• Title/Summary/Keyword: 2-electrodes EEG

Search Result 53, Processing Time 0.02 seconds

Does a Frontal 2-Electrode Electroencephalogram Provide Sufficient Neuropsychological Information in Various Major Psychiatric Disorders?

  • Sol Han;Hyen-Ho Hwang;Kang-Min Choi;Sungkean Kim;Seung-Hwan Lee
    • Anxiety and mood
    • /
    • v.20 no.1
    • /
    • pp.8-16
    • /
    • 2024
  • Objective : The purpose of this study is to compare the signal obtained from the frontal 2-electrodes EEG with that obtained from the temporal, central, and parietal 2 electrodes. Methods : EEGs were recorded in a total of 67 patients with major depressive disorder (MDD), 104 patients with schizophrenia (SCZ), and 29 patients with Alzheimer's disease (AD). For each disease group, there were healthy controls (HC) that were paired accordingly (HC1=69, HC2=104, HC3=27). The following measurements were compared across electrodes: band power, alpha peak frequency (APF), APF power, alpha asymmetry (AA), and Kolmogorov complexity (KC). Results : Statistically significant differences were found in band power measured from frontal electrodes compared to electrodes placed in other locations. Specifically, the power of theta waves was measured higher in the temporal electorodes, alpha 1 and alpha 2 waves in the parietal, beta 1 and beta 2 in the central, and gamma waves in the temporal electrodes. Both SCZ and AD patients showed increased theta power in all electrodes. In SCZ patients, APF decreased in the central and temporal electrodes, but the APF power analysis showed no difference between the patients and controls. Additionally, AD patients exhibited increased AA in the central EEG, while SCZ patients showed decreased KC in the parietal and temporal electrodes. Conclusion : Depending on the electrode location, sensitive EEG frequencies differed. Compared with signals from other electrodes, frontal EEG in MDD patients revealed generally constant signal values, though the temporo-parieto-central electrodes appeared to be more reliable in SCZ and AD patients.

A Study on Gel-free Probe for Detecting EEG (뇌파 탐지용 Gel-free probe 연구)

  • Yun, Dae-Jhoong;Eum, Nyeon-Sik;Jeong, Myung-Yung
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.156-166
    • /
    • 2012
  • Over the past 15 years productive BCI research programs have arisen. Current mainstream EEG electrode setups permit efficient recordings but most of electrodes has the disadventages of need for skin preparation and gel application to correctly record signals. The new gel-free probe was adapted for EEG recording and it can be fixed to the scalp with the micro needle without neuro-gel. It use standard EEG cap for wearing electrodes on scalp so it is compatible with standard EEG electrodes. A comparison between electrode characteristics is achieved by performing simultaneous recordings with the gel electrodes and gel-free probe placed in parallel scalp positions on the same anatomical regions. The quality of EEG recordings for all two types of experimental conditions is similar for gel-electrodes and gel-free probe. Subjects also reported not having special tactile sensations associated with wearing of gel-free probes. According to our results, it is expected that gel-free probe can be adapted to BCI, BMI(Brain Machine Interface), HMI(Human Machine Interface) because of its simple application and comfortable wearing process.

32-Channel EEG and Evoked Potential Mapping System (32채널 뇌파 및 뇌유전발전위 Mapping 시스템)

  • 안창범;박대준
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.179-188
    • /
    • 1996
  • A clinically oriented 32-channel electroencephalogram (EEG) and evoked potential (EP) mapping system has been developed EEG and EP signals acquired from 32-channel electrodes attached on the heroid surface are amplified by a pre-amplifier which is separated from main amplifier and is located near the patient to reduce signal attenuation and noise contamination between electrodes and the amplifier. The amplified signals are further amplified by a main amplifier where various filtering and gain contr61 are achieved An automatic artifact rejection scheme is employed using neural network-based EEG and artifact classifier, by which examination time is substantially reduce4 The continuously measured EEG sigrlals are used for spectral mapping, and auditory and visual evoked potentials measured in synchronous to the auditory and visual stimuli are used for temporal evoked potential mapping. A user-friendly graphical interface based on the Microsoft Window 3.1 is developed for the operation of the system. Statistical databases for comparisons of group and individual are included to support a statistically-based diagnosis.

