• Title/Summary/Keyword: 2,4-dinitrophenylhydrazine

Search Result 47, Processing Time 0.025 seconds

Fish Oil Enriched Diet-Induced in vivo Lipid Peroxidation and Increased Excretion of Urinary Lipophilic Lipid Metabolites in Rats

  • Kim, Song-Suk
    • Nutritional Sciences
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2000
  • Peroxidative stimuli mediated by high polyunsaturated fatty acid administration in rats induced in vivo lipid peroxidation and resulted in increased urinary excretion of a number of lipophilic aldehydes and related carbonyl compounds. These secondary lipid peroxiation products, measured as 2, 4-dinitrophenylhydrazine deritives, were detected and identified by the newly developed HPLC method. The identified urinary lipophilic nonpolar aldehydes and related carbonyl compounds were butanal, butan-2-one, pentan-2-one, hexanal, hex-2-enal, hepta-2, 4-dienal, hept-2-enal, octanal, and oct-2-enal. Lipophilic polar aldehydes such as 4-hydroxyhex-2-enal and 4-hydroxyoct-2-enal were also identified. A polyunsaturated fatty acid diet containing n-3 fatty acids generally caused high levels of urinary excretion of lipophilic aldehydes and related carbonyl compounds in rats than a normal diet. Significantly increased secondary lipid peroxidation products were hexanal, hepta-2, 4-dienal, octanal, 4-hydroxyhex-2-exal, 4-hydroxyoct-2-enal, and a number of unidentified compunds.

  • PDF

Characteristics of Formaldehyde Concentrations in the Underground Spaces in Gyungnam Province (경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성)

  • Ha Kwon Chul
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.353-357
    • /
    • 2004
  • The purpose of this research is to characterize formaldehyde as trace toxic air pollutant in the underground spaces in Gyungnam province. Air samples of formaldehyde were taken in the three underground spaces for ten months from April 2003 to January 2004. The IAQ(Indoor Air Quality) of underground spaces were controled using central ventilation(supply/exhaust) system. The levels of GM of airborne formaldehyde concentrations in three sampling spaces were well below applicable standards, Korean Ministry of Environment, 0.1 ppm. However, some sample of airborne formaldehyde concentrations in underground spaces 'B' and 'C' were in excess of standard, due to the commercial products in shop, structural material, and the climate having high humidity and temperature. There are statistical differences in levels of formaldehyde by sampling spaces (p=0.086).

A Study on the Peak Separation of Acetone and Acrolein Based on High-Performance Liquid Chromatography (HPLC) Method

  • Kim, Shin-Do;Kim, Chang-Hwan;Park, Jin-Su;Lee, Jeong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2011-2016
    • /
    • 2009
  • To resolve the differentiation problem of acetone and acrolein in the analysis of carbonyls by high-performance liquid chromatography (HPLC), we investigated the optimum analytical conditions for their separation. Carbonyl compounds were collected by 2,4-dinitrophenylhydrazine (DNPH)-coated cartridges. We examined the influence of three experimental variables: temperature (25, 30, 40, 50 and 60 ${^{\circ}C}$), flow rate (1.0 and 1.2 mL/min), and relative mobile phase composition (among acetonitrile, water and tetrahydrofuran). The experimental results revealed the optimum analytical condition of a flow rate of 1.2 mL/min, temperature of 32 ${^{\circ}C}$ and mobile phase composition of acetonitrile: water: tetrahydrofuran = 34 : 52.8 : 13.2. The analysis of indoor air composition indicated that acrolein and acetone comprised 11% and 42% of all aldehydes, respectively.

Selective Adsorption Properties of Carbonyl Compounds in Cigarette Mainstream Smoke by Hydrazine Impregnated Adsorbent (Hydrazine 첨착 흡착제에 의한 담배 주류연 중 카보닐 화합물의 선택 흡착 특성)

  • Park Jin-Won;Rhee Moon-Soo;Lee John-Tae;Hwang Keon-Joong;Hwang Taek-Sung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.2
    • /
    • pp.178-188
    • /
    • 2005
  • To use the filter materials for selective removal of carbonyl compounds in cigarette mainstream smoke, hydrazine such as 2,4-dinitrophenylhydrazine and dansylhydraznie impregnated adsorbents were prepared with perchloric acid or phosphoric acid as a accelerator in hydrazone formation reaction. The change of morphology of adsorbents in various of impregnator were investigated by SEM. Impregnation amount caused by reaction time, acid type and impregnation reagent, and the adsorption properties of carbonyl compounds in cigarette mainstream smoke were investigated. Amounts of impregnation was increased as increasing reaction time. The removal amount for vapor phase carbonyl compounds by 2,4-DNPH impregnated adsorbent was higher than that of dansylhydrazine impregnated adsorbent. The selectivity of 2,4-DNPH impregnated polyacrylic type adsorbent was superior to those of other adsorbents. This results indicated that the 2,4-DNPH impregnated polyacrylic adsorbent was applicable to cigarette filter material because of its fast reactivity and porosity.

