 2000
  • In this paper, dielectric properties of XLPE sheets of 22kV cable with semiconducting and water were investigated. The breakdown strength of XLPE under rod/needle electrode were measured at without oil. It is found that the dielectric properties such tan$\delta$ of XLPE sheet dependence on semiconducting and water layer and are decreased much lower increase with temperature. The breakdown strength and the electrode effect are obtained as a function of thickness, and a equation for the sheet thickness dependent breakdown strength is also discussion.

  • PDF

XLPE 케이블의 전기적 열화 패턴 분석 (Electrical Degradation Pattern Analysis according to XLPE Cable)

  • 민치현;곽동순;천현권;최진욱;김영석;김선구;김상현
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.114-120
    • /
    • 2008
  • 일반적으로 22.9[kV] 이하의 케이블은 가교폴리에틸렌(XLPE)을 절연체로 사용하고 있다. XLPE내부의 결함으로 인한 사고로 경제적 및 인명피해가 발생한다. 이러한 사고에 대한 처리 기준이 마련이 되어 있지 않아 사고처리의 체계화가 시급히 필요한 실정이다. 본 연구에서는 XLPE 케이블의 사고 요인이 되는 전기적 열화현상에 대한 자료구축을 위하여 XLPE에 곡율반경이 $10[{\mu}m]$인 침천극을 삽입하여 절연파괴, 트리형상 및 연면방전 시료를 제작하였다. 단시간 파괴는 AC 60[Hz]의 전압을 1[kV/sec] 상승하였으며, 장기과전의 경우 AC 60[Hz]의 전압을 12[kV] 및 17[kV]를 인가하여 전기적 열화 특성에 대하여 실험을 하였다.

22.9[kV]이하 XLPE 전력케이블의 열 충격 시험 및 절연파괴 특성 (The Properties of Dielectric Breakdown and Thermal Stresses below 22.9[kV] Class XLPE Power Cable)

  • 김영석;송길목;김선구
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.54-60
    • /
    • 2008
  • 2002년부터 시행되어오고 있는 제조물 책임법에 의해 사고케이블의 원인분석과 사고패턴에 대한 데이터베이스화가 중요하다. 더욱이 가속열화상태에서 전력케이블 사고의 패턴 및 모의실험은 데이터베이스 시스템 구축에 필요하다. 본 논문에서는 열 열화 따른 22.9[kV]이하 케이블의 열 충격시험을 수행하였다. 이 시험은 IEC60811-3-1에 따른다. 시험결과로부터, 22.9[kV]급 A사 전력케이블은 표면이 변색되었고 길이방향으로 급격하게 감소되었다. 특히, A사 전력케이블의 열 중량 특성이 심하게 변함에 따라, 케이블 제조상의 문제일 것이라 추측된다. 만약 전력케이블의 제조상의 결함에 의한 것이라면, 피해자들은 PL환경 하에 손해배상을 받을 수 있을 것이다.

XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토 (A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation)

  • 강동식;선종호;이홍식;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권7호
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.

22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석 (Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable)

  • 김영석;김택희;김종민;송길목
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

전력용 XLPE Cable의 부분방전과 방사전자파 특성 (Characteristics of Radiated Electromagnetic Wave and Partial Discharge in Power XLPE Cable)

  • 이광식;이현철;박광서;윤대희;이상훈;김종환;김충년;김기채
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.90-95
    • /
    • 2004
  • 본 논문은 XLPE(cross-linked polyethylene insulated power Cables)을 절연물로 사용하는 22.9[kV]용 전력케이블에 외부 손상에 의해 발생되는 부분 방전을 모의하였으며, 절연 진단방법 중 하나인 UHF법을 이용하여 부분 방전시 공간으로 전파되는 방사전자파을 EMI, EMC 측정용 BiconiLog 안테나(EMCO 3142)와 스펙트럼 아날라이저를 이용해 측정하는 UHF법을 이용하였다. 본 연구 결과 방전진전과정의 평가가 가능함을 확인하였다.

14주기 열화 및 AWTT에 따른 22.9kV TR CNCV-W 전력케이블의 교류파괴전압 특성분석 (AC Breakdown Voltage Characteristics of 22.9kV TR XLPE Power Cable Before and After 14days Cyclic Aging and AWTT)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1507-1508
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시하며, XLPE 절연체에 발생하는 수트리를 가속 발생 성장시킬 목적으로 가속수트리 열화를 실시한다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후, 120, 240, 360일 가속수트리(AWTT) 후의 파괴전압을 분석하였다. 14주기노화는 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났으며, 240일 AWTT 이후에 노화가 가속되는 것으로 나타났다.

  • PDF

14주기 열화에 따른 22.9kV 전력케이블의 교류파괴전압 특성분석 (AC Breakdown Voltage Characteristics for 22.9kV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2271-2273
    • /
    • 2005
  • The cyclic aging for 14days is performed in order to remove the large amount of the volatiles contained in freshly manufactured cable. And the accelerated water treeing test(AWTT) is performed to accelerate the occurance of the water tree in the dielectric of XLPE. In this paper, we examined the AC breakdown voltage characteristics of the 22.9kV power cable before and after the cyclic aging for 14days and the AWTT. As the result, the AC breakdown voltage of the TR CNCV-W power cable is higher than that of CNCV-W and FR CNCO-W power cable.

  • PDF