• Title/Summary/Keyword: 2,4-DCP oxidation

Search Result 13, Processing Time 0.019 seconds

Effects of Nitrate Ions on Advanced Oxidation of UV/H2O2 for 2,4-Dichlomphenol Degradation (UV/H2O2를 이용한 2,4-DCP의 산화에 NO3- 이온이 미치는 영향)

  • Park, Jae Han;Lee, Ji Yong;Ahn, Yoon Hee;Moon, Tae Hoon;Yim, Sung Kyun;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.319-323
    • /
    • 2007
  • The Advanced Oxidation Process (AOP) is being increasingly used to oxidize complex organic constituents in treated effluents from domestic wastewater treatment plants. Generally, ${NO_3}^--N$ concentrations ranges between 5 and 8 mg/L for biologically well-treated effluents. However, nitrate ions, ${NO_3}^-$, affects on oxidation as not only a well-known strong absorber of UV light below 250 nm of wavelength but also as an OH radical scavenger. The objective of this study was to evaluate the AOP systems for degradation of 2,4-DCP, and to delineate the effect of nitrate ions on UV oxidation of 2,4-DCP by conducting a bench-scale operation at various reaction times and initial concentrations of $H_2O_2$. The experimental results indicated that 2,4-DCP could be completely oxidized by $UV/H_2O_2$ process with an initial $H_2O_2$ concentration of 20 mg/L at a retention time of 1.0 min or longer. Nitrate ions did not show any adverse effect on 2,4-DCP oxidation at this high $H_2O_2$ concentration, and the practical initial $H_2O_2$ concentration and reaction time for the 80% oxidation turned out to be 5 mg/L and 1.0 min, respectively.

Development of On-Site Process for Refractory 2,4-Dichlorophenol Treatment (난분해성 2,4-Dichlorophenol 처리를 위한 원위치 처리 프로세스 개발 연구)

  • Park, Kyeong-Deok;Kim, Il-Kyu
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.42-49
    • /
    • 2016
  • This study showed that on-site ferrate(VI) solution was synthesized by wet oxidation method and applied aqueous 2,4-dichlorophenol(DCP) solution to evaluate the degradation efficiency. On-site ferrate(VI) solution was synthesized by putting $FeCl_3{\cdot}6H_2O$ in the strong alkali solution with NaClO and NaOH and applied DCP solution directly. DCP solution was extracted by the liquid-liquid method and analyzed by GC-ECD. The factors such as pH, DCP initial concentration, injected ferrate(VI) dosage, temperature were investigated. The optimum pH and temperature conditions of DCP degradation were obtained in neutral condition and $35^{\circ}C$. And the experimental results showed that DCP removal efficiency also increased with the decrease of DCP initial condition and the injected ferrate(VI) dosage.

Isolation and Characterization of Soil Streptomyces Involved in 2,4-Dichlorophenol Oxidation

  • Kang, Min-Jin;Kang, Ja-Kyoung;Kim, Eung-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.877-880
    • /
    • 1999
  • Over 50 morphologically distinctive soil Streptomyces were isolated from various Jocations in the Yongin area in Korea and visually screened for dye-decoloring activities on an agar plate. Two Streptomyces species (AD001 and ND002) showed strong dye-decoloring activities on the plate containing congo-red and new-fuchin dyes, respectively. Also, the liquid culture supernatants of these species showed 2,4-dicholophenol (DCP) oxidation activities only in the presence of hydrogen peroxide, a characteristic of Actinomycetes lignin-peroxidase (ALiP)-P3 isoform found in dye-degrading S. viridosporus T7A and S. badius 252. Based on their dye-decoloring capabilities and the 2,4-DCP oxidation kinetic data, it is suggested that these Streptomyces secrete not-yet-characterized extracelluar enzyme(s), whose activities are very similar to the ALiP-P3 enzyme.

