• Title/Summary/Keyword: 2-D Motion

Search Result 1,443, Processing Time 0.027 seconds

An Analysis on the Sinking Resistance of Purse Seine - 2. In the Case of the Model Purse Seine with Different Netting Material and Sinkers - (旋網의 沈降 抵抗 解析 - 2. 網地材料와 沈子量 다른 模型網의 경우 -)

  • Kim, Suk-Jong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • This study deals with an analysis on the sinking resistance for the model purse seine, in the case of different netting material and sinkers. The experiment was carried out using rune simplified model seines of knotless nettings. Dimension of model seines 420cm for corkline and 85cm for seine depth, three groups of models rigged 25, 45 and 60g with the same weighted sinkers in water were used. These were named PP-25, PA-25, PES-25, PP-45, PA-45, PES-45, PP-60, PA-60 and PES-60 seine. The densitie($\rho$) of netting materials were 0.91g/cm$cm^3$, 1.14g/cm$cm^3$ and 1.38g/cm$m^3$. Experiments carried out in the observation channel in a flume tank under still water conditions. Sinking motion was recorded by the one set of TV-camera for VTR, and reading coordinate carried out by the video digitization system. Differential equations were derived from the conservation of momenta of the model purse seines and used to determine the sinking speeds of the depths of leadline and the other portions of the seines. An analysis carried out by simultaneous differential equations for numerical method by sub-routine Runge-Kutta-Gill The results obtained were as follows : 1. Average sinking speed of leadline for the model seines rigged 60g with the same weighted sinkers in water was fastest for 12.2cm/sec of PES seine, followed by 11.4cm/sec of PA and 10.7cm/sec of PP seines. 2. The coefficient of resistance for netting of seine was estimated to be $K_D=0.09(\frac{\rho}{\rho_w})^4$ 3. The coefficient of resistance for netting bundle of seine was estimated to be $C_R=0.91(\frac{\rho}{\rho_w})$ 4. In all seines, the calculated depths of leadline closely agreed with the measured ones, each 25g, 45g, 60g of weighted sinkers were put into formulas meas.=1.04cal., meas.=0.99cal. and meas.=0.98 cal.

The Effects of Object Size and Reaching Distance on Upper Extremity Movement (물체 크기와 뻗기 거리가 상지 움직임에 미치는 영향)

  • Bae, Su-Young;Kim, Tae-Hoon
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.1
    • /
    • pp.51-61
    • /
    • 2020
  • Objectives : The purpose of this study is to investigate the effect of object size and reaching distance on kinematic factors of the upper limb while performing arm reaching for normal subjects. Methods : The subjects of this study were 30 university students who were in D university in Busan, and the measuring tool was CMS-70P(Zebris Medizintechnik Gmbh, Germany), a three-dimensional motion analyzer. The task had six conditions. The average velocity of motion, average acceleration, maximum velocity, and the velocity definite number of movements were measured according to changes in object size(2cm, 10cm) and reaching distance(15%, 37.5%, 60%) when they performed arm reaching. The general characteristics of the subject were technical statistics. One-way ANOVA measurement was used to compare variables when the arm reaching task was performed from two object sizes to three reaching distance, and the post-test was conducted with Tukey test. In addition, an independent t-test was used to analyze the kinematic differences according to the two object sizes at three reaching distances. A two-way ANOVA measurement (3×2 Two-way ANOVA measurement) was performed to identify the interaction of the reaching distance(15%, 37.5%, 60%) and the object size(2cm, 10cm). The statistical significance level α was set to .05. Results : When the size of the object increased, the velocity and maximum velocity also increased, but the definite number of velocity decreased. When the reaching distance increased, the velocity and maximum velocity increased, whereas the definite number of velocity decreased. Conclusion : The clinical significance of this study could be utilized as the baseline data for grading object size and reaching distances when the reaching training is implemented for patients whose central nervous system was damaged.

