• Title/Summary/Keyword: 14dB

Search Result 2,434, Processing Time 0.028 seconds

Design and Fabrication of Ku-Band Power Amplifier Using GaN HEMT Die (GaN HEMT Die를 이용한 Ku-대역 전력 증폭기 설계 및 제작)

  • Kim, Sang-Hoon;Kim, Bo-Ki;Choi, Jin-Joo;Jeong, Byeoung-Koo;Tae, Hyun-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.6
    • /
    • pp.646-652
    • /
    • 2014
  • This paper presents a design and fabrication of Ku-band power amplifier using Gallium Nitride High Electron Mobility Transistor (GaN HEMT) die. In order to fabricate the low-cost Ku-band power amplifier, a Printed Circuit Board(PCB) was used for input/output matching circuits instead of manufacturing process to use an expensive substrate. The measured output power is 42.6 dBm, the drain efficiency is 37.7 % and the linear gain is 7.9 dB under pulse operation at the frequency of 14.8 GHz. Under the continuous wave(CW) test, the output power is 39.8 dBm, the drain efficiency is 24.1 % and the linear gain is 7.2 dB.

The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses (단초점 근용 안경의 수평방향 설계점 결정에 대한 이해)

  • Kim, Min Ho;Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purpose of this study is to compare degrees of asthenopia in after wearing of dispensed reading glasses with different criterion of P.D. Methods: The person who has minus near correction power (distance correction value (-)) is compared to the degree of asthenopia by wearing of dispensed reading glasses with near P.D(-B) and distance P.D. The person who has plus near correction power is compared to degree of asthenopia by wearing of dispensed reading glasses with near P.D-B, distance P.D, near P.D-A. The "Near-P.D-A" means reduced optical centre distance of reading glasses of positive correction value at which the same effect of prism B.O through near visual point in distance glasses exist at near visual point in reading glasses. Results: When near correction value is (-), dispensed reading glasses with distance P.D have caused less asthenopia than dispensed glasses with near P.D-B. When the near correction value is (+), we cannot confirm that which P.D is more useful for reading glasses. As a result of this study, dispensed reading glasses with near P.D-A have caused less asthenopia than another criterion of P.D. Conclusion: The effect of prism B.I through a near visual point in distance glasses ((-) correction value) reduce convergence demand. Therefore (-) correction value-reading glasses support convergence in near vision, because the effect of prism B.I of reading glasses is smaller than that of distance glasses. When the near correction value is (+), centration points can be determined by one of near P.D-A, near P.D-B, distance P.D.

  • PDF

Fracture Characteristics of the Resistance Spot Welded Joints by Acoustic Emission (음향방출법에 의한 저항 점용접부의 파괴특성에 대한 연구)

  • Jo, Dae-Hee;Rhee, Zhang-Kyu;Park, Sung-Oan;Kim, Bong-Gag;Woo, Chang-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.14-22
    • /
    • 2007
  • In this paper, the acoustic emission(AE) behaviors were investigated with single-and 2-spot resistance spot welded SPCC specimens. Test specimens were welded horizontally and/or vertically according to the rolling direction of base netal in 2-spot welding. In the case of 2-spot welding, when tensile-shear test has below amplitudes: crack initiation $50{\sim}60dB;$ tear fracture $40{\sim}50dB$. And when cross tensile test has below amplitudes: early stage $75{\sim}85dB;$ yielding point $65{\sim}75dB;$ post yielding $40{\sim}60dB;$ plug fracture $70{\sim}80dB\;or\;90{\sim}100dB$. Also, from the b-value that is slope of AE amplitude, we knew that there are lots of low amplitudes if b-value is big(i.e., tensile-shear $specimen{\rightarrow}tear$ fracture or shear fracture), and there are lots of high amplitudes if b-value is small(i.e.. cross tensile $specimen{\rightarrow}plug$ fracture). As the results of fiacture mechanism analyses through AE amplitude distributions, change of the b-value represented fracture patterns of materials. Correspondingly, low amplitude signals appeared in crack initiation, and high amplitude signals appeared in base metal fracture. We confirmed that these amplitude distributions represented the change or degradation of materials.

A 2 GHz 20 dBm IIP3 Low-Power CMOS LNA with Modified DS Linearization Technique

  • Rastegar, Habib;Lim, Jae-Hwan;Ryu, Jee-Youl
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.443-450
    • /
    • 2016
  • The linearization technique for low noise amplifier (LNA) has been implemented in standard $0.18-{\mu}m$ BiCMOS process. The MOS-BJT derivative superposition (MBDS) technique exploits a parallel LC tank in the emitter of bipolar transistor to reduce the second-order non-linear coefficient ($g_{m2}$) which limits the enhancement of linearity performance. Two feedback capacitances are used in parallel with the base-collector and gate-drain capacitances to adjust the phase of third-order non-linear coefficients of bipolar and MOS transistors to improve the linearity characteristics. The MBDS technique is also employed cascode configuration to further reduce the second-order nonlinear coefficient. The proposed LNA exhibits gain of 9.3 dB and noise figure (NF) of 2.3 dB at 2 GHz. The excellent IIP3 of 20 dBm and low-power power consumption of 5.14 mW at the power supply of 1 V are achieved. The input return loss ($S_{11}$) and output return loss ($S_{22}$) are kept below - 10 dB and -15 dB, respectively. The reverse isolation ($S_{12}$) is better than -50 dB.

Comparative analysis of running-type brassieres on the market (런닝형 브래지어의 비교분석)

  • Park, Do Yoon;Jung, Heh Soon;Na, Mi Hyang
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.5
    • /
    • pp.621-634
    • /
    • 2012
  • With comparative analysis of running-type brassieres on the market about suitability for middle-aged women, this study is to provide basic data of running-type brassieres' pattern which is highly suitable. In the pursuit of this purpose, this study carried out wearing experiment targeting 3 middle-aged women with normal body shape which is 85B of chest circumference. The result is as follows. The significant difference was recognized in the breast. The products were rated in order of C>A>B>D, E, F, G>H by the observers, and C>B>D>A>F>E=G>H by the subjects. The significant difference was recognized in the armhole area. The products were ranked in the order of C, D>B, G, E>A, F, H by the observes and D, C>B>G>F>A>H by the subjects. The significant difference was also recognized in 6 categories(14~19) for the torso. According to the overall average values, the products were rated in the order of B, C, D>A, D, F, G by the observers and B=D>C>H>F>G>A>E by the subjects. The overall evaluation exhibited the significant difference. The products were ranked in the order of D>C>E>B>H>A>G>F by both observers and subjects. Therefore it was confirmed that the product D was appropriate in general. To conclude of comparative analysis about 8 kinds of running-type brassieres on the market, the average values of the product C and D in all categories had high marks for each category. The product C was comfortable and capable of covering the breast well, however, a gap was formed in outside-up part. The product D, made from lacy fabric, was very comfortable and well-fitted but there was inconsistency between the mold-cup and the breast shape.

A Study of Compound Changes in Coffee Beans by Different Roasting Condition

  • Lee, Jae Chul
    • Culinary science and hospitality research
    • /
    • v.22 no.6
    • /
    • pp.114-119
    • /
    • 2016
  • This study aimed to investigate changes in the diverse compound in coffee beans under different roasting conditions. Four different kinds of chemical characteristics (phenolic contents, flavonoid contents, chlorogenic acid, and caffeine) were analyzed. According to the temperature of coffee roasting, this study categorized green bean, extract A ($191^{\circ}C$), B ($202^{\circ}C$), C ($220^{\circ}C$), and D ($233^{\circ}C$). As a result, total phenol compound showed low level of total phenol compound at lower temperatures. Extract A showed significantly higher level of total flavonoid ($111.33{\pm}10.14$), green bean showed $83.67{\pm}2.43$, Extract B $46.11{\pm}2.38$, C and D showed $31.44{\pm}0.12$, $19.22{\pm}0.46$ respectively. Green bean showed higher level of chlorogenic acid ($64.47{\pm}0.51$), Extract A ($39.66{\pm}0.47$), extract B ($12.45{\pm}0.99$), C, D ($3.59{\pm}0.31$, $0.63{\pm}0.12$) respectively. This study also noted that there are significant different in terms of caffeine content. Extract A has higher level of caffeine content ($38.45{\pm}1.70$) significantly, green bean ($27.14{\pm}2.27$), extract B ($18.95{\pm}0.64$), extract C ($17.89{\pm}0.96$). As a conclusion, we revealed that roasting conditions play an important role in the composition of coffee compounds.