  • PDF

Characteristics of TCE, Benzene & 2,4 Dichlorophenol Degradation in Aqueous solution by Ulrasonic Irraditation (초음파 조사에 의한 수중의 TCE, Benzene & 2,4 Dichlorophenol의 분해 특성)

  • 손종렬;모세영
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.33-41
    • /
    • 1996
  • This study was performed to examine the factors influencing on the degradation of TCE, Benzene and 2,4 DCP in aqueous solution using ultrasonic irradiation. The TCE,Benzene and 2,4 DCP, which are hazard compounds causing environmental pollution, were not decomposable pollutants by convientional treatment. The results shows that the generation of H$_{2}$O$_{2}$, H$^{+}$ and OH$^{-}$ radical was formed by the oxidation and reduction reaction of ultrasound, and then theses decomposed the refractory pollutants of TCE, Benzene & 2,4 DCP in aqueous solution. we conformed that the ultrasonic irradiation was excellent in removal efficiency of the refractory pollutants any other than Advanced Oxidation Processes(AOP), utilized the treatment of organic compounds in the industrial wastewater. Consequently, these results suggest that ultrasonic irradiation may be extremely useful for the treatment of wastewaters contaminated organic pollutants, which is difficult to treat economically by conventional process.

  • PDF

Application for Degradation of 2,6-dichlorophenol by in-situ Synthesized Liquid Ferrate(VI) (원위치 제조 액상 Ferrate(VI)를 이용한 2,6-dichlorophenol의 분해적용 연구)

  • Gwak, Bo-ra;Kim, Il-kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.705-711
    • /
    • 2015
  • Degradation of 2,6-Dichlorophenol (DCP) using liquid ferrate(VI) synthesized by wet oxidation method has been studied. Several parameters such as pH (acid, base and neutral), DCP initial concentration, ferrate dosage, and temperature have been examined to determine the optimal experimental conditions. The ferrate(VI) has useful properties such as strong oxidizing power and selectivity and generates a non-toxic end product, Fe(III). Ferrate ion reduced rapidly to Fe(III) and oxygen in acidic and neutral conditions. The experimental results showed the higher DCP degradation efficiency in the neutral condition than in the acidic and basic conditions. The oxidation of DCP strongly depended on the dosage of ferrate added to the reactor and DCP initial concentration. With increasing of ferrate dosage the degradation efficiency of DCP increased, while the degradation efficiency of DCP decreased with increasing of DCP initial concentration. The effect of temperature has been tested at 4 different levels (10, 25, 35, and $50^{\circ}C$). The optimal temperature was obtained in $25^{\circ}C$ and degradation efficiency decreased as the temperature increased in the range from $25^{\circ}C$ to $50^{\circ}C$. The DCP degradation pathways were studied and proposed based on the intermediate products identified by GC/MS analysis.

A Study on Oxidative Degradation of Chlorophenols by Heat Activated Persulfate (열적활성화된 과황산에 의한 염화페놀의 산화분해특성 연구)

  • Son, JiMin;Kwon, Hee-Won;Hwang, Inseong;Kim, Jeong-Jin;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.29 no.1
    • /
    • pp.69-77
    • /
    • 2020
  • Oxidative degradation of phenol, three monochlorophenols (2-chlorophenol, 2-CP; 3-chlorophenol, 3-CP; 4-chlorophenol, 4-CP), four dichlorophenols (2,3-dichlorophenol, 2,3-DCP; 2,4-dichlorophenol, 2,4-DCP; 2,5-dichlorophenol, 2,5-DCP; 2,6-dichlorophenol, 2,6-DCP), and two trichlorophenols (2,4,5-trichlorophenol, 2,4,5-TCP; 2,4,6-trichlorophenol, 2,4,6-TCP) was conducted with heat activated persulfate. As the number of chlorinations increased, the reaction rate also increased. The reaction rate was relatively well fitted to the zero-order kinetic model, rather than the pseudo-first order kinetic model for the reactions at 60 ℃, which can be explained by insufficient activation of the persulfate at 60 ℃, and the oxidation reaction of 2,4,6-TCP at 70 ℃ was relatively well fitted to the pseudo-first order kinetic model. The oxidation reaction rate generally increased with increase of persulfate concentration in the solution. 2,6-dichloro-2,5-cyclohexadiene-1,4-dione was found as a degradation product in a GC/MS analysis. This compound is a non-aromatic compound, and one chlorine was removed. This result is similar to the result of previous studies. The current study proved that heat activated persulfate activation could be an alternative remediation technology for phenol and chlorophenols in soil and groundwater.