Comparison of capsule type resin modified glass ionomer porosity according to mixing methods (혼합방법에 따른 캡슐형 광중합글라스아이노머의 공극률 비교)

  • Kim, Jung-min;Kim, Jin-Woo;Cho, Kyung-Mo;Lee, Yoon;Kim, Eung-Hyun;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.217-224
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the porosity of resin modified glass ionomer (RMGI) by different mixing methods. Materials and Methods: Five specimens were prepared for each groups according to capsules and mixing methods. Two RMGI capsule and two mixing machines were used for this study. One resin-modified glass ionomer cement is Fuji II LC (F2LC) and the other is Photac Fil Quick Aplicap (PFQ). For Mixing of RMGI capsule, Rotomix using rotating motion and CM-II using shaking motion were used. After measuring height, radius and mass of specimens, Density was calculated. And porosity was measured using micro-computed tomography (micro-CT). All data were statistically analyzed using T-test, two-way ANOVA to compare between groups at 95% significance level to evaluate the affect of capsule and mixing method on the porosity. Results: The porosity was observed in all specimens generally. And there is significant differece between porosities according to RMGI capsule and Mixing method. The porosity of PFQ was lower than that of F2LC and the porosity of Rotomix was lower than that of CM-II. Conclusion: There was a difference of porosity according to kind of capsules and mixing methods. When using same capsule, less porosity was observed on PFQ than F2LC. When using same mixing mehod, less porosity was observed on Rotomix than CM-II. Using mixing machine of same coporation as that of RMGI capsule did not lead to lower porosity. Therefore, Selecting optimal mixing machine is important.

The 3-D Motion Analysis of Kinematic Variety on Lower Extremities During Ramp Descent at Different Inclinations (정상인의 내림 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석)

  • Han, Jin-Tae;Kim, Sik-Hyun;Bae, Sung-Soo
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.16-25
    • /
    • 2006
  • The aim of this study was to investigate the kinematics of young adults during descent ramp climbing at different inclinations. Twenty-three subjects descended four steps at four different inclinations (level, $-8^{\circ}$, $-16^{\circ}$, $-24^{\circ}$). The 3-D kinematics were measured by a camera-based Falcon System. The data were analyzed using one-way ANOVA and the Student-Newman-Keuls test. The kinematics of descent ramp walking could be clearly distinguished from the kinematics of level walking. On a sagittal plane, the ankle joint was more plantar flexed at initial contact with $-16^{\circ}/-24^{\circ}$ inclination, was decreased in the toe off position with all inclinations (p<.001),and was decreased at maximum plantar flexion during the swing phase (p<.001). The knee joint was more flexed at initial contact with the $-24^{\circ}$ inclination (p<.001), was more flexed in the toe off position with all inclinations (p<.001), and was more flexed at minimum flexion during stance phase and at maximum flexion during swing phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.001). The hip joint was more flexed in the toe off position with $-16^{\circ}$, $-24^{\circ}$ inclination and was deceased at maximum extension during stance phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.05). In the frontal plane, the ankle joint was more everted at maximum eversion during stance phase with $-16^{\circ}/-24^{\circ}$ inclination (p<.01) and was decreased at maximum inversion during swing phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.01). The knee joint was more increased at maximum varus during stance phase with $-16^{\circ}/-24^{\circ}$ inclination (p<.001). The hip joint was deceased at maximum adduction during stance phase with $-24^{\circ}$ inclination (p<.05). In a horizontal plane, only the knee joint was increased at maximum internal rotation during stance phase with $-24^{\circ}$ inclination (p<.05). In descent ramp walking, the different gait patterns occurred at an inclination of over $16^{\circ}$ on the descending ramp in the sagittal and frontal planes. These results suggest that there is a certain inclination angle or angular range where subjects do switch between level walking and descent ramp walking gait patterns.

  • PDF

Microzonation on Site-specific Seismic Response at a Model Area in Seoul Using GIS (GIS를 이용한 서울 시범 지역에서의 부지고유 지진 응답의 정밀구역화)

  • Sun, Chang-Guk;Chun, Sung-Ho;Jang, Eui-Ryong;Chung, Choong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.139-150
    • /
    • 2007
  • As computer technology has been rapidly advanced, geographic information system (GIS) is recently used in many disciplines. In this study, for a model area in Seoul, seismic hazard potential relating to site effects, which are influenced by the subsurface geotechnical conditions, was estimated using the GIS tool. The distribution of pre-existing borehole drilling data in Seoul metropolitan area was examined for the regional estimation of site-specific seismic responses at the model area. Spatial geo-layers across the entire model area were predicted by constructing a GIS-based geotechnical information system (GTIS). A microzonation of site period $(T_G)$ for estimating site-specific seismic responses at the model area was performed within the GTIS. The spatial microzoning map of $T_G$ indicated seismic vulnerability of two- to four-storied buildings in the model area. Furthermore, a site classification map for determining the design ground motion was established based on the $T_G$ within the GTIS. This informed that most of location in the model area was categorized into current site classes C and D. This seismic microzonation framework for the model area could be applicable particularly in the entire Seoul metropolitan area based on the pre-existing borehole data.

