• 제목/요약/키워드: 1-g model test

검색결과 557건 처리시간 0.03초

Prediction of dynamic behavior of full-scale slope based on the reduced scale 1 g shaking table test

  • Jin, Yong;Kim, Daehyeon;Jeong, Sugeun;Park, Kyungho
    • Geomechanics and Engineering
    • /
    • 제31권4호
    • /
    • pp.423-437
    • /
    • 2022
  • The objective of the study is to evaluate the feasibility of the dynamic behavior of slope through both 1 g shaking table test and numerical analysis. Accelerometers were installed in the slope model with different types of seismic waves. The numerical analysis (ABAQUS and DEEPSOIL) was used to simulate 1 g shaking table test at infinite boundary. Similar Acceleration-time history, Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) were obtained, which verified the feasibility of modeling using ABAQUS and DEEPSOIL under the same size. The influence of the size (1, 2, 5, 10 and 20 times larger than that used in the 1 g shaking table test) of the model used in the numerical analysis were extensively investigated. According to the similitude law, ABAQUS was used to analyze the dynamic behavior of large-scale slope model. The 5% Damping Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) at the same proportional positions were compared. Based on the comparison of numerical analyses and 1 g shaking table tests, it was found that the 1 g shaking table test result can be utilized to predict the dynamic behavior of the real scale slope through numerical analysis.

진동대 실험을 통한 흙막이 벽체의 변위 거동 특성 (Displacements Behavior of Retaining Walls by Shaking Table Test)

  • 윤원섭;윤부열;양철규;박연준
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.409-418
    • /
    • 2018
  • In this study, experiments were carried out after fabricating and installing a physical model considering the size of the prototype. In the model test, the number of struts placed on the wall and the applied acceleration were selected as test variables. Two different types of waves, long-period and short-period, were applied with magnitudes of 0.05g, 0.1g, 0.2g, and 0.3g. Measured are displacements at specified points. As a result of the analysis, displacement exceeding the allowable displacement of the wall occurred at an acceleration greater than 0.05g to 0.1g depending on the seismic waves applied. Therefore guidelines have to be established through further studies for aseismic design of earth retaining walls.

Size-effect of fracture parameters for crack propagation in concrete: a comparative study

  • Kumar, Shailendra;Barai, S.V.
    • Computers and Concrete
    • /
    • 제9권1호
    • /
    • pp.1-19
    • /
    • 2012
  • The size-effect study of various fracture parameters obtained from two parameter fracture model, effective crack model, double-K fracture model and double-G fracture model is presented in the paper. Fictitious crack model (FCM) for three-point bend test geometry for cracked concrete beam of laboratory size range 100-400 mm is developed and the different fracture parameters from size effect model, effective crack model, double-K fracture model and double-G fracture model are evaluated using the input data obtained from FCM. In addition, the fracture parameters of two parameter fracture model are obtained using the mathematical coefficients available in literature. From the study it is concluded that the fracture parameters obtained from various nonlinear fracture models including the double-K and double-G fracture models are influenced by the specimen size. These fracture parameters maintain some definite interrelationship depending upon the specimen size and relative size of initial notch length.

지반-말뚝 동적 상호 작용 평가를 위한 1g 진동대 실험의 수치 모델링 (Numerical Modeling of 1g Shaking Table Model Pile Tests for Evaluating Dynamic Soil-Pile Interaction)

  • 오만교;김성환;한진태;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.173-183
    • /
    • 2010
  • Numerical analysis using a three dimensional finite element program(ABAQUS) is a powerful method which can evaluate the soil-pile-structure interaction under the dynamic loading and reduce the computation time significantly, but has not be widely used because modeling a soil-pile system and setting the parameter for the entire model are difficult and a three dimensional finite element program is not user friendly. However, a three dimensional finite element program is expected to be widely used because of advance in research of modeling technique and development of the modeling and visualization. In this study, ABAQUS is used to simulate the 1g shaking table model pile test, and the numerical results are compared with the 1g shaking table test results. The application about the soil stiffness and boundary condition change is estimated and then parametric study for various input acceleration amplitudes, various input frequencies, and various surcharge is carried out.

  • PDF

Numerical simulation of shaking table test on concrete gravity dam using plastic damage model

  • Phansri, B.;Charoenwongmit, S.;Warnitchai, P.;Shin, D.H.;Park, K.H.
    • Structural Engineering and Mechanics
    • /
    • 제36권4호
    • /
    • pp.481-497
    • /
    • 2010
  • The shaking table tests were conducted on two small-scale models (Model 1 and Model 2) to examine the earