• Title/Summary/Keyword: 125kHz

Search Result 118, Processing Time 0.026 seconds

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

Design of power amplifier and antenna for wireless power transmission in 125kHz (125kHz대에서 무선전력전송을 위한 전력증폭기와 송수신 Antenna 설계)

  • Im, Sang-Uk;Kim, Yong-Sang;Kim, Do-Hun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.27-30
    • /
    • 2003
  • Wireless power transmission system is one of the very interesting field not only in a technical and economical point of view but also that people are still trying to realize lossless power transmission. This paper has a purpose on the efficient power transmission at the passive type ICcard by using wireless power transmission system. The most difficult but important part of the passive type RF-ID system is building the system that supplies power from Reader-antenna to IDcard-antenna. To check what is the most efficient way to deliver power depending on what kind of specifications of the power-amp in reader, antenna and antenna in IDcard is for operating IDcard circuit efficiently receiving the power from reader-antenna. For this, we used 125kHz sinewave for RF signal as a basic specification, power-amp : OP-Amp for amplifying signal and AB Class push-pull power-amp for amplifying power, loop type antenna.

  • PDF

Design and Analysis for 125kHz RFID system (125kHz RFID 시스템의 회로 설계 및 분석)

  • Jin, In-Su;Yang, Kyeong-Rok;Ryu, Hyeong-Sun;Kim, Hyun;Hong, Il-Hee;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3133-3135
    • /
    • 2000
  • RFID (Radio Frequency Identification) system is applied to identify, locate and track people, cars, animals. Passive RFID system consists of reader and tag. The reader transmits a carrier signal, receives the backscattering signal, performs data processing. The tag is energized by carrier signal that is transmitted from the reader and the information stored in the tag is transmitted back to the reader. In this paper, the design and analysis of the 125kHz RFID system is presented and is confirmed through experiment.

  • PDF

Comparison of SE Evaluation Methods for HEMP Shelters (HEMP 방호시설의 SE 평가방법의 비교)

  • Chung, Yeon-Choon;Lee, Jongkyung;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1197-1200
    • /
    • 2014
  • Two test standards to be applied for evaluating shielding effectiveness of HEMP protection facilities, MIL-STD-188-125-1 and IEEE std. 299, provide different test results in spite of the same facility. In particular, at the frequency range of 10 kHz~20 MHz, it is confirmed that the test results by the IEEE Std. 299 are about 20~30 dB lower than the evaluated results by MIL-STD-188-125-1. These results are due to the different measurement conditions specified in the two test standards. Therefore, IEEE Std. 299 can be applied for the shortening of test distance, but the required SE performance based on MIL-STD-188-125-1 must be modified.

Current perception threshold in diabetic sensory polyneuropathy with normal routine nerve conduction study

  • Park, Kyung Seok;Kwon, Yong Chul;Youn, Minjung;Park, Yong-Shik;Hong, Yoon-Ho;Sung, Jung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.125-130
    • /
    • 2017
  • Background: Routine nerve conduction study (NCS) can only be used to evaluate the function of large fibers, and the results of NCS are often normal in patients with distal sensory polyneuropathy. The measurement of the current perception threshold (CPT) has been reported to represent a variety of peripheral nerve fiber functions. This study was performed to investigate the value of measuring CPT in patients with diabetic sensory polyneuropathy who have no abnormalities in routine NCS. Methods: Twenty-seven diabetic patients with sensory polyneuropathy and normal routine NCS and 18 age-matched control subjects participated in this study. The CPT was measured on the unilateral index finger and great toe of each subject at frequencies of 5 Hz, 250 Hz, and 2,000 Hz. Results: CPT values were significantly higher in the patient group than in the control group, especially with stimuli at the lowest frequency of 5 Hz (p < 0.05). There were significant correlations between the CPT values obtained at three different frequencies in the patient group, whereas the correlation was only significant in the pair of 250 Hz/5 Hz (both in the hands and feet), and in the pair of 2,000 Hz/250 Hz (in the feet) for the control group. Conclusions: Our data suggest that the CPT test, especially at a stimuli frequency of 5 Hz, may be a useful screening tool for diabetic polyneuropathy in patients who show no abnormalities in routine NCS.

