DOI QR코드

DOI QR Code

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen (Research & Development Center, NINECO Inc.) ;
  • Lee, Kyusung (Research & Development Center, NINECO Inc.) ;
  • Kim, Jooin (Research & Development Center, NINECO Inc.) ;
  • Hong, Hyunsu (Research & Development Center, NINECO Inc.) ;
  • Kim, Suntae (Department of Environmental Engineering, Daejeon University)
  • Received : 2012.08.17
  • Accepted : 2013.05.09
  • Published : 2013.09.30

Abstract

The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

Keywords

References

  1. World Health Organization, Regional Office for Europe. Air quality guidelines for Europe. 2nd ed. Copenhagen; World Health Organization, Regional Office for Europe; 2000.
  2. US Consumer Product Safety Commission. An update on formaldehyde. Washington: US Consumer Product Safety Commission; 1997.
  3. Marchand C, Bulliot B, Le Calve S, Mirabel Ph. Aldehyde measurements in indoor environments in Strasbourg (France). Atmos. Environ. 2006;40:1336-1345. https://doi.org/10.1016/j.atmosenv.2005.10.027
  4. Baez A, Padilla H, Garcia R, Torres Mdel C, Rosas I, Belmont R. Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico. Sci. Total Environ. 2003;302:211-226. https://doi.org/10.1016/S0048-9697(02)00344-3
  5. Clarisse B, Laurent AM, Seta N, Le Moullec Y, El Hasnaoui A, Momas I. Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings. Environ. Res. 2003;92:245-253. https://doi.org/10.1016/S0013-9351(03)00039-2
  6. Gillett RW, Kreibich H, Ayers GP. Measurement of indoor formaldehyde concentrations with a passive sampler. Environ. Sci. Technol. 2000;34:2051-2056. https://doi.org/10.1021/es990929n
  7. US Environmental Protection Agency. A comparison of indoor and outdoor concentrations of hazardous air pollutants. In: Inside IAQ: EPA's indoor air quality research update (EPA/600/N-98/002). Durham: US Environmental Protection Agency; 1998. p. 1-7.
  8. Zhang J, Lioy PJ, He Q. Characteristics of aldehydes: concentrations, sources, and exposures for indoor and outdoor residential microenvironments. Environ. Sci. Technol. 1994;28:146-152. https://doi.org/10.1021/es00050a020
  9. Korea Ministry of Environment. Indoor air quality control in public use facilities, etc. Act. Article 5: standards for maintenance of indoor air quality, etc. Gwacheon: Korea Ministry of Environment; 1997.
  10. Kim ST, Yim B, Jeong J. Evaluation of a passive air sampler for measuring indoor formaldehyde. Anal. Sci. 2007;23:497-500. https://doi.org/10.2116/analsci.23.497
  11. Yim B, Jung E. Badge-type diffusive sampler using 3-methyl- 2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air. Anal. Sci. 2006;22:993-997. https://doi.org/10.2116/analsci.22.993
  12. Lodge JP. Methods of air sampling and analysis. 3rd ed. Boca Raton: Lewis publishers; 1988.
  13. Levin JO, Andersson K, Lindahl R, Nilsson CA. Determination of sub-part-per-million levels of formaldehyde in air using active or passive sampling on 2,4-dinitrophenylhydrazinemethods coated glass fiber filters and high-performance liquid chromatography. Anal. Chem. 1985;57:1032-1035. https://doi.org/10.1021/ac00283a016
  14. Gorecki T, Namiesnik J. Passive sampling. Trends Anal. Chem. 2002;21:276-291. https://doi.org/10.1016/S0165-9936(02)00407-7
  15. United Nations Environment Programme; World Health Organization. GEMS/AIR methodology review handbook Series. Vol. 4: Passive and active sampling methodologies for measurement of air quality. Nairobi: United Nations Environment Programme; 1994.
  16. Ellison SL, Rosslein M, Williams A; Eurachem/CITAC Working Group. Quantifying uncertainty in analytical measurement. 2nd ed. Uppsala: Eurachem; 2000.
  17. Plaisance H, Leonardis T, Gerboles M. Assessment of uncertainty of benzene measurements by Radiello diffusive sampler. Atmos. Environ. 2008;42:2555-2568. coated glass fiber filters and high-performance liquid chromatography. Anal. Chem. 1985;57:1032-1035. https://doi.org/10.1021/ac00283a016
  18. Gorecki T, Namiesnik J. Passive sampling. Trends Anal. Chem. 2002;21:276-291. https://doi.org/10.1016/S0165-9936(02)00407-7
  19. United Nations Environment Programme; World Health Organization. GEMS/AIR methodology review handbook Series. Vol. 4: Passive and active sampling methodologies for measurement of air quality. Nairobi: United Nations Environment Programme; 1994.
  20. Ellison SL, Rosslein M, Williams A; Eurachem/CITAC Working Group. Quantifying uncertainty in analytical measurement. 2nd ed. Uppsala: Eurachem; 2000.
  21. Plaisance H, Leonardis T, Gerboles M. Assessment of uncertainty of benzene measurements by Radiello diffusive sampler. Atmos. Environ. 2008;42:2555-2568. https://doi.org/10.1016/j.atmosenv.2007.12.009

Cited by

  1. Environmental Engineering Research in September 2013 pp.2005-968X, 2013, https://doi.org/10.4491/eer.2013.18.3.115