Effect of Propolis on Healing of Full-thickness Skin Wound in Rabbits (Propolis가 토끼의 전층 피부 창상치유에 미치는 영향)

  • 정성일;강성수;조성구;정석화
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.62-69
    • /
    • 2000
  • The effects of vaselin, silver sulfadiazine and propolis on healing of full-thickness skin defects were evaluated in rabbits. Two wounds measuring 2{times}2cm$ were created bilaterally (4 wounds/rabbit) on the dorsolateral aspect of the trunk of 17 Ne Zealand white. Wound treatments were evenly distributed 4 sites, using a Latin square design. Treatments evaluated were: vaselin(group A), silver sulfadiazine(group B), 5% propolis (group C) and 10% propolis(group D). On days 3, 7 and 14, mean percentage of wound in group A, B, and C. On days 21 and 28, mean percentage of wound contraction in group D were significantly higher than those of groups B and C, but were not higher than that of group A. Microscopically fibersis and epithelialization were noticed on days 14 and 28 after wounding in all group. Rates of fibrosis of collagen fiber and epithelialization of groups C and D were exceeded those of groups A and B. All wounds in all group achieved 100% healing during the 28-day study period. Results indicate that use of propolis as would ointment on full-thickness skin wounds in rabbits increase rate of healing.

  • PDF

Design of Ultra Wide Band MMIC Digital Attenuator using Switched-T Attenuator (스위치드-티 감쇠기를 이용한 초광대역 MMIC 디지털 감쇠기 설계)

  • Ju, In-Kwon;Yom, In-Bok
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • A broadband DC to 40 GHz 5-bit MMIC digital attenuator has been developed. The ultra broadband attenuator has been achieved by newly inserted the transmission lines in conventional Switched-T attenuator and the optimization of the transmission line parameters. Momentum was employed in design for an accurate performance prediction at high frequencies and Monte Carlo analysis was applied to verify performance stability against the MMIC process variation. The attenuator has been fabricated with 0.15 $\mu$m GaAs pHEMT process. This attenuator has 1 dB resolution and 23 dB dynamic range. High attenuation accuracy has been achieved over all attenuation range and full 40 GHz bandwidth with the reference state insertion loss of less than 6 dB at 20 GHz. The input and output return losses of the attenuator are better than 14 dB over all attenuation states and frequencies.

  • PDF

The Characteristics of MMIC Phase Shifter with Lange Coupler (Lange 커플러를 이용한 MMIC 위상변위기 특성)

  • 정명득;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.104-110
    • /
    • 2003
  • This paper proposed a simple 180$^{\circ}$ MMIC phase shifter for wideband application. The phase shifter simply consists of a Lange coupler and two GaAs PIN diodes. The measured performance of the phase shifter in the 2 to 6 GHz band shows a maximum phase error of less than 13$^{\circ}$, maximum 3.2 dB insertion loss, and minimum 6.3 dB return loss.

A study on the Design of Gain Variable Low Noise amplifier using PCSNIM techniques for Zigbee System (Zigbee시스템에 적용 하기위해 PCSNIM 기법을 사용한 가변 이득 저잡음 증폭기 설계 연구)

  • Choi, Hyuk-Jae;Choi, Jin-Kyu;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.121-124
    • /
    • 2009
  • In this paper, the techniques and design focus of flexible gain coltrol of LAN(Low Noise Amplifier) using the TSMC 0.18um CMOS process. The design frequency set up a standard on 2.4GHz that is used in Zigbee system. The design concepts a basic Cascode LNA techniques and a swiching circuit consisted of 4 NMOS of load resistance, which convert the output impedenceby tuning on or off. The result show the gain change by NMOS operated swich. The simulation result is that Gain is 14.07dB-16.79dB and NF(Noise Figure) is 1.06dB-1.09dB.

  • PDF