• 제목/요약/키워드: 2 dimensional image

검색결과 1,529건 처리시간 0.031초

MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구 (Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System)

  • 최해만;문자수명;송정강일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

비디오 시스템과 영상매칭에 의한 운동물체의 거동측정 (Measurements of the Trajectories of Moving Objects with Video System and Image Matching)

  • 이창경;조우석
    • 한국측량학회지
    • /
    • 제20권3호
    • /
    • pp.331-341
    • /
    • 2002
  • 평면 이미지로부터 3차원 정보를 구하기 위해서는 스테레오 이미지가 필요하고, 움직이는 물체의 거동을 3차원적으로 측정하기 위해서는 스테레오 이미지의 정확한 동기가 필수적이다. 또한, 연속적인 거동측정을 위해서는 동시 촬영한 연속 스테레오 이미지가 필요하고, 위치추적의 자동화를 위해서는 영상 매칭이 그 해결책이다. 본 연구에서는 한 대의 비디오 카메라로 움직이는 물체의 연속 스테레오 이미지를 촬영하여, 영상 매칭에 의해 동일 대상물 및 동일 측점의 중심위치를 결정하고, DLT에 의해 3차원 위치를 해석하는 방법을 제시하였다.

이미지 기울기에서 선별된 포아송 모델을 이용한 이미지 재구성 (Image Reconstruction Using Poisson Model Screened from Image Gradient)

  • 김용길
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.117-123
    • /
    • 2018
  • 본 연구에서는 이미지 기울기 영역에서 포아송 방정식을 이용한 빠른 이미지 재구성 기법을 제안한다. 포아송 방정식을 사용하는 이 접근법에서, 유도된 벡터 필드는 제 1 단계에서 선택된 영역 내에서 원본과 대상 이미지를 사용함으로써 생성된다. 다음으로, 유도된 벡터는 결과 이미지를 생성하는데 사용된다. 우리는 원하는 기울기 집합과 데이터 항을 근사화하는 2차원 함수를 재구성하는 문제를 분석했다. 결합된 데이터와 기울기는 원본 이미지에 가깝게 머무르는 동안 이미지 기울기를 수정하는 것처럼 작동 할 수 있다. 이 공식으로부터 우리는 물리학에서 알려진 포아송 방정식을 찾아냈다. 이 방정식은 FFT 도메인의 문제에 대한 효율적인 해결책을 제시한다. 이것은 2차원으로 알려진 포아송 모델을 해결하고 기울기 비례축소는 라플라스를 확실하게 일반화하는 잘 정의된 선명한 필터임을 공간 필터에 잘 나타냅니다. 포아송 모델을 기반으로 이산 코사인 변환을 사용하여 결과를 확인할 수 있었다.

모양 정보의 회귀추정에 의한 내용 기반 이미지 검색 기법 (Contents-based Image Retrieval Using Regression of Shape Features)

  • 송준규;최황규
    • 디지털콘텐츠학회 논문지
    • /
    • 제2권2호
    • /
    • pp.157-166
    • /
    • 2001
  • 본 논문은 내용 기반 이미지 검색 시스템에서 이미지의 위치 및 모양 정보에 의한 회귀선을 추정하여 효율적으로 특징 벡터 추출함과 동시에 같은 도메인상의 특징 벡터가 일정 수준보다 많아질 경우 효율적으로 특징 벡터의 차원을 줄이는 기법을 제안한다. 특히, 특징 벡터의 차원을 줄이는 제안된 기법은 특징 벡터의 수에 관계없이 특정한 n개의 특징 벡터로의 변환이 가능하다. 본 논문에서 제안된 기법들은 실제 내용 기반 이미지 검색 시스템의 구현을 통해 기존의 방법보다 효율적인 검색은 물론 다차원 특징 벡터를 특정 n차원의 특징 벡터로 변환함으로써 다차원 색인 기법이 가지고 있는 가장 큰 단점인 '차원의 저주' 문제를 근본적으로 해결할 수 있는 방법임을 보인다.

  • PDF

Mapping of Real-Time 3D object movement

  • Tengis, Tserendondog;Batmunkh, Amar
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.1-8
    • /
    • 2015
  • Tracking of an object in 3D space performed in real-time is a significant task in different domains from autonomous robots to smart vehicles. In traditional methods, specific data acquisition equipments such as radars, lasers etc, are used. Contemporary computer technology development accelerates image processing, and it results in three-dimensional stereo vision to be used for localizing and object tracking in space. This paper describes a system for tracking three dimensional motion of an object using color information in real time. We create stereo images using pair of a simple web camera, raw data of an object positions are collected under realistic noisy conditions. The system has been tested using OpenCV and Matlab and the results of the experiments are presented here.

