• Title/Summary/Keyword: 2-dimensional measurement

Search Result 921, Processing Time 0.025 seconds

A Study on the Measurement of the Breast Shape on Living Body by Using a PMP Moire Method (가슴형상 측정을 위한 PMP Moire 방법 활용)

  • Lee, Ga-Na;Yuk, Keun-Cheol;Kim, Byeong-Mee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.11-21
    • /
    • 2009
  • Recently, as custom-made demand about female underwear is increased, securing of a various dimension system is urgent, and satisfaction of each customer cannot be heightened with established dimensions. If we could measure shape of a living body with a fast and simple method, the custom-made demand of customers could be satisfied in the underwear as well as a clothing industry by using the method. One of the alternatives is shape measurement of the living body by a Moire fringe method. If we put a grating in front of an object to be measured and illuminate light, a Moire fringe with contour line shape is generated in the object, so we can conveniently measure object shape without touching directly by using the pattern. The Moire fringe and three-dimensional shape of the breast of the living body was acquired by a PMP method using a polygon mirror, and height and bottom width of the breast of the living body were measured by using obtained data in this study. Data of breast shape measurement through a mannequin was collected in a previous step as basic material for measuring the breast shape measurement of the living body. Three women in the twenties were selected as one of methods for measuring breast shape of a woman. As a result of the breast shape measurement of a living body A, it was measured that height of the breast was about 67.24mm and the bottom width was $13781.60mm^2$. This study is expected to contribute for collecting basic data of a female underwear industry and establishing a specification of a dimension system.

  • PDF

Fabrication and Characterization of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry (고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Shin, Sang-Hun;Kim, Hyung-Shik;Yi, Jeong-Han;Lee, Bong-Soo;Kim, Sin;Cho, Hyo-Sung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.241-245
    • /
    • 2007
  • In this study, a two-dimensional fiber-optic radiation sensor has been developed using water-equivalent organic scintillators for photon beam therapy dosimetry. Two-dimensional photon beam distributions and percent depth doses(PDD) are measured according to the energies and field sizes of the photon beam. This sensor has many advantages such as high resolution, real-time measurement and ease of calibration over conventional radiation measurement devices.

High-speed Three-dimensional Surface Profile Measurement with the HiLo Optical Imaging Technique

  • Kang, Sewon;Ryu, Inkeon;Kim, Daekeun;Kauh, Sang Ken
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.568-575
    • /
    • 2018
  • Various techniques to measure the three-dimensional (3D) surface profile of a 3D micro- or nanostructure have been proposed. However, it is difficult to apply such techniques directly to industrial uses because most of them are relatively slow, unreliable, and expensive. The HiLo optical imaging technique, which was recently introduced in the field of fluorescence imaging, is a promising wide-field imaging technique capable of high-speed imaging with a simple optical configuration. It has not been used in measuring a 3D surface profile although confocal microscopy originally developed for fluorescence imaging has been adapted to the field of 3D optical measurement for a long time. In this paper, to the best of our knowledge, the HiLo optical imaging technique for measuring a 3D surface profile is proposed for the first time. Its optical configuration and algorithm for a precisely detecting surface position are designed, optimized, and implemented. Optical performance for several 3D microscale structures is evaluated, and it is confirmed that the capability of measuring a 3D surface profile with HiLo optical imaging technique is comparable to that with confocal microscopy.

Adaptability of one-dimensional analysis for the flow distribution of a complex duct system (복합 덕트시스템의 유량분배에 관한 1차원 해석의 적합성)

  • 이승철;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.579-587
    • /
    • 1999
  • The flow distribution characteristics in a complex duct system have been investigated in this paper by three means, namely experimental measurement, numerical simulation and the Extended T-method analysis. While the exit flow rates predicted by the three-dimensional CFD calculation and those given by the experiment show a close agreement, the results from the one-dimensional Extended T-method are found to differ from the experiment by -22.2% to 26.3% for the various exits. These discrepancies may be attributed to the underlying limitation concerning the fitting loss coefficients, which assume that the flow in front of the fittings is fully developed. It is proposed that, in order to analyse the three-dimensional flow distributions in a complex duct system by one-dimensional analysis such as the Extended T-method, further Improvements to the fitting loss coefficients should be made.

  • PDF

Electron Transport of Low Transmission Barrier between Ferromagnet and Two-Dimensional Electron Gas (2DEG)

  • Koo, H.C.;Yi, Hyun-Jung;Ko, J.B.;Song, J.D.;Chang, Joon-Yeon;Han, S.H.
    • Journal of Magnetics
    • /
    • v.10 no.2
    • /
    • pp.66-70
    • /
    • 2005
  • The junction properties between the ferromagnet (FM) and two-dimensional electron gas (2DEG) system are crucial to develop spin electronic devices. Two types of 2DEG layer, InAs and GaAs channel heterostructures, are fabricated to compare the junction properties of the two systems. InAs-based 2DEG layer with low trans-mission barrier contacts FM and shows ohmic behavior. GaAs-based 2DEG layer with $Al_2O_3$ tunneling layer is also prepared. During heat treatment at the furnace, arsenic gas was evaporated and top AlAs layer was converted to aluminum oxide layer. This new method of forming spin injection barrier on 2DEG system is very efficient to obtain tunneling behavior. In the potentiometric measurement, spin-orbit coupling of 2DEG layer is observed in the interface between FM and InAs channel 2DEG layers, which proves the efficient junction property of spin injection barrier.