  • PDF

Pharmacodynamic Interactions of Diazepam and Flumazenil on Cortical Eeg in Rats (흰쥐 대뇌피질의 뇌파에 대한 diazepam 및 flumazenil의 약력학적 상호작용)

  • 이만기
    • Biomolecules & Therapeutics
    • /
    • v.7 no.3
    • /
    • pp.242-248
    • /
    • 1999
  • Diazepam, a benzodiazepine (BDZ) agonist, produces sedation and flumazenil, a BDZ antagonist, blocks these actions. The aim of this study was to examine the effects of BDZs on cortical electroencephalogram (EEG) in rats. The recording electrodes were implanted over the frontal and parietal cortices bilaterally, and the reference and ground electrodes over cerebellum under ketamine anesthesia. To assess the effects of diazepam and flumazenil, rats were injected with diazepam (1 mgHg, i.p.) and/or flumazenil ( 1 mg/kg, i.p.), and the EEG was recorded before and after drugs. Normal awake had theta peak in the spectrum and low amplitude waves, while normal sleep showed large amplitude of slow waves. The powers of delta, theta and alpha bands were increased during sleep compared with during awake. Diazepam reduced the mobility of the rat and induced sleep with intermittent fast spindles and large amplitude of slow activity, and it produced broad peak over betaL band and increased the power of gamma band, which were different from EEG patterns in normal sleep. Saline injection awakened rats and abolished fast spindles for a short period about 2-5 min from EEG pattern during diazepam-induced sleep. Flumazenil blocked both diazepam-induced sleep and decreased the slow activities of delta, theta, alpha and betaL, but not of gamma activity for about 10 min or more. This study may indicate that decrease in power of betaL and betaH bands can be used as the measure of central action of benzodiazepines, and that the EEG parameters of benzodiazepines have to be measured without control over the behavioral state by experimenter.

  • PDF

A Study on Applicability of EEG Spectral Relative Power as a Measure of Expertise Level (뇌파 상대 스펙트럼의 숙련도 평가 척도로의 이용 가능성에 대한 연구)

  • Ok, Dong-Min;Park, Hee-Sok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.5
    • /
    • pp.741-750
    • /
    • 2010
  • The objective of this paper is to study if the EEG spectral relative power would be a reasonable measure of expertise level. EEG electrodes were placed on the locations of Fp1, Fp2, F3, F4, T3, T4, O1, O2 while 5 subjects were playing 4 kinds of game on PC. EEG spectral relative power was significantly related with expertise level on the locations of Fp1, T3, T4, O1, O2. And the results showed that the $\theta$ and $\alpha$ activities were decreased, while $\beta$ and $\gamma$ activities were increased. The results indicated that the EEG spectral relative power would be applicable as a quantitative measure of expertise level.

Fundamental requirements for performing electroencephalography

  • Koo, Dae Lim;Kim, Won-Joo;Lee, Sang-Ahm;Kim, Jae Moon;Kim, Juhan;Park, Soochul;Korean Society of Clinical Neurophysiology Education Committee
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.113-117
    • /
    • 2017
  • The performance of electroencephalogram (EEG) recordings is affected by electrode type, electronic parameters such as filtering, amplification, signal conversion, data storage; and environmental conditions. However, no single method has been identified for optimal EEG recording quality in all situations. Therefore, we aimed to provide general principles for EEG electrode selection as well as electronic noise reduction, and to present comprehensive information regarding the acquisition of satisfactory EEG signals. The standards provided in this document may be regarded as Korean guidelines for the clinical recording of EEG data. The equipment, types and nomenclature of electrodes, and the details for EEG recording are discussed.

Comparison of EEG Characteristics between Dementia Patient and Normal Person Using Frequency Analysis Method (주파수분석법에 의한 치매환자와 정상인의 뇌파특성 비교)

  • Jang, Yun-Seok;Park, Kyu-Chil;Han, Dong-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.595-600
    • /
    • 2014
  • Nowadays our society is rapidly transforming into an aging society. A better understanding of dementia is a high priority in the aging society. Therefore our study is basically aimed at understanding characteristics of EEG signals from dementia patients. Firstly, we analyzed spontaneous EEG signals from normal persons and dementia patients to distinguish their characteristics. The EEG signals are recorded with 16 electrodes and we classified the EEG signals form the signals according to frequency band. To obtain the clean EEG signals, we used cross correlation function between two channels. From the analysis results, we can observe that the EEG characteristics from dementia patients are distinctly different from that from normal persons.

Spray coating of electrochemically exfoliated graphene/conducting polymer hybrid electrode for organic field effect transistor

  • Kim, Youn;Kwon, Yeon Ju;Hong, Jin-Yong;Park, Minwoo;Lee, Cheol Jin;Lee, Jea Uk
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.399-405
    • /
    • 2018
  • We report the fabrication of organic field-effect transistors (OFETs) via spray coating of electrochemically exfoliated graphene (EEG) and conducting polymer hybrid as electrodes. To reduce the roughness and sheet resistance of the EEG electrodes, subsequent coating of conducting polymer (poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS)) and acid treatment was performed. After that, active channel layer was developed by spin coating of semiconducting poly(3-hexylthiophene) on the hybrid electrodes to define the bottom gate bottom contact configuration. The OFET devices with the EEG/PEDOT:PSS hybrid electrodes showed a reasonable electrical performances (field effect mobility = $0.15cm^2V^{-1}\;s^{-1}$, on/off current ratio = $10^2$, and threshold voltage = -1.57V). Furthermore, the flexible OFET devices based on the Polydimethlsiloxane (PDMS) substrate and ion gel dielectric layer exhibited higher electrical performances (field effect mobility = $6.32cm^2V^{-1}\;s^{-1}$, on/off current ratio = $10^3$, and threshold voltage = -1.06V) and excellent electrical stability until 1000 cycles of bending test, which means that the hybrid electrode is applicable to various organic electronic devices, such as flexible OFETs, supercapacitors, organic sensors, and actuators.

Automatic EEG and Artifact Classification Using Neural Network (신경망을 사용한 뇌파 및 Artifact 자동 분류)

  • Ahn, Chang-Beom;Lee, Taek-Yong;Lee, Sung-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.157-166
    • /
    • 1995
  • The Electroencephalogram (EEG) and evoked potential (EP) t;ave widely been used for study of brain functions. The EEG and EP signals acquired from multi-channel electrodes placed on the head surface are often interfered by other relatively large physiological signals such as electromyogram (EMG) or electroculogram (EOG). Since these artifact-affected EEG signals degrade EEG mapping, the removal of the artifact-affected EEGs is one of the key elements in neuro-functional mapping. Conventionally this task has been carried out by human experts spending lots of examination time. In this paper a neural-network based classification is proposed to replace or to reduce human expert's efforts and time. From experiments, the neural-network based classification performs as good as human experts : variation of decisions between the neural network and human expert appears even smaller than that between human experts.

  • PDF

Development of an Active Dry EEG Electrode Using an Impedance-Converting Circuit (임피던스 변환 회로를 이용한 건식능동뇌파전극 개발)

  • Ko, Deok-Won;Lee, Gwan-Taek;Kim, Sung-Min;Lee, Chany;Jung, Young-Jin;Im, Chang-Hwan;Jung, Ki-Young
    • Annals of Clinical Neurophysiology
    • /
    • v.13 no.2
    • /
    • pp.80-86
    • /
    • 2011
  • Background: A dry-type electrode is an alternative to the conventional wet-type electrode, because it can be applied without any skin preparation, such as a conductive electrolyte. However, because a dry-type electrode without electrolyte has high electrode-to-skin impedance, an impedance-converting amplifier is typically used to minimize the distortion of the bioelectric signal. In this study, we developed an active dry electroencephalography (EEG) electrode using an impedance converter, and compared its performance with a conventional Ag/AgCl EEG electrode. Methods: We developed an active dry electrode with an impedance converter using a chopper-stabilized operational amplifier. Two electrodes, a conventional Ag/AgCl electrode and our active electrode, were used to acquire EEG signals simultaneously, and the performance was tested in terms of (1) the electrode impedance, (2) raw data quality, and (3) the robustness of any artifacts. Results: The contact impedance of the developed electrode was lower than that of the Ag/AgCl electrode ($0.3{\pm}0.1$ vs. $2.7{\pm}0.7\;k{\Omega}$, respectively). The EEG signal and power spectrum were similar for both electrodes. Additionally, our electrode had a lower 60-Hz component than the Ag/AgCl electrode (16.64 vs. 24.33 dB, respectively). The change in potential of the developed electrode with a physical stimulus was lower than for the Ag/AgCl electrode ($58.7{\pm}30.6$ vs. $81.0{\pm}19.1\;{\mu}V$, respectively), and the difference was close to statistical significance (P=0.07). Conclusions: Our electrode can be used to replace Ag/AgCl electrodes, when EEG recording is emergently required, such as in emergency rooms or in intensive care units.