• Title/Summary/Keyword: 2-axis control

Search Result 727, Processing Time 0.03 seconds

Dental and skeletal characteristics and growth in Class III malocclusion between skeletal ages of 10 and 14 (10세에서 14세 사이 III급 부정교합자의 치아안면두개의 형태학적 특성에 대하여)

  • Min, Seungki;Lee, Young-Jun;Park, Young-Guk;Rothstein, Ted
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.419-435
    • /
    • 2003
  • The purpose of this study was to evaluate growth changes and skeletal characteristics of Korean children with Class III malocclusions from 10 to 14 years of skeletal age. Radiographs of 60 children with Class III malocclusion and 60 normal controls were assessed. Both groups were subdivided into 6 samples according to sex and skeletal age. Skeletal age was assessed using handwrist X-rays using the Greulich and Pyle norms. The Krogman-Walker plane (occipitale-maxillon) through Sella was used as a reference plane in this study with x-axis perpendicular to the x-axis. Sir Student t-tests were conducted to compare the control group with the Class III group according to each gender a:nd age. The characteristics of Class III malocclusion group compared to the control group included shorter anterior and posterior cranial base, shorter and retrusive maxilla, forger mandible, increased molar-incisor distance, retroclined lower incisors, labially proclined upper incisors, and anteriorly located mandibular molar, smaller upper and middle facial depth, and larger lower facial depth. Landmarks representing facial depth, size of maxilla and mandible, and their AP relationship including anterior facial height indicate that growth characteristic was determined early in life. But growth Pattern of cranial base and some of the dental landmarks showed progressive divergence between Control and Class III groups with age. The position of the posterior border of the mandible was found to be significantly forward in both females and males by the age of 14 and at the anterior border in males and females at all ages. Hyperdivergent mandibular plane, changes in anterior segment of mandible, small anterior cranial base, and decrease in cranial base flexure was also noted.

A Study on the Implementation of the 2-Dimension Magnetic Fluxgate Sensor (2차원 Magnetic Fluxgate센서의 구현에 관한 연구)

  • Park, Yong-Woo;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • We have presented a 2-dimensional fluxgate sensor with ferrite core, excitation, and pick-up coil. This fluxgate sensor system consists of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through the excitation coil of 80 turns. The second harmonic output of pick-up coil(x and y axis: 100 turns) is measured by FFT spectrum analyzer. This result is compared with output of PSD(phase sensitive detector) unit for detecting the second harmonic component. The measured maximum sensitivity is about 1580 V/T at driving frequency of 1.5 kHz and excitation current of 2 App. The nonlinearity of this system is measured about 2.3%(PSD) and about 1%(second harmonics of the pick-up). The angle error of the system is ${\pm}2$ %/FS.

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

The Design and Evaluation of BACF/DCF for Mobile OIS Gyro Sensor's Zero Point angle Following (모바일 OIS(Optical Image Stabilization) 자이로 센서의 영점 각도 추종을 위한 BACF/DCF 설계 및 평가)

  • Lee, Seung-Kwon;Kong, Jin-Heung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.16-21
    • /
    • 2012
  • The gyro sensor that made by MEMS process is generated an accumulated error(drift) and escape the zero angle following during calculation of rotate angle. This study propose BACF(Boot Angle Compensation Filter) algorithm for prevent escape zero angle and DCF algorithm for remove accumulated error. DCF algorithm is designed for acquire accurate turn of ratio by remove offset and noise components. BACF algorithm is obtained average offset that removed noise components by recursively calculate. Experimental environment, two-axis gyro sensor and mobile OIS camera mounted control board and 5Hz oscillation of ${\pm}0.5^{\circ}$ for the experiments were carried out. BACF and DCF algorithm is applied and the resulting accumulated error did not occur and exactly zero angle following results were made.