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

TAH(Total Artificial Heart) Fitting Trial Supported by 4D Volume Visualization Technique (4차원 체적 가시화 기법을 이용한 인공심장의 Fitting Trial)

  • Lee, Dong-Hyuk;Kim, Jong-Hyo;Min, Byong-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.161-162
    • /
    • 1997
  • It is very useful to perform the surgery simulation before implanting TAH(Total Artificial Heart} in a patient. The space of chest and the shape of vessels are different from patient to patient. So, It is desirable to customize a TAH design to the anatomy structure of a patient. Several studies are performed to visualize and explain the 3D structure of heart. These studies are performed using 2-dimensional ref or mated images and simple measurement. Anatomy structure of a human heart is not so simple. It is 4dimensional structure ; 3-dimensional plus time, heart beating. 3-dimensional reconstruction schemes of medical images developed for about 10 years are usually categorized into two types of rendering technique ; surface rendering and volume rendering. Volume rendering is preferable in medical image processing field because this technique can be applied without considering the complexity of geometry and change of field of interest. The usable space in the chest of patient can be measured by 3D volume matching of patient trunk and TAH model. This space changes with time. In this research we have developed the 4-dimensional volume match program of patient and TAH model. 3-dimensional rendered set of volumes along time were used to simulate TAH fitting trial. The quantitative measurement from this simulation could be applied to customize TAH design.

  • PDF

3-Dimensional Calibration and Performance Evaluation Method for Pupil-labs Mobile Pupil Tracking Device (퓨필랩 모바일 동공 추적 장치를 위한 3차원 캘리브레이션 및 성능 평가 방법)

  • Mun, Ji-Hun;Shin, Dong-Won;Ho, Yo-Sung
    • Smart Media Journal
    • /
    • v.7 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • Pupil tracking technologies can be used as an efficient information provider means that provides convenience to the user by connecting with a smart device. In this paper, we measure the distance of user gaze point using the pupil tracking device which produced by Pupil-labs, also shows the experimental result with analyzing accuracy and precision. Based on that the pupil gaze point location which tracked by pupil tracking device is compared with object target in terms of error. Since the mobile pupil tracking device is also one kind of camera, we have to perform the calibration before using the device. Not only generally used 2-dimensional calibration, but also 3-dimensional calibration method is explained. To get the improved accuracy of 2-dimensional calibration result, the 3-dimensional calibration set an imaginary plane and executes the calibration in various 3-dimensional spaces. To show the efficiency of 3-dimensional calibration, we analyze the experimental result. It also introduces various using methods and information that can be obtained through the device.

A Two-Dimensional Terrace-Like N-heterocyclic-Pb(II) Coordination Compound: Structure and Photoluminescence Property

  • Ma, Kui-Rong;Zhu, Yu-Lan;Zhang, Yu;Li, Rong-Qing;Cao, Li
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.894-898
    • /
    • 2011
  • The first example of lead compound from $Pb(NO_3)_2$ and $H_3L$ N-heterocyclic ligand $(H_3L\;=\;(HO_2C)_2(C_3N_2)(C_3H_7)CH_2(C_6H_4)(C_6H_3)CO_2H)$, $[Pb_4(L')_4]{\cdot}5H_2O$ 1 (L' = OOC$(C_3H_7)(C_3N_2)CH_2(C_6H_4)(C_6H_3)COO)$, has been obtained under hydrothermal condition by decarboxylation, and characterized by elemental analysis, IR, TGDTA, and single-crystal X-ray diffraction. Compound 1 possesses a rare two-dimensional upper-lower offset terrace-like layer structure. In 1, crystallographic distinct Pb(II) ion adopts five-coordination geometry, and two lattice water molecules occupy the voids between 2-D layers. Results of solid state fluorescence measurement indicate that the emission band 458 nm may be assigned to $\pi^*-n$ and $\pi^*-\pi$ electronic transitions within the aromatic systems of the ligand L', however, the emission bands centred at 555 nm, 600 nm and 719 nm may be derived from phosphorescent emission ($\lambda_{excitation}$ = 390 nm).

Turbulence Kinetic Energy Budgets of Tip Vortex Generated by a Fixed Wing (고정익 끝완류의 난류 운동에너지 분배 특성)

  • Bae, Hwang;Han, Yong Oun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1444-1452
    • /
    • 1999
  • The turbulence structure of e. tip vortex generated by e. fixed wing was investigated with the use of two-dimensional laser Doppler velocimetry. The velocity field, composed of circumferential end axial components, was measured on the vertical section to the vortex trail, located at 2C downstream from the wing tip in the incoming flow condition of $Re=2.24{\times}10^5$. A quasi 3-dimensional measurement technique by use of 2-dimensional LDV system was suggested for Reynolds stresses and the higher moments. The validity of this technique was confirmed with the uncertainty analysis. The budget of the turbulence kinetic energy was analyzed by those results in the radial direction of the vortex core. It is resulted that the production is to be very likely balanced with the dissipation in most range of the vortex core.