디지털 홀로그램 방송을 위한 영상 콘텐츠의 암호화 (Image Contents Encryption Technique for Digital Hologram Broadcasting Service)

  • 하준;최현준
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.818-819
    • /
    • 2013
  • 본 논문에서는 디지털 홀로그래픽 방송 서비스를 위한 콘텐츠 암호화 기술을 제안한다. 디지털 홀로그래픽 비디오 서비스는 현존하는 2차원 또는 3차원 비디오를 서비스하는 시스템의 프레임, 즉 데이터의 획득, 처리, 전송, 수신, 복원의 과정을 그대로 따른다고 가정한다. 본 논문에서는 이와 같은 시스템을 위해 RGB 영상과 깊이정보의 암호화를 수행한다. 실험결과 전체 데이터 중에서 0.048%의 데이터만을 암호화하여 원본 RGB 영상과 깊이정보의 시각적인 정보를 은닉할 수 있었다.

  • PDF

소음원 영상화를 위한 마이크로폰 배열 설계 (Microphone Array Design for Noise Source Imaging)

  • 윤종락
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.255-260
    • /
    • 1997
  • This paper describes 3-dimensional volume array of 4 microphones including a reference microphone which is capable of imaging wideband noise source position in 2-dimensional image plane. The cross correlation function and corresponding imaging function between a reference microphone and other microphone, are derived as a function of noise source position. The magnitude of the imaging function gives noise source mapping in image plane. Since the image plane is selective from a rectangular and a cylindrical plane, noise source position information such as range and bearing relative to the array is identified very much easily. Simulation results for typical source configurations confirms the applicability of the proposed array in noise control field.

  • PDF

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

집적 영상 기술을 이용한 3차원 지도 시스템 (Three-Dimensional Map System Using Integral Imaging Technique)

  • 조명진
    • 한국정보통신학회논문지
    • /
    • 제18권11호
    • /
    • pp.2799-2804
    • /
    • 2014
  • 본 논문에서는 집적 영상 기술을 사용하여 3차원 정보를 추출하는 지도 시스템을 제안한다. 집적 영상 기술은 렌즈 배열을 가지는 2차원 영상 획득장치를 사용하여 다수의 서로 다른 원근감을 가지는 요소 영상을 기록하고 이를 이용하여 3차원 정보를 획득하고 디스플레이하는 기술이다. 본 논문에서는 각 요소 영상간의 위치 차이를 절대 차이의 합 (Summation of Absolute Difference: SAD)를 사용하여 구하고 이를 이용하여 3차원 정보를 추출한다. 따라서, 3차원 물체의 높이 정보를 구할 수 있다.

삼차원 전산화단층촬영사진과 측모두부 방사선규격사진의 계측자에 따른 계측오차에 대한 비교분석 (Comparison of the observer reliability of cranial anatomic landmarks based on cephalometric radiograph and three-dimensional computed tomography scans)

  • 김재영;이동근;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.262-269
    • /
    • 2010
  • Introduction: Accurate diagnosis and treatment planning are very important for orthognathic surgery. A small error in diagnosis can cause postoperative functional and esthetic problems. Pre-existing 2-dimensional (D) chephalogram analysis has a high likelihood of error due to its intrinsic and extrinsic problems. A cephalogram can also be inaccurate due to the limited anatomic points, superimposition of the image, and the considerable time and effort required. Recently, an improvement in technology and popularization of computed tomography (CT) provides patients with 3-D computer based cephalometric analysis, which complements traditional analysis in many ways. However, the results are affected by the experience and the subject of the investigator. Materials and Methods: The effects of the sources human error in 2-D cephalogram analysis and 3-D computerized tomography cephalometric analysis were compared using Simplant CMF program. From 2008 Jan to 2009 June, patients who had undergone CT, cephalo AP, lat were investigated. Results: 1. In the 3 D and 2 D images, 10 out of 93 variables (10.4%) and 11 out 44 variables (25%), respectively, showed a significant difference. 2. Landmarks that showed a significant difference in the 2 D image were the points frequently superimposed anatomically. 3. Go Po Orb landmarks, which showed a significant difference in the 3 D images, were found to be the artificial points for analysis in the 2 D image, and in the current definition, these points cannot be used for reproducibility in the 3 D image. Conclusion: Generally, 3-D CT images provide more precise identification of the traditional cephalometric landmark. Greater variability of certain landmarks in the mediolateral direction is probably related to the inadequate definition of the landmarks in the third dimension.