• Title/Summary/Keyword: 2차 유량

Search Result 382, Processing Time 0.026 seconds

Analytical Study of the Subsonic/Sonic Ejector Flows (아음속/음속 이젝터의 유동에 관한 해석적 연구)

  • 최보규;김희동;김덕줄
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • In order to predict the performance of subsonic/sonic ejector system and to provide fundamental data for a cost effective design, one dimensional gas dynamics theory was applied to the subsonic and sonic ejector systems with the second throat. In the current theoretical analyses, ejector throat area ratio, mass flow ratio and secondary stagnation pressure were derived as a function of the operating pressure ratio of the ejector, and the discharge coefficient of the primary nozzle and the loss coefficient of the diffuser were incorporated into the whole performance of the ejector system. The results of theoretical analysis can be applied to practical industrial use of subsonic and sonic gas ejector systems.

  • PDF

Long-term prediction of streamflow for water resource management in Geumho River watershed (중장기 하천유량 관리를 위한 금호강 유역의 유출량 예측)

  • Kim, Han Na;Park, Jung Eun;Kang, Shin Uk;Lee, Eul Rae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.416-416
    • /
    • 2015
  • 기후변화는 미래 강수량 변동을 야기하여 하천유량 관리에 큰 영향을 미칠 것으로 예상하고 있다. 이에 본 연구에서는 기후변화에 따른 중장기 하천유량 관리를 위하여 금호강 유역을 대상으로 SWAT 모형을 이용하여 중장기 하천유량을 예측하였다. 임하댐 상류지역의 2008~2012년 유량자료에 대하여 보정 완료된 SWAT 모형을 기반으로, 지역기후모형(RCM)인 HadGEM3-RA모형을 활용한 IPCC 제5차 보고서 RCP 4.5, RCP 8.5 시나리오를 적용하였다. 금호강 표준유역별 기후변화에 의한 영향을 모의하기 위하여 편이보정(Bias Correction)방법을 적용하였으며, 금호강 유역 내 과거 30년(1975~2005년, Baseline) 기상자료와 비교하여 통계적인 유사성을 가지도록 보정을 실시하였다. 기후변화 시나리오 적용결과는 S1(2011~2040년), S2(2041~2070년), S3(2071~2099년)으로 분할하여 월별, 계절별, 연도별 미래 강수량과 기온을 분석하였다. 분석 결과, RCP 4.5 시나리오의 경우 봄철(3~5월)의 강수량은 기준년도에 비해 약 57%가 증가하였으나, 가을철(6~8월)에는 7.9% 감소하였으며, 첨두 강수시기는 8~9월에서 6~7월로 이동하였다. 평균기온은 각 구분 시기별 $0.2^{\circ}C$, $1.1^{\circ}C$, $1.8^{\circ}C$ 정도 상승할 것으로 예측되었다. RCP 8.5 시나리오에서는 기준년도 대비 강우량은 봄철에 61% 증가, 가을철에는 14.9% 감소하는 것으로 모의되었다. 평균기온은 약 $0.4^{\circ}C$, $2.1^{\circ}C$, $4.2^{\circ}C$ 정도 상승하는 것으로 나타났다. 기후변화에 따른 유출량 결과 비교는 2001~2010년을 기준으로 하였으며, RCP 4.5 시나리오에서는 S1, S2, S3 시기별 각각 -10.9%, -7%, -3.6% 감소하였으며, RCP 8.5 시나리오에서는 약 -12.3%, 4.9%, -1.2% 변동하는 것으로 나타냈다. 금호강 유역 전반에 걸쳐 유출량이 감소하는 추세를 보였으며, 특히 본류에 비해 지류유역의 건천화가 심해지는 양상을 보였다. 또한 현재에 비해 여름철 유출패턴 시기가 앞당겨져 봄철 유량이 증가하고 겨울철에 감소하는 경향을 보이고 있다. 기후변화로 인한 수문패턴의 변화로 현재 하천유량관리의 변화가 필요할 것으로 판단되며, 향후 본 연구결과를 바탕으로 물수지 분석을 추가하여 유지유량 만족을 위한 해당유역의 이수기 유량관리 방안 연구를 수행할 예정이다.