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

DESIGN AND PRELIMINARY TEST RESULTS OF MAGNETOMETERS (MAG/AIM & SIM) FOR SOUNDING ROCKET KSR-III (KSR-III 과학 관측 로켓 자력계(MAG/AIM & SIM)의 초기 시험 모델 개발)

  • KIM HYO-MIN;JANG MIN-HWAN;SON DE-RAC;LEE DONG-HUN;KIM SUN-MI;HWANG SEUNG-HYUN
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.57-64
    • /
    • 2000
  • It is realized that the extraterrestrial matter is in ionized state, plasma, so the matter of this kind behaves as not expected because of its sensitiveness to electric and magnetic fields and its ability to carry electric currents. This kind of subtle change can be observed by an instrument for the magnetic field measurement, the magnetometer usually mounted on the rocket and the satellite, and based on the ground observatory. The magnetometer is a useful instrument for the spacecraft attitude control and the Earth's magnetic field measurements for the scientific purpose. In this paper, we present the preliminary design and the test results of the two onboard magnetometers of KARl's (Korea Aerospace Research Institute) sounding rocket, KSR­III, which will be launched during the period of 2001-02. The KSR-III magnetometers consist of the fluxgate magnetometer, MAG/AIM (Attitude Information Magnetometer) for acquiring the rocket flight attitude information, and of the search-coil magnetometer, MAG/SIM (Scientific Investigation Magnetometer) for the observation of the Earth's magnetic field fluctuations. With the MAG/AIM, the 3-axis attitude information can be acquired by the comparison of the resulting dc magnetic vector fields with the IGRF (International Geomagnetic Reference Field). The Earth's magnetic field fluctuations ranging from 10 to 1,000 Hz can also be observed with the MAG/SIM measurement.

  • PDF

Stereological and Morphometric Analysis of MRI Chiari Malformation Type-1

  • Alkoc, Ozan Alper;Songur, Ahmet;Eser, Olcay;Toktas, Muhsin;Gonul, Yucel;Esi, Ertap;Haktanir, Alpay
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.5
    • /
    • pp.454-461
    • /
    • 2015
  • Objective : In this study, we aimed to investigate the underlying ethiological factors in chiari malformation (CM) type-I (CMI) via performing volumetric and morphometric length-angle measurements. Methods : A total of 66 individuals [33 patients (20-65 years) with CMI and 33 control subjects] were included in this study. In sagittal MR images, tonsillar herniation length and concurrent anomalies were evaluated. Supratentorial, infratentorial, and total intracranial volumes were measured using Cavalieri method. Various cranial distances and angles were used to evaluate the platybasia and posterior cranial fossa (PCF) development. Results : Tonsillar herniation length was measured $9.09{\pm}3.39mm$ below foramen magnum in CM group. Tonsillar herniation/concurrent syringomyelia, concavity/defect of clivus, herniation of bulbus and fourth ventricle, basilar invagination and craniovertebral junction abnormality rates were 30.3, 27, 18, 2, 3, and 3 percent, respectively. Absence of cisterna magna was encountered in 87.9% of the patients. Total, IT and ST volumes and distance between Chamberlain line and tip of dens axis, Klaus index, clivus length, distance between internal occipital protuberance and opisthion were significantly decreased in patient group. Also in patient group, it was found that Welcher basal angle/Boogard angle increased and tentorial slope angle decreased. Conclusion : Mean cranial volume and length-angle measurement values significantly decreased and there was a congenital abnormality association in nearly 81.5 percent of the CM cases. As a result, it was concluded that CM ethiology can be attributed to multifactorial causes. Moreover, congenital defects can also give rise to this condition.