Rapid Screening Method of Peroxidase by Colorimetric Assay and Screening of 2, 4-DCP Degradable Strains (발색법에 의한 Peroxidase의 신속한 스크리닝법과 2, 4-DCP 분해균주의 스크리닝)

  • Ryu, Kang;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.23 no.6
    • /
    • pp.484-488
    • /
    • 2008
  • Chlorinated phenols are widely used by the chemical industry as intermediate products in synthesis and previously were frequently applied to various industry fields. Peroxidases catalyze the peroxide-dependent oxidation of a range of inorganic and organic compounds. Peroxidase was shown to mineralize a variety of recalcitrant aromatic compounds and to oxidize a number of polycyclic aromatic and phenolic compounds. Among monomeric phenolic and nonphenolic compounds, peroxidase is known to oxidize its compounds. In this study, a colorimetric assay was developed to quantitatively evaluate the peroxidase activity for rapid screening. Color products of different intensity were developed proportionally to the peroxidase activity on agar plate and 96-well plate. This method correlates well with the RP-HPLC result. Using this screening method, 12 colonies of strain was screened which survived at high concentration of 2,4-DCP (1000 ppm) and with peroxidase activity for the $7^{th}$ round screening step on agar plate. These strains were utilized 2,4-DCP as a sole carbon source and produced peroxidase. After the screening test, four of the bacteria have significant better effect of COD removal on dye waste-water. COD removal of these was from 44% to 61%, respectively.

Characteristics of Decomposition for Refractory Organic Compounds in Aqueous Solution by Sonolysis and Electrolysis (초음파와 전기분해를 이용한 수중의 난분해성 유기물질의 분해 특성)

  • Jeong, Jae-Baek;Lee, Seong-Ho;Bae, Jun-Ung
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.6
    • /
    • pp.454-463
    • /
    • 2006
  • refractory organic compounds in aqueous solution are not readily removed by the existing conventional wastewater treatment process. In recent years, the sonolysis and electrochemical oxidation process had been shown to be promising for wastewater treatment due to the effectiveness and easiness in operation. This study was performed to investigate the characteristics of sonolytic and electrolytic decomposition as the basic data for development of the wastewater treatment process. Trichloroethylene(TCE) and 2,4- dichlorophenol(2,4-DCP) were used as the samples, and their destruction efficiency were measured with various operating parameters, such as initial solution concentration, initial solution pH, reaction temperature, sonic power and current density. Also, the decomposition mechanism conformed indirectly with the effect of NaHCO3 as a radical scavenger on the decomposition reaction. Thermal decompositon reaction is predominant for TCE but thermal and radical decompositon reactions were dominant for 2,4-DCP. Results showed that the destruction efficiencies of all samples were above 65% within 120 minutes by sonolysis and electrolysis at the same time, and were increased with increasing initial concentration, sonic power and current density. Destruction efficiency of TCE was high in the acidic solution, but 2,4-DCP showed high destruction efficiency in basic solution.

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.

Purification and Characterization of 2,4-Dichlorophenol Oxidizing Peroxidase from Streptomyces sp. AD001

  • Jeon, Jeong-Ho;Yun-Jon Han;Tae-Gu kang;Eung-Soo Kim;Soon-Kwang Hong;Byeong-Chul Jeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.6
    • /
    • pp.972-978
    • /
    • 2002
  • Streptomyces sp. AD001 is a Gram-positive soil actinomycetes secreting an uncharacterized 2,4-dichlorophenol (DCP) oxidizing enzyme, whose activity is similar to the previously known Actinomycetes lignin-peroxidase (ALiP). This extracellular peroxidase was purified from Streptomyces sp. AD001 as a single protein band on an SDS-PACE by ammonium sulfate fractionation, Q-sepharose, concanavalin A, and Bio-Gel HTP column chromatographies. The molecular mass of the purified peroxidase was determined by SDS-PAGE to be 45.2 kDa, and 49.7 kDa with MALDI-TOF-MS, respectively. The highest level of peroxidase activity was observed at pH 7.5 and $30^{\circ}C$. The amino terminal sequence of the purified peroxidase (G-E-P-E-E-G-N-V-D-G-T-L) showed no significant homologies to my known proteins, suggesting that Streptomyces sp. AD001 may secrete a novel kind of bacterial peroxidase Initial rate kinetic data of the 2,4-DCP oxidation were best modeled with a random-binding bireactant system.