Sample Development for Quality Control of Formaldehyde and Proficiency Analytical Testing (정도관리용 포름알데히드 시료개발 및 분석능력평가)

  • Park, Hae Dong;Jang, Miyeon;Park, Seunghyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Objectives: The objective of this study was to develop formaldehyde samples for quality control (QC) and to test the applicability of proficiency analytical testing in Korea. Methods: We made formaldehyde samples with certified standard solutions (formaldehyde in water or acetonitrile) and 2,4-dinitrophenylhydrazine (2,4-DNPH)-coated silicagel tubes. Four levels of formaldehyde concentration were tested for storage stability at room temperature and at 4℃ over three months. Analytical proficiency testing was performed with four or 36 institutes. Results: Formaldehyde sample tubes were easily made through the injection of standard solutions and the average efficiencies of recovery were 95-101%. The coefficients of variation (CV) of the formaldehyde samples were 1.39-2.55%. The recovery efficiencies fell between 90% and 110% at the concentration range of 1-10 ㎍/sample over three months storage at refrigerated and room temperature. The CVs were less than 5% in the proficiency analytical testing. By adjusted proficient ranges, 64% of the results of the second proficiency analytical testing were acceptable. Conclusions: The formaldehyde samples made by injection on 2,4-DNPH-coated silicagel tubes were stable and applicable for quality control.

Comparison of Chromotropic Acid Method and DNPH-HPLC Method for the Measurement of Formaldehyde in the Air (공기 중 포름알데히드 측정을 위한 크로모트로핀산법과 DNPH/HPLC방법의 비교.평가)

  • Hwang, Yun-Jeong;Park, Sang-Gon;Baek, Seong-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.519-524
    • /
    • 1998
  • Formaldehyde is known to have adverse health effects, and is also found to be a product of atmospheric. photochemical reaction%. Several methods have been employed for the measurement of formaldehyde. Among them, two common methods are comparatively evaluated in this study, i.e. the chromotropic acid method and the HPLC method coupled with 2,4- dinitrophenylhydrazine (DNPH) derivatization of carbonyl compounds. Method evaluation and validation were performed with respect to repeatability, linearity, collection efficiency, and recovery efficiency. Comparison of formaldehyde concentrations measured simultaneously in the field using the two (n=20) and 35.8%, respectively. Overall, the measured levels by chromotropic acid method appeared to ice significantly higher than those by DNPH-HPLC method, indicating a positive interference due to the other aldehydes collected together with formaldehyde.

  • PDF

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Suntae
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

An Integrated Air Monitoring Approach for Assessment of Formaldehyde in the Workplace

  • Dugheri, Stefano;Bonari, Alessandro;Pompilio, Ilenia;Colpo, Marco;Mucci, Nicola;Arcangeli, Giulio
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2018
  • The aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.12 ppm, using dynamically generated FA air concentrations. Simple linear regression analysis showed the four methods were suitable for evaluating airborne FA. Personal and area samplings in 12 anatomy pathology departments showed that the international occupational exposure limits in the GESTIS database were frequently exceeded. This monitoring approach would allow a fast, easy-to-use, and economical evaluation of both current work practices and eventual changes made to reduce FA vapor concentrations.

Antioxidant Activity of Gomchi (Ligularia fischeri) Leaves

  • Choi, Eun-Mi;Ding, Van;Nguyen, Huu Tung;Park, Sang-Heock;Kim, Young-Ho
    • Food Science and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.710-714
    • /
    • 2007
  • Ligularia fischeri (LF) has been used to treat jaundice, scarlet-fever, rheumatoidal arthritis, and hepatic diseases. This study was carried out to determine the antioxidant activity of the extract from the leaves of LF by using various established in vitro systems with ${\alpha}$-tocopherol as positive control. The results showed that the ethanol extract of LF (0.05-0.5 mg/mL) displayed a strong free radical scavenging activity against 1,1-diphenyl-2-picrylhydrazyl, ${O_2}^{{\cdot}-}$, and $H_2O_2$ radicals. It was observed that LF extract (1 mg/mL) significantly decreased the levels of malondialdehyde (MDA) to 69 and 89% of control, measured by ferric thiocyanate (FTC) and thiobarbituric acid (TBA) test, respectively. LF extract (0.5-2 mg/mL) was also found to inhibit significantly the amount of malondialdehyde formed from liver homogenate to 69-56% of control. Similarly, in the high $Fe^{2+}/ascorbate$ induction system LF extract (1-2 mg/mL) inhibited carbonyl formation measured by 2,4-dinitrophenylhydrazine reaction to 89-79% of control. Like antioxidant activity, the reducing power of LF extract was excellent at concentration of 0.5-2 mg/mL. These results indicate that LF could be used as a potential source of natural antioxidant.

Kinetics Study of the Reaction of Bromine with Phenylhydrazine in Sulfuric Acid Media (페닐히드라진과 브롬의 반응메카니즘에 관한 연구)

  • Park Byoung Bin;Park Il H.;Kong Young Kun;Choi Q. Won
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.227-234
    • /
    • 1977
  • The reaction of phenylhydrazine with bromine in sulfuric acid solution has been studied kinetically. The pseudo-second-order rate constant is approximately inversely proportional to hydrogen-ion concentration when the concentration of sulfuric acid is lower than 1M. arom the study of the effect of potassium bromide concentration on the rate constant, it is concluded that both neutral bromine and tribromide ion participate in the reaction, the rate constants in 0.01M $H_2SO_4$ being $5{\times}10^5M^{-1},sec^{-1}\;and\;0. 7{\times}10^5M^{-1},sec^{-1}$, respectively at $20^{\circ}C$. The pseudo-second-order rate constant of 2.4-dinitrophenylhydrazine-bromine reaction is independent of hydrogen ion concentration. From the KBr addition experiment, the rate constants for $Br_2\;and\;Br_3^-$ were obtained as $1.2{\times}10^5M^{-1},sec^{-1}\;and\;2.0{\times}10^4M^{-1},sec^{-1}$, respectively.

  • PDF