• Title/Summary/Keyword: 2근관

Search Result 1,013, Processing Time 0.024 seconds

Impact of Distress and Stigma on Quality of Life among Patients with Cerebrovascular Disease (뇌졸중 환자의 디스트레스와 스티그마가 삶의 질에 미치는 영향)

  • Lee, Kyoung Hee;Jeon, Jaehee
    • Journal of muscle and joint health
    • /
    • v.31 no.2
    • /
    • pp.95-106
    • /
    • 2024
  • Purpose: This study investigated how distress and stigma affect the quality of life (QOL) in stroke patients. Methods: A descriptive research design was utilized with 150 stroke patients from three general and three long-term care facilities. Data were collected through an 86-item questionnaire from February 15 to April 10, 2023, using measures of distress, stigma, and QOL. Analysis was conducted using descriptive statistics, independent t-tests, one-way ANOVA, Pearson's correlation coefficients, and hierarchical regression analysis in SPSS/WIN 25.0. Results: The average QOL score was 156.37±38.27 out of 245 points. Factors affecting QOL of stroke patients were distress (β=-.56, p<.001), stigma(β=-.26, p<.001), biplegia (β=-.11, p=.045), and unemployment (β=-.10, p=.045), explaining 68% of the QOL variance. Conclusion: Programs aimed at reducing distress and stigma in stroke patients are essential for enhancing QOL. Effective strategies should address post-stroke physical and mental states, prevent complications, restore health, reduce anxiety, and leverage family and social support to mitigate stigma. Special attention is needed for stroke patients with hemiplegia and those who are unemployed.

Effect of Eldercare Facility Care Workers' Person-centered Care and Patient Safety Culture on Fall Prevention Behavior of Older Adults with Dementia (노인요양시설 요양보호사의 인간중심돌봄과 환자안전문화가 치매노인 낙상예방행위에 미치는 영향)

  • Byeon, Sukyung;Kang, Kyung Ja
    • Journal of muscle and joint health
    • /
    • v.31 no.2
    • /
    • pp.126-136
    • /
    • 2024
  • Purpose: This study aimed to investigate the level of person-centered care, patient safety culture, and fall prevention behaviors of eldercare facility workers, and identify influencing factors. Methods: Data were collected from 185 care workers at eight eldercare facilities in City J from February 1 to March 25, 2022. The data were analyzed using SPSS/WIN 25.0. Results: The results indicated that the factors influencing fall prevention behaviors in older adults with dementia were person-centered care (β=.28, p=001), patient safety culture (β=.21, p=.012), age (β=-.18, p=.005), and participation in fall prevention education (β=-.15, p=.018). The explanatory power of the model was 31.6%. Conclusion: These results suggest that, to improve fall prevention behaviors in older adults with dementia, efforts to promote person-centered care and patient safety culture are necessary. Accordingly, effective measures such as developing fall prevention education and programs should be explored to provide safe and high-quality care for older adults with dementia.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Debris removal efficiency depend on different ultrasonic irrigation protocols (초음파 세정 프로토콜에 따른 근관 내 잔사 제거의 효율성 비교)

  • Heo, Gun;Kim, Jin-Woo;Cho, Kyung-Mo;Enkhbileg, Nyamsuren;Lee, Eun-Hye;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.104-111
    • /
    • 2020
  • Purpose: The purpose of this study is comparing the efficiency of debris removal of passive ultrasonic irrigation depend on different protocols. Materials and Methods: Forty-eight mandibular premolars were randomly divided into 2 groups depend on vibration power (Weak and Strong, n = 24). And then two groups were subdivided into 3 groups depend on the number of times that PUI used (1, 2 and 3, n = 8). After standardization, teeth were split into two halves. On the wall of one half of root canal, three depressions were cut at 1, 3 and 5 mm from the apex and in the same way two depressions were cut on the other half of root canal at 2, 4 mm from the apex. Each depression was filled with mixture of dentine and NaOCl. After irrigation, images of the root canal wall were taken, and then the amount of remaining dentine debris was evaluated. Results: There was no significant difference between weak and strong power of vibration groups. Weak vibration groups did not show significant difference depend on the different number of times PUI used. But in the strong vibration groups, twice and three times used groups show better removal efficiency. Conclusion: The removal efficiency of dentine debris is not significantly different depend on the power of vibration. And multiple use of PUI could have better irrigating effects at the apical third area in the strong vibration group.

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

Application of dental microscope in endodontic treatment procedure. (근관치료 영역에서 치과용 미세현미경의 활용)

  • Choi, Sung Baik
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.542-555
    • /
    • 2017
  • 1. Diagnosis Diagnosis of Crack, Direct pulp capping 2. Access opening Find the calcified canal orifice Removal of dentin shelf Obtaining the MB2 canal (MB2, MB3, DB2) 3. Perforation repair during endodontic treatment 4. Removal of the separated files 5. Open apex treatment 6. Void removal on CWT procedure 7. Re-endodontic treatment Removal of restorative material filled in pulp chamber Post removal Identification and removal of residual gutta-perch 8. Surgical endodontic treatment In each case will overview how to use a dental microscope.

  • PDF

A comparison of chlorhexidine release rate from three polymeric controlled release drug prototypes (제어방출형 소독제의 약물전달 체로 사용된 폴리머 유형에 따른 클로르헥시딘 제어 방출속도 비교)

  • Bok Young-Bin;Lee Doug-Youn;Lee Chang-Young;Kim Kyung-Nam;Kum Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.548-552
    • /
    • 2004
  • Intracanal disinfection of infected root canal is one of important treatment procedure. This in vitro study aimed to evaluate whether the surface polymers of controlled release drug (CRD) can effectively control the release rate of chlorhexidine for root canal disinfection. Four CRD prototypes were prepared: Group A (n=12); The core device (absorbent paper point) was loaded with 40% CHX solution as control. Group B (n=12); same as group A, but the device was coated with chitosan. Group C (n=12); same as group A and then coated three times with 5% PMMA. Group D (n=12); same as group A and then coated three times with 3% PLGA. All CRD prototypes were soaked in 3 mL distilled water for experimental periods and the concentrations of released CHX from each CRD prototype were determined using a UV spectrophotometer. Results showed that release rate of CHX were the greatest in the non-coated group (control group), followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). This data indicate that surface polymers can control the release rate of CHX from the CRD prototypes.

Clinical Factors Affecting the Results of Regenerative Endodontic Procedure (재생근관치료 결과에 영향을 미치는 인자의 분석)

  • Kim, In-Ki;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.449-459
    • /
    • 2021
  • This study retrospectively analyzed the effect of clinical factors on the outcomes of REP(regenerative endodontic procedure). Patients who received the REP using triple antibiotic paste due to trauma or fracture of dens evaginatus from February, 2011 to January, 2020 were included in the study. Finally, 57 teeth in 54 patients were selected. Investigated clinical factors were as follows: intentional bleeding, etiology, and root development stage. Treatment outcomes evaluated were as follows: improvement of subjective symptoms, changes in the periapical lesion, and the amounts of root development after REP. To compensate for differences in angulation and position between repeated radiographic examinations, images were aligned by Turboreg plugin. To evaluate the amounts of root development, apical diameter, root area, and root length were measured by ImageJ software. Among the aforementioned factors, intentional bleeding had no significant effect on treatment results. Regarding the etiology, the increase in the root area and the root length was significantly less in trauma cases than in dens evaginatus fracture cases. Considering root development stage, more immature teeth presented more increase in the root area.

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.