• Title/Summary/Keyword: 2차 방사선

Search Result 892, Processing Time 0.033 seconds

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

The Effects of RGDS Tetrapeptide on the Calcification of the Bovine Pericardium Transplanted Subcutaneously in Rats (흰쥐에서 RGDS tetrapeptide가 소 심낭 이식절편의 피하이식 후 석회화에 미치는 영향)

  • Jin, Ung;Lee, Ju-Hyeon;Kim, Chi-Kyung;Lee, Sun-Hee
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.94-101
    • /
    • 2002
  • All kinds of tissue valves must be pretreated for the inactivation of immunologic properties and the strengthening of tissue before implantation. However, the tissue valves are gradually denatured with the calcification process and they eventually lose their functions. Recent reports have shown the existence of specific calcium binding non collagenous proteins in the calcified area of implanted biomaterials. This experiment was intended to confirm the effect of pretreatment with RGDS(Arg-Gly-Asp-Ser) tetrapeptide on the calcification of subcutaneously implanted bovine pericardium in rats. RGDS tetrapeptide has the same amino acid sequence of attachment site of specific calcium binding non collagenous proteins. Material and Method: All bovine pericardial pieces were fixed with 0.6% glutaraldehyde. The pretreatments were done using 5 different methods, groupI, with normal saline for 60 minutes, groupII, with 0.5% GRSD(Gly-Arg-Scr-Asp) tetrapeptide solution for 60 minutes, group III : with 0.5% RGDS(Arg-Gly-Asp-Ser) tctrapeptide for 30 minutes, group IV ; with 0.5% RGDS for 60 minutes, and group V : with 0.5% RGDS for 120 minutes. The pretreated bovine pericardial pieces were implanted subcutaneously at the abdominal sites of rats. 30 days after the implantation, the implanted bovine pericardial tissue were examined radiologically, biochemically, and histologically to measure the severity of calcification. Result: On the radiological examination, group I ; 68.42$\pm$3.06, group II , 64.25$\pm$5.58 showed significant difference with group III: 48.00$\pm$3.57, group IV; 43.67$\pm$2.31, and group V ; 2.58$\pm$2.47(p<0.05). There was no difference between group I and II(p=0.105). On the biochemical examination, the amount of calcium in group I was , 33.09$\pm$6.59 mg, in group II ; 28.12$\pm$5.50mg, in group III ; 25.42$\pm$7.67mg, in group Ⅵ ; 20.51$\pm$5.11mg, and in group V : 15.43$\pm$4.25mg.

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF

After retrospective evaluation of the SETUP rate change during the treatment of head and neck cancer patient with Helical Tomotherapy (두경부환자의 토모테라피 치료시 SETUP 변화율에 대한 후향적 평가)

  • Ha, Tae-young;Kim, Seung-jun;Hwang, Cheol-hwan;Son, Jong-gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • Purpose : Retrospective evaluation of setup changes using the corrected position during helical tomotherapy Materials and Methods : Head and neck cancer patients were randomly sampled and summarized into 3 groups: Group 1(32) Brain, Group 2 2(28)Maxillar, Nasal cavity, Group 3 (35) Nasopharynx(NPX), Tongue, Tonsil, and Oropharynx(OPX). In 3 groups, the statistical tests based on repeated measurements among 30 times of the duration of treatment by applying X, Y, Z axis errors, roll, weight changes, and vectors as variables. Results : The statistical test results showed that there was no difference between x-axis (p = 0.458) and y-axis (p=0.986) and in roll (p = 0.037), weight change (p <0.001), and the vector (p <0.001). In addition, the pattern between the three groups based on the fraction revealed no difference in x-axis (p = 0.430) and roll (p = 0.299) but a difference in y-axis (.023), weight change (p = 0.001), and vector (p = 0.028). Conclusion : The results of the retrospective evaluation found the change in the group 3 with respect Y, Z, weight, and vector and a larger random error during the treatment including low neck.