  • PDF

Characteristics of LPG fuel Reforming in Plasma Reformer for Hydrogen Production (수소 생성을 위한 플라즈마 개질기에서의 LPG 연료의 개질 특성)

  • Park, Yunhwan;Lee, Deahoon;Kim, Changup;Kang, Kernyong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • In this study, characteristics of the geometric design changes of plasma reformer for LPG fuelled vehicles were studied. To improve the yield of hydrogen, reformer 1st, and 2nd were designed. Secondary reformer compared to the primary reformer to increase the volume of the rear part of reformed gas having passed through the plasma and increased reaction time. To compare reforming results of two reformers, various experimental conditions such as, from partial oxidation to total oxidation conditions $O_2/C$ ratios, and total flow rate of 20, 30, 40, 50 lpm conditions, were varied. Results showed that with increasing $O_2/C$ ratios, LPG conversion rate increased, decreased hydrogen selectivity and hydrogen yield optimal point existed and secondary reformer 4.5 times larger than the primary reformer at the same flow rate to 4~14% increase in the yield of hydrogen.

Study on Air Entrainment Occurred to Intake Facility of Circular Multi Stage Cylinder Gate (원형 다단 실린더 게이트 형식의 취수시설에서 발생하는 공기연행에 대한 연구)

  • Jang, Yong;Oh, Jun Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.150-150
    • /
    • 2020
  • 본 연구에서는 수리모형실험을 통하여 원형 다단 실린더 게이트 형식의 취수시설에서 발생하는 공기연행을 분석하였다. 수리모형실험의 원형은 경상북도 청도군에 위치한 운문댐의 "운문댐 안전성 강화사업"에서 계획되고 있는 신설취수탑을 기준으로 상사법칙은 Froude상사법칙을 적용하고 1/20의 모형 축척을 가지는 취수탑의 국부모형에 하류단 수위를 고려하기 위해 유량조절시설을 설치하여 실험을 실시하였다. 실험조건은 크게 두 가지로 구분하였으며, 수면으로부터 유입구 상단부까지의 거리 ∆h1(m)과 유입부 저수지 저류 수위와 하류단 유량조절시설간의 수위차인 ∆h2(m)이며, ∆h1에 대한 조건은 0.01m~0.06m로 0.01m 간격으로 6가지, ∆h2에 대한 조건은 0.10m~1.70m로 0.20m간격으로 9가지로 이를 조합하여 총 54개 CASE에 대해 진행하였다. 실험결과 공기연행 발생 시 그에 따른 영향을 평가하기 위해 발생 정도에 따라 미발생(Not Occur), 간헐적(Intermittent), 빈번한(Frequent), 지속적(Continuation), 공기 폭발(Air Explosion)로 분류하였으며, 각 공기연행 발생 시 취수유량의 감소율 및 영향을 분석한 결과 간헐적 공기연행 발생 시 최대 약 3.75%의 취수유량 감소, 빈번한 공기연행 발생 시 취수유량은 전체적으로 10%, 최대 약 13.19% 감소하였으며, 지속적 공기연행 발생 시 발생 이후 ∆h2증가에 의한 취수유량의 증가가 거의 이루어지지 않으며, 최대 56.25%의 취수유량이 감소, 공기 폭발 발생 시 취수유량의 영향은 지속적 발생과 비슷하나 관내 공기 포집 후 유입구로 방출 시 관에 강한 충격을 주어 안정성에도 큰 영향을 미칠 것으로 판단되어, 이에 안정성 및 취수유량 감소율을 고려하여 빈번, 지속, 공기 폭발 발생 영역에서의 취수는 적합하지 않으며, 공기연행 미발생 및 간헐적 발생 영역에서의 취수 시 목표 취수유량이 1.00~4.00(㎥/s)일 때 ∆h1= 0.40m 이상, 4.00~9.30(㎥/s) 일 때 ∆h1= 0.60m 이상, 9.30~9.53(㎥/s) 일 때 ∆h1=0.80m 이상, 9.53~9.65(㎥/s) 일 때 ∆h1= 1.00m 이상에서 취수유량 감소율 3.75% 이내로 취수유량의 확보가 가능하다. 이러한 결과는 원형 다단 실린더 게이트 형식의 취수시설에 대해 취수 시 수면와류에 의한 Air Core와 그에 따른 공기연행의 발생 조건과 영향을 수리모형실험을 통해 확인함으로써 실제 운용 시 보다 안정적이고 효율적인 운용에 대한 자료로 활용될 수 있을 것으로 판단되며, 추가로 수치해석을 통한 비교 및 공기연행과 관내 공기포집 정도에 대한 연구를 통해 보다 정확한 자료제시가 가능할 것으로 판단된다.