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF

Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor (홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구)

  • Cho, Hyun-Sung;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.178-182
    • /
    • 2012
  • This research suggested that the extraction of respiratory rate could be made possible by using frequency analysis in the data process for clip-type pulsimeter equipped with permanent magnet and Hall sensor. The pulse analysis included of cardiac motion information depending on variation of pulse waveforms is investigated by means of Fast Fourier Transformation (FFT). The peaks of FFT spectrums measured at 15, 20, 30, 40, and 50 tempos are coincided to each respiratory rate having 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, and 0.41 Hz, respectively. The FFT spectrum using algorithm for the extraction of respiratory rate showed the best pulse waves measured during 300 s. Based upon these results, the clip-type pulsimeter could extract the effective respiratory rate reflecting physical effects.

Analysis of Bioimpedance Change and the Characteristics of Blood Pressure according to Posture (자세에 따른 생체임피던스 변화와 혈압 특성 분석)

  • Cho, Young Chang;Kim, Min Soo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.5
    • /
    • pp.25-31
    • /
    • 2014
  • Bioelectrical Impedance Analysis(BIA) is a widely used method for estimating body composition changes which is a non-invasive, inexpensive, safety and reproductive method. We studied the bioimpedance change and the distinction of blood pressure according to body posture and conducted three kinds of experiments: the real-time bioimpedance measurement, the simulation using equivalent circuit model and the blood pressure measurement. Bioimpedance is measured during 4 minutes at the multi-frequency(1 kHz, 10 kHz, 20 kHz, 50 kHz, 70 kHz, 100 kHz). From the experiment results, the changes in body postures result in changes of resistance and reactance, with an average rapid increase of body impedance when going from standing, sitting to supine. Specially, the laying resistance on average was 16.49% higher than supine resistance at 50 kHz and the laying reactance measurement was also 26.05% higher than sitting reactance at 1 kHz. Blood pressure in standing posture was higher than those in other postures both in maximum($125.14{\pm}12.30$) and in minimum($75.57{\pm}10.31$). The results of BIA and blood pressure in this study will be contributed to the research on acute illness, extreme fat, and body shape abnormalities.

A Study on the Frequency Synthesizer for Wireless Microphone Transmitter (무선 마이크 송신기용 주파수 합성기에 판한 연구)

  • 서상원;곽무성;조경준;김종헌;이종철
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.206-210
    • /
    • 2000
  • 본 논문에서는 PLL 주파수 합성기를 이용한 900 MHz 대역의 무선 마이크용 송신기를 설계 및 제작하였다. 위상잡음을 고려한 주파수 합성기는 VCO, Loop Filter 및 RF 중폭부로 구성한 후 HP EEsof ADS ver. 1.3을 이용하여 설계하였다. VCO는 구조가 간단하며 변조가 용이한 직접변조방식을 사용하였으며 Loop Filter는 주파수 합성기의 기준 고조파 성분을 낮추기 위해 수동 3차 필터를 사용하였다. 주파수 대역 928.125 MHz~929.875 MHz 내에서 채널간격 125 kHz를 갖으며 15개의 채널이 되도록 분주비를 설정한 주파수 합성기는 제작 결과, 송신기 출력 9.3 dBm과 위상잡음이 100 kHz에서 -113 dBc/Hz 이하의 위상잡음 특성을 나타내었고 불요주파수 특성은 -80 dBc 이하의 특성을 나타내었다.

  • PDF

A Study of Sound Pressure Characteristics of Error Sensors by Position in Active Noise Barrier Development (능동형 방음벽 개발을 위한 에러센서 위치 연구)

  • Cha, Sang-Gon;Kim, Dong-Hwan;Troshinun, Andrey;Choi, Jang-Cheol;Shin, Eun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1756-1757
    • /
    • 2011
  • 본 논문에서는 FXLMS 알고리즘을 이용하여 3차원 폐공간(반무향실)에서의 순음(125Hz)을 이용하여 부 음원과 에러센서의 위치 변화에 따른 소음저감 정도를 분석하였으며, 이 결과를 바탕으로 능동형 방음벽의 구현의 기초자료로 활용하고자 하였다. 부음원(제어스피커, 이하 부음원)과 에러센서간 거리차는 0.5m, 1.5m, 2.5m를 대상으로 실험을 실시하였으며 그 중 거리차가 1.5m 지점의 경우, 125Hz부근에서는 최대 18.3dB, Overall(80Hz~200Hz)값은 18.2dB(A)의 소음저감 효과가 있는 것으로 나타나, 가장 효과적인 부음원과 에러센서간의 거리차인 것으로 평가되었다.

  • PDF