• Title/Summary/Keyword: 13세기 2

Search Result 277, Processing Time 0.024 seconds

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

The Crystal Structure of $C_{13}H_{15}N_3O_3$ ($C_{13}H_{15}N_3O_3$의 결정 구조)

  • Park, Hai-Yoon;Kim, Moon-Jib;Park, Ho-Jong
    • Korean Journal of Crystallography
    • /
    • v.15 no.1
    • /
    • pp.24-28
    • /
    • 2004
  • The structure of $C_{12}H_{15}N_3O_3$ has been determined by X-ray diffraction methods. The crystal system is monoclinic, space group $P2_1/c$, unit cell constants, a = 12.9955(9) ${\AA}$, b = 7.7137(5) ${\AA}$, c = 13.4699(11) ${\AA}$, ${\beta}$ = 107.86(1)$^{\circ}$, V = 1285.2(1) ${\AA}^3$, T = 296 K, Z = 4, $D_c$ = 1.350 $Mgm^{-3}$. The intensity data were collected on an Enraf-Nonius CAD-4 Diffractometer with graphite monochromated Mo $K{\alpha}$ radiation (${\lambda}$ = 1.71073 ${\AA}$). The molecular structure was solved by direct methods and refined by full-matrix least squares to a final R = 4.19% for 1644 unique observed $F_0\;>\;4{\sigma}(F_0)$ reflections 193 parameters.

Si기판상의 BST박막 제조를 위한 MgO 완충층의 제조 및 특성

  • 최명률;이태일;박인철;김홍배
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.10-13
    • /
    • 2002
  • 본 논문에서는 P-type (100)Si 기판위에 RF magnetron sputtering법으로 강유전체 BST 박막을 증착하기 위한 완충층용(buffer layer) MgO 박막을 제작하였다. 증착 시 기판온도는 $400^{\circ}C$, 작업가스 Ar:$O_2$:=80:20, 작업진공 10m torr에서 RF 파워를 25W, 50W, 7SW로 변화하면서 증착하여 최적의 RF 파워조건을 확립하였다. XRD 측정결과 RF 파워 세기에 관계없이 MgO(200)피크만 관찰되었고 RF 파워 5OW에서 제작한 박막이 가장 양호한 결정성을 나타내었고 이 때 I-V측정결과 $\pm$ 1.5 MV/$cm^2$에서 $10^{-7}$A/$cm^2$이하의 양호한 누설전류특성을 나타내었고 C-V 측정결과 히스테리시스가 거의없는 양호한 인터페이스 특성을 보여주었고 비유전율은 약 8.4였다.

  • PDF

회원사탐방 - 직무능력 향상을 위한 경영컨설팅 성마기업(주)

  • 대한기계설비건설협회
    • 월간 기계설비
    • /
    • s.311
    • /
    • pp.52-60
    • /
    • 2016
  • 21세기에 기업의 운명을 결정짓는 것은 기업문화이다. 바람직한 기업문화는 훌륭한 일터를 만들기 위한 전제조건이다. 그런 까닭에 오늘날 대부분의 기업들이 각사 특성에 적합한 바람직한 기업문화 정착에 많은 관심을 기울이고 있다. 성마기업(주)이 그렇다. 성마기업은 투명경영을 통해 임직원 모두 주인의식으로 무장하고 있으며 소통하는 기업문화를 갖고 있다. 또 매년 전직원이 모여서 교육을 실시한다. 성마기업은 지난 1월 13일 오후 1시부터 15일 오후 6시까지 인천광역시 소재 건설기술교육원에서 60여명의 전 직원이 참석한 가운데 2박 3일간 직무능력 향상 교육을 실시했다. 이 교육에 예외란 없다. 본사를 비롯, 전국에 있는 현장의 모든 직원들이 참석하여 교육을 받는다. 2박 3일간 일정 중 교육시간은 약 20~24시간이며 1인당 30만원 정도(강사교, 교재, 숙식비 포함) 비용이 든다. 이 중 1인당 10만원 정도는 고용보험료로 환급받을 수 있다. 단, 교육 내용이 업무와 연관없는 과목은 환급에서 제외된다. 본지는 지난 2월호에 게재된 '2016년 성마기업 직무능력 향상 교육'에 이어 이번호에는 성마기업이 지난해 실시한 경영컨설팅의 주요 결과에 대해 게재한다.

  • PDF

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

Simultaneous Separation Analysis of Some Metal Ions in Piperidinedothiocarbamate Chelates by Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇가지 금속 이온들의 Piperidinedithiocarbamate 킬레이트 동시분리분석)

  • Lee, Won;Bahng, Seung-Hoon;Kim, Mi-Kyoung
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Simultaneous separation and analysis of Ni(II), Pd(II), Co(II), Cu(II) and Hg(II) in peperidinedithiocarbamate (PDTC) chelates were investigated by reversed phase liquid chromatography. The optimum conditions for the separation of PDTC metal chelates were examined with respect to the pH, extraction solvent, and mobile phase strength on Novapak $C_{18}$ column using methanol/water mixture as mobile phase. All metal PDTC chelates were eluted in an acceptable range of capacity factor value ($0{\leq}log\;k^{\prime}{\leq}1$). The linear calibration curves were obtained in the concentration range of $0{\sim}1.2{\mu}g/mL$ for five metal ions, and also good precision in the range of 1.96~3.41% RSD was obseved. Under the optimum conditions, trace metat ions in the composite water sample were successfully separated and determined with relative error of ${\pm}2.0%$.

  • PDF

PHOTOTAXIS OF FILEFISH, CONGER EEL AND CRUCIAN CARP (어류의 주광성에 관한 연구 -쥐치, 붕장어, 붕어-)

  • YANG Yong-Rhim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.1
    • /
    • pp.1-13
    • /
    • 1980
  • The purpose of the present study is to find the light intensity which induces maximum gathering rate and to observe the variation of the gathering rate both in daytime and at night by using three species of commercial fishes: filefish, Stephanolepis cirrhifer (Temminck et Schlegel), conger eel, Astroconger myriaster (Brevoort) and crucian carp, Carassius oarassius (Linnaeus). An experimental tank $(360L\times50W\times55Hcm)$ was set up in a dark room. An illumination system was attached to one end of the tank to control horizontal, light intensity. Six artificial light sources were prepared by combination of two light bulbs (5W, 150W) and seven filters. During the experiment water depth was maintained 50 cm level in the tank. The tank was marked into six longitudinal sections each being 60 cm long to observe the distribution of fish. The fish were acclimatized in dark condition for 40 minutes prior to the main experiment. Upon turning on the light, the number of fish .in each section was counted 40 times every 30 seconds, and the gathering rates were obtain from the average number of fish in each section. In filefish the light intensity inducing maximum gathering rate was 0.7 lx(0.5-1.1 lx), and there nab little difference between day and night. Gathering rate varied propotionally to the length of illumination time. In conger eel the light intensities inducing maximum gathering rate were 1.9 lx(1.2-2.9 lx) in daytime and 5.2 lx (3.2-7.7 lx) at night. Thus, there was a considerable difference between day and night, but the gathering rate remained almost unchanged regardless to the length of illumination time. In crucian carp gathering rate did not show a definite pattern hut fluctuated irregularly. The gathering rate, however, was slightly higher at 16.21 lx, and there was little difference between day and night.

  • PDF

Development of the IRIS Collimator for the Portable Radiation Detector and Its Performance Evaluation Using the MCNP Code (IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lee, Wanno;Choi, Sang-Do;Kim, Change-Jong;Kang, Mun Ja;Park, Sang Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or the rapid response to the nuclear accident, several collimators with the different inner radii should be prepared according to the level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. In this study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same method used in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layers with different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performance evaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of the collimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiation detector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incident photon to the detector without replacing the collimator.

Sterilization of Yakju(Rice Wine) on a Serial Multiple Electrode Pulsed Electric Field Treatment System (직렬배열 다중전극 고전압 펄스 전기장 처리장치를 이용한 약주의 살균)

  • Mok, Chull-Kyoon;Lee, Sang-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.356-362
    • /
    • 2000
  • Yakju(rice wine) was sterilized with high-voltage square-wave pulses of $1\;{\mu}s$ duration at various electric field strengths and frequencies on a serial multiple electrode pulsed electric field(PEF) treatment system consisted of 7 electrodes connected in series. The initial microbial counts of Yakju were $1.88{\times}10^3{\sim}2.13{\times}10^4$ CFU/mL for total aerobes, $1.55{\times}10^3{\sim}2.85{\times}10^4$ CFU/mL for lactic acid bacteria and $1.72{\times}10^3{\sim}2.39{\times}10^4$ CFU/mL for yeasts. The sterilization of microorganisms in Yakju was a first order reaction and the sterilization effect increased as the field strength and the frequency increased. The $D_{Hz}-value$ and the $D_{PEF}-value$ decreased with the electric field strength. Yeast showed lower $D_{PEF}-value$ than bacteria. Lactic acid bacteria showed lower $D_{PEF}-value$ than general aerobic bacteria under the electric field strength below 30 kV/cm, but higher ones under that above 40 kV/cm. The $Z_{PEF}-value$ of general aerobic bacteria, lactic acid bacteria and yeast in Yakju were 39.4, 49.3 and 47.6 kV/cm, respectively. The PEF sterilization resulted in less changes in color and sensory properties than heat sterilization, and the PEF treated Yakju showed superior quality to the heat treated one. The commercial sterilization of Yakju was accomplished with 2-cycle treatment on the tested serial PEF treatment system.

  • PDF

A Study on the Operation Mechanism of Celestial Movement Apparatus of ChoiYuJi's Armillary Sphere(渾天儀)

  • Ham, Seon Young;Kim, Sang Hyuk;Lee, Yong Sam
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.86.2-86.2
    • /
    • 2015
  • 17세기 최유지가 제작한 혼천의는 수격식 동력으로 움직이는 자동 천문시계이다. 이 혼천의는 수격식 동력장치와 시간을 알려주는 시보장치, 태양과 달의 운행을 나타내는 천체운행장치로 구성되어 있다. 이 연구는 최유지 혼천의의 천체운행장치의 작동 메카니즘에 대한 것이다. 최유지 혼천의의 천체운행장치는 태양의 연주운동과 일주운동을 재현하는 태양운행장치와 달의 공전운동과 위상변화를 재현하는 달운행장치로 구성되어 있다. 이 장치들은 조선 초기의 수격식 천문시계에 설치되었던 천체운행장치보다는 발전된 양상을 보인다. 조선 초기에 실로 매어서 운행하던 태양운행장치는 차전(叉箭)과 경각(梗角), 소축(小軸)이라는 장치들이 혼천의에 추가로 설치되어 실과 함께 태양장치를 운행하였다. 또한 조선 초기에는 설치되지 않았던 달운행장치가 새롭게 설치되어 방각(方角), 차전(叉箭), 백각환에 13도 간격으로 박힌 대나무못과 실을 활용하여 달장치를 운행하게 하였다. 우리는 최유지 혼천의의 천체 운행장치 작동 메카니즘에 대하여 분석하고 개념모델을 제시했다.

  • PDF