  • PDF

Analysis of submerged flow characteristics of the improved-pneumatic-movable weir through the laboratory experiments (개량형 공압식 가동보의 잠김흐름 특성 분석을 위한 실험연구)

  • Lee, Kyung Su;Jang, Chang-Lae;Lee, Namjoo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.615-623
    • /
    • 2016
  • This Study calculated the Submerged Flow Characteristics and Discharge coefficient by the rising angular change of the Improved-Pneumatic-Movable. According to the result, the smaller the ratio of weir height and weir length (L/W) or the weir standing angle, the bigger of the downstream head ($H_2$). The change of discharge reduction factor ($Q_s/Q_1$), by the hight from weir crest to downstream surface and the ratio form weir crest to upstream water height ($h_t/H$), was decreased when the $h_t/H$ closed to number 1. Although the weir water depth of the down-stream was shallower level than the up-stream, the velocity was faster then before. And the more the flow, the less the gab between the upper and lower reaches level. And when the same flow condition, the downstream head ($H_2$) was increased when the L/W was bigger. The Submerged Flow Discharge coefficient of Improved-Pneumatic-Movable weir was made by the upstream approach flow head and the upper lower stream flow condition, not by the physical data of Movable weir.

Flow Rate Control Characteristics of a Cavitating Venturi in a Liquid Rocket Propellant Feed System (액체로켓 추진제 공급계에서 캐비테이션 벤튜리의 유량 제어 특성)

  • Cho, Won-Kook;Moon, Yoon-Wan;Kwon, Oh-Sung;Cho, In-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.46-52
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Both experiment and numerical simulation have been performed to give about 10% discrepancy of mass flow rate for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3{\times}10^5$pa when the upstream pressure is fixed to $22.8{\times}10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristics is relatively insensitive to the mass fraction of non-condensable gas. So it reduces by only 2% when the non-condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansion of the non-condensable gas and the evaporation of liquid are verified to gave same effect to the pressure recovery pattern.

Efficiency of Geothermal Energy Generation Assessed from Measurements of Deep Depth Geothermal Conductivity (고심도 지중열전도도에 의한 지열 응용의 효율성)

  • Cho, Heuy-Nam;Lee, Dal-Heui;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.233-241
    • /
    • 2012
  • The objectives of this study were to test geothermal conductivity (k), water velocity, water quantity, and pipe pressure from a ground heat exchanger in the field, and then to analyze these data in relation to the effectiveness and economical efficiency for application of geothermal energy. After installation of the apparatus required for field tests, geothermal conductivity values were obtained from three different cases (second, third, and fourth). The k values of the second case (506 m depth) and third case (151 m depth) are approximately 2.9 and 2.8, respectively. The k value of the fourth case (506 m depth, double pipe) is 2.5, which is similar to the second and third cases. This result indicates that hole depth is a critical factor for geothermal applications. Analysis of the field data (k, water velocity, water quantity, and pipe pressure) reveals that a single geothermal system at 506 m depth is more economically efficient than three geothermal systems at depths intervals of 151 m. Although it is more expensive to install a geothermal system at 506 m depth than at 151 m depth, test results showed that the geothermal system of the fourth case (506 m, double pipe) is more economically efficient than the system at 151 m depth. Considering the optional cost of maintenance, which is a non-operational expense, the geothermal system of the fourth case is economically efficient. Large cities and areas with high land prices should make greater use of geothermal energy.

A Study on Low-flow Frequency Analysis Using Dam Inflow (댐 유입량 자료를 이용한 갈수빈도해석에 대한 연구)

  • Jung, Younghun;Nam, Woo Sung;Shin, Hongjoon;Heo, Jun-Haeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6B
    • /
    • pp.363-371
    • /
    • 2012
  • In this study, the low-flow frequency analysis was performed to determine the low-flow standard of dam maintenance flow for Hwacheon and Chuncheon dams. For this purpose, two methods (case 1: low-flow frequency analysis using the monthly inflow data of the specified return periods, case 2: low-flow frequency analysis using the difference of monthly accumulated inflow) were applied. As a result, it is found that the monthly inflow data of the return periods by reflecting the statistical characteristics of Hwacheon and Chuncheon dams can be utilized to determine the standard of maintenance flow or water level.

A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors (천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구)

  • Ha Youngcheol;Lee Chulgu;Chang Seungyong;Lee Kangjin
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.83-89
    • /
    • 1998
  • Experiments had been conducted Qualitatively regarding flow measurement errors of orifice flowmeter due to temperature difference between the inside and outside the natural gas meter-run in case of no pipe insulations. The primary factors considered in this study are fluid velocity and surrounding temperature. In addition, a portion of thermal radiation due to the sun was involved as a factor. The results showed that the considerable errors were not detected even in conditions of low flow rates and large temperature difference between the inside and outside the meter-run.

  • PDF