  • PDF

APEXOGENESIS OF A DENS EVAGINATUS (하악 소구치에 발생한 치외치의 치근단유도술)

  • Lee, Ji-Min;Choi, Yeong-Chul;Kim, Kwang-Chul;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.305-309
    • /
    • 2009
  • Dens evaginatus is a dental anomaly most commonly seen in premolar teeth in which a tubercle or protuberance projects from either the center of the occlusal surface or the buccal triangular ridge. These tubercles are easily fractured from mastication as the tooth erupts and frequently leads to pulp necrosis as a common complication. To prevent these sequelae, prophylactic treatment soon after the tooth starts erupting is essential. These preventive treatments include, selective grinding and protection of the tubercle by pit and fissure sealant. When the tooth does shows signs of pulp necrosis and apical periodontitis, endodontic procedures are needed. Apexification and apexogenesis are usually the treatment of choice for the affected teeth which have immature apices. Apexogenesis is a vital pulp therapy procedure performed to encourage continued physiological development and formation of the root end. It involves removal of the inflamed pulp and the placement of calcium hydroxide on the remaining healthy pulp tissue. This case report describes an atypical apexogenesis of a mandibular premolar which showed to be a dens evaginatus. The tooth which was treated with calcium hydroxide shows good results and is planned for permanent root canal filling.

  • PDF

The Analysis and Treatment of Benign Bone Tumor by Curettage and Debridement with Bone Graft Substitutes (양성 골종양의 절제 및 소파술 후 사용한 골이식 대체물의 결과 및 분석)

  • Jung, Sung-Taek;Seo, Hyoung-Yeon;Seon, Jong-Keun;Lee, Jae-Joon;Kim, Seung-Sik
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.139-147
    • /
    • 2003
  • Purpose: The purpose of this study was to determine if bony union can be obtained when a bone graft substitute is transplanted in order to treat a benign bone tumor and if there is a difference between calcium sulfate and hydroxyapatite in the healing procedure when the degree of the bony union after the bone graft are compared. Materials and Methods: This study selected 20 cases, in which a curettage on the benign bone tumors was conducted and a bone graft substitute was transplanted. The area of the focus, the new bone formation, the recurrence of the focus in the plain radiographs and histological findings were observed. Results: Twenty cases (13 males, 7 females) were evaluated. Their mean age at surgery was 15.8 years (2~45), and the mean follow-up period was 3 years. The mean area of focus was 30.7 $cm^3$ in the radiographs, and 19 cases showed successful results in the ultimate visit, while 1 case has a recurrence of the focus. Conclusion: Calcium sulfate has osteoconduction and superior bioavailability, and is absorbed in vivo in proportion to the new bone formation. On the other hand, hydroxyapatite has good osteoconduction. It can result in better bone formation when it is combined with an autologous bone graft, autologous bone marrow, and an allogenic bone graft, but is absorbed in vivo more slowly than the former.

  • PDF

THE LATERAL CEPHALOMETRIC STUDY OF THE GROWING CHILDREN WITH CLASS III MALOCCLUSION BY KIM'S ANALYSIS (Kim's analysis에 의한 III급 부정교합아동의 측모두부방사선 계측학적 연구)

  • Yang, Ku-Ho;Choi, Nam-Ki;Jeong, Jin-Gug
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.298-307
    • /
    • 2003
  • The purpose of this study was to investigate the distribution and differences of the cephalometric measurements between normal occlusion and the class III malocclusion. Kim's analysis was achieved and compared on both the 141 elementary school students with proper profile and normal occlusion and the class III malocclusion group at the age of 7 to 9, in Gwang-ju area and the results were as follows; 1. The ODI, APDI, IIA, UL showed statistically significant differences between normal occlusion and class III malocclusion(p<0.01). But, no significant difference existed in both CF and EI. 2. The mean value of ODI was 72.62, APDI 80.47 IIA 121.37 in normal occlusion. 3. The mean value of ODI was 64.45, APDI 87.31 IIA 129.89 in class III malocclusion. 4. ODI decreased as APDI increased, and the correlation coefficient was -0.576 in both normal occlusion and class III malocclusion. 5. The correlation coefficient related to EI was CF 0.777, LL -0.670, UL -0.588, IIA 0.485. It means that UL and LL were very sensitively reflected on EI.