Effects of Korean Medicinal Treatments Including Antaeeum-gamibang on Posterior Neck Pain and Lower Back Pain Caused by Traffic Accidents During Pregnancy: Five Case Reports (안태음(安胎飮) 가미방(加味方)과 한방치료를 병행한 임신 중 교통사고로 인한 경추 및 요추부 통증 환자 치험 5례)

  • Shin, Soo-Ji;Kim, Gil-Hwan;Ju, Yeong-Guk;Lee, So-Jin;Ahn, Sang-Min;Jeong, Jae-Joong
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.3
    • /
    • pp.146-157
    • /
    • 2017
  • Objectives: This study was performed to assess the effectiveness of Korean medicinal treatments including Antaeeum-gamibang on posterior neck pain and lower back pain caused by traffic accidents during pregnancy. Methods: Patients were treated by Antaeeum-gamibang, acupuncture and Chuna manual therapy. To measure treatment outcomes, Numerical rating scale (NRS), Oswestry disability index (ODI), Neck disability index (NDI), European Quality of Life-5 Dimensions (EQ-5d), and range of motion (ROM) were used. Results: After treatment, the average NRS of posterior neck pain significantly decreased from $4.20{\pm}1.30$ to $1.80{\pm}0.45$ and the average NRS of lower back pain significantly decreased from $6.40{\pm}1.14$ to $2.20{\pm}0.84$. ODI significantly decreased from $41.42{\pm}17.79$ to $28.29{\pm}14.69$, NDI significantly decreased from $34.93{\pm}9.85$ to $20.27{\pm}8.96$. EQ-5d and ROM improved at all cases. Conclusions: Korean Medicinal treatments including Antaeeum-gamibang may be effective in the treatment of posterior neck pain and lower back pain caused by traffic accidents during pregnancy. However, more case reports and studies are required to identify exactly what treatment is more efficient.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Comparative Analysis of Structural Damage Potentials Observed in the 9.12 Gyeongju and 11.15 Pohang Earthquakes (9.12 경주지진 및 11.15 포항지진의 구조손상 포텐셜 비교연구)

  • Lee, Cheol-Ho;Kim, Sung-Yong;Park, Ji-Hun;Kim, Dong-Kwan;Kim, Tae-Jin;Park, Kyoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.175-184
    • /
    • 2018
  • In this paper, comparative analysis of the 9.12 Gyeongju and 11.15 Pohang earthquakes was conducted in order to provide probable explanations and reasons for the damage observed in the 11.15 Pohang earthquake from both earthquake and structural engineering perspectives. The damage potentials like Arias intensity, effective peak ground acceleration, etc observed in the 11.15 Pohang earthquake were generally weaker than those of the 9.12 Gyeongju earthquake. However, in contrast to the high-frequency dominant nature of the 9.12 Gyeongju earthquake records, the spectral power of PHA2 record observed in the soft soil site was highly concentrated around 2Hz. The base shear around 2 Hz frequency was as high as 40% building weight. This frequency band is very close to the fundamental frequency of the piloti-type buildings severely damaged in the northern part of Pohang. Unfortunately, in addition to inherent vertical irregularity, most of the damaged piloti-type buildings had plan irregularity as well and were non-seismic. All these contributed to the fatal damage. Inelastic dynamic analysis indicated that PHA2 record demands system ductility capacity of 3.5 for a structure with a fundamental period of 0.5 sec and yield base shear strength of 10% building weight. The system ductility level of 3.5 seems very difficult to be achievable in non-seismic brittle piloti-type buildings. The soil profile of the PHA2 site was inversely estimated based on deconvolution technique and trial-error procedure with utilizing available records measured at several rock sites during the 11.15 Pohang earthquake. The soil profile estimated was very typical of soil class D, implying significant soil amplification in the 11.15 Pohang earthquake. The 11.15 Pohang earthquake gave us the expensive lesson that near-collapse damage to irregular and brittle buildings is highly possible when soil is soft and epicenter is close, although the earthquake magnitude is just minor to moderate (M 5+).

Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis (Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과)

  • Kim, Y.H.;Park, E.Y.;Kim, W.H.;Hwang, S.P.;Park, K.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF