• Title/Summary/Keyword: 128 channels cardiac activation

Search Result 4, Processing Time 0.016 seconds

The Design of 128 Channels Cardiac-Activation Pre-Amplifier (128 채널 심장전기도 전치 증폭기의 설계)

  • Yoo, Sun-Kook;Chang, Byung-Chul;Jung, Dong-Il;Han, Young-Oh
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.550-556
    • /
    • 2001
  • The computerized cardiac analysis system, which acquires and analyzes the electrical activation signal propagating along the surface of the heart, is indispensible equipment for the open heart surgery and electrical cardiac study. In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and isolation part. It has distinct features; high voltage protection, leakage current limitation, isolation and the maximization of common mode rejection ratio with respect to the half-cell potential difference due to different electrode materials. The final pre-amplifier circuit is assembled with 8 boards, each of which composing of 16 channels.

  • PDF

The imaging of 128 channels cardiac activation signal (128채널 심장전기도 신호의 영상화)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.133-137
    • /
    • 2010
  • In this study, The imaging of 128 channels cardiac activation signal is implemented. It is performed within one minutes and very useful in open-heart operation with analysis in a short time. Especially the keeping of data and the moving of system is facility because it was implemented with being based on PC. The cardiologist can call data and analysis them anytime after a surgery.

The design of filters for multi-channel cardiac activation main amplifier (다중 채널 심장전기도 주 증폭기를 위한 필터 설계)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.180-184
    • /
    • 2010
  • In this paper, the filter design and simulation are performed to construct the multi-channel cardiac activation main amplifier. The main amplifier consists of sample and holder, variable high pass filter, notch filter, variable low pass filter. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution and the filter is designed for 128 channels cardiac activation main amplifier.

The design of amplifier for 128 channels Cardiac-activation system (128채널 심장전기도 시스템의 증폭기 설계)

  • Han, Young-Oh
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.123-130
    • /
    • 2007
  • In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and main-amplifier with notch filter part.

  • PDF