  • PDF

Operative Treatment of Capitellar Fractures Associated with/without Other Injury Around the Elbow (단순 혹은 주관절 주위 손상을 동반한 소두 골절의 수술적 치료)

  • Kang, Ho-Jung;Park, Kwang-Hwan;Lee, Jung-Kil;Choi, Yun-Rak;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • Purpose: We wanted to assess the radiological and clinical results and the prognostic factors after an operation for capitellar fractures associated with/without other injury around the elbow. Materials and Methods: Among the 25 patients (mean age: 49 years-old) who underwent open reduction and internal fixation for capitellar fractures, there were nineteen type 1 fractures and six type 3 fractures. The mean follow up period was 14.8 months. We assessed the factors affecting the radiological and functional results, such as the fracture pattern, the patient age and the surgical approaches. Results: In 24 of 25 patients, bony union was achieved at postoperative 1 year. There were eighteen excellent, four good, two fair and one poor functional results according to the Broberg and Morrey elbow score. The most common type was type 1 and the most common associated injury was lateral condylar fracture. The patients with type 1 fracture rather than the patients with type 3 fracture and the patients who had an extraarticular associated fracture rather than an intraarticular associated fracture had better clinical outcomes. Conclusion: 22 (88%) of the patients were satisfied at the result. The type of capitellar fracture and an associated intraarticular elbow fracture were shown to be important prognostic factors in this study.

Soaking method & Particle In Binder method를 적용한 Photoconductor materials의 제작방식에 따른 X-ray Detector film 제작 및 전기적 특성평가

  • Lee, Yeong-Gyu;Yun, Min-Seok;Kim, Min-U;Kim, Yun-Seok;Jeong, Suk-Hui;Jeon, Seung-Pyo;Park, Geun-U;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.72-72
    • /
    • 2009
  • 본 연구에서는 Photoconductor materials 기반의 평판형 X-ray Detector film 제작에 관한 연구를 수행하였다. 기존의 광도전성 물질로 사용되어 오던 비정질 셀레늄(Amorphous seleinum; a-Se) 기반의 디지털 방사선 검출기 보다 높은 신호 및 동작 특성을 가지는 Mercury Iodide(HgI2)와 열적, 전기적 특성이 안정적이며, 소자의 동작특성이 우수한 Lead Oxide(PbO) 기반의 X-ray Detector film의 개발에 있어서 각각 HgI2 및 PbO 두 물질 층을 적정비율에 맞추어 제작함으로써 최적의 X-ray Detector를 구현하고자 하였다. 이는 빠른 영상획득을 통해 기존의 방식이 가지는 문제점을 해결하고 의료기기 디지털화를 구현할 수 있는 차세대 시스템을 개발하고자 하는 것이다. 본 연구에서는 기존의 진공증착법의 두꺼운 대면적 필름의 제조가 어려운 문제점을 해결하고자 Particle In Binder method(PIB) 방법을 이용하여 $3"{\times}3"$사이즈의 두께 $200{\mu}m$의 다결정의 Photoconductor 필름을 제조하여 전기적 특성을 평가하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 기준 실험으로 진행한 DG 2.1 바인더를 사용한 single-HgI2 층에서 보다 높은 sensitivity 값을 보였지만 높은 dark current로 인해 SNR이 떨어지는 결과를 볼 수 있었다. 본 연구에서 제시하는 두 Photoconductor material의 Soaking method를 이용한 실험에서는 single-HgI2에 해당하는 높은 sensitivity 및 저감된 dark current로 인해 높은 SNR 값을 획득하였다. 하지만 습도와 같은 주변 환경에 의한 재현성 문제로 인한 신호값의 불안정성에 대한 문제점도 남아 있으므로, 차후 최적화된 material 제작 공정을 위한 연구가 꾸준히 진행 되어져야 할 것이다.

  • PDF