Investigation of Micro-vibration Isolation Performance of SMA Mesh Washer Isolator for Vibration Isolation of X-band Antenna (SMA 메쉬 와셔 진동 절연기를 적용한 X-band 안테나의 미소진동 절연성능 검토)

  • Jeon, Su-Hyeon;Kwon, Sung-Choel;Kim, Dae-Kwan;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.988-995
    • /
    • 2014
  • Two axis gimbal type X-band antenna system has been widely used to effectively transmit the real time image data from the observation satellite to the ground station. The micro-vibration generated by stepping motor actuation and imperfect intermeshed gear configuration of the antenna is one of the sources to degrade the image quality. To guarantee a high quality image of high resolution observation satellite, micro-vibration isolation of X-band antenna is required. In this paper, the X-band antenna vibration isolation system using pseudoelastic SMA(Shape Memory Alloy) mesh washer has been newly suggested. The basic characteristics of the SMA mesh washer isolator proposed in this study has been measured through static load tests and its effectiveness has been demonstrated by the micro-vibration isolation test of the X-band antenna.

Effects of Magnetic Field Intensities for Various Lengths of Time on Orientation of Fowl Spermatozoa

  • Pham, Du Ngoc;Shinjo, Akihisa;Sunagawa, Katsunori
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1367-1373
    • /
    • 2001
  • This study used fowl sperm from three White Leghom rooster reared at our laboratory. Semen samples were exposed to the magnetic field strengths of from 650 to 5700 Gauss for one. two, or three days to investigate the influence of magnetic field on the orientation of fowl spermatozoa. Fowl spermatozoa were found to orient with their long axis of heads perpendicular to the magnetic field direction. The fowl spermatozoa were initially influenced when magnetic field intensities were from 650 to 5700 Gauss and the highest values (70.67, 72.49 and 71.79%) were found in the 5700 Gauss treatment at one, two, and three days exposure, respectively. Although percentages of the perpendicular oriented fowl spermatozoa increased along with the enhancement of the magnetic field intensity, the degree of orientation was only significantly higher in the treatments having the magnetic field strength from 1500 to 5700 Gauss than that in the control treatment at all exposure time. In addition, the experimental results also showed that the percentages of all orientational types of fowl spermatozoa (perpendicular category including upward perpendicular and downward perpendicular and parallel type consisting of leftward parallel and rightward parallel) in all treatments tended to be stable during exposure time. From the results of this study. it is suggested that (1) the diamagnetic anisotropy of the inside structural components of fowl spermatozoa induce them to orient perpendicular to the magnetic field direction, (2) the degree of orientation increased according to the enhancement of magnetic field strengths, (3) fowl spermatozoa had not an high sensitivity to the magnetic field, and the level of perpendicular orientation of fowl spermatozoa in this study is nearly similar to that of cattle sperm in the study of Suga et al. (2000).

Effects of Growth Temperature and Time on Properties of ZnO Nanostructures Grown by Electrodeposition Method (Electrodeposition에 의해 성장온도와 시간을 달리하여 성장한 ZnO 나노구조의 특성)

  • Park, Youngbin;Nam, Giwoong;Park, Seonhee;Moon, Jiyun;Kim, Dongwan;Kang, Hae Ri;Kim, Haeun;Lee, Wookbin;Leem, Jae-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.4
    • /
    • pp.204-209
    • /
    • 2014
  • The electrodeposition of ZnO nanorods was performed on ITO glass. The optimization of two process parameters (solution temperature and growth time) has been studied in order to control the orientation, morphology, density, and growth rate of ZnO nanorods. The structural and optical properties of ZnO nanorods were systematically investigated by using field-emission scanning electron microscopy, X-ray diffractometer, and photoluminescence. Commonly, the results of the structural property show that hexagonal ZnO nanorods with wurtzite crystal structures have a c-axis orientation, and higher intensity for the ZnO (002) diffraction peaks. Furthermore, the nanorods length increased with increasing both the solution temperature and the growth time. The results of the optical property show a strong UV (3.28 eV) peaks and a weak visible (1.9~2.4 eV) bands, the intensity of UV peaks was increased with increasing both the solution temperature and the growth time. Especially, the UV peak for growth of nanorods at $75^{\circ}C$ blue-shift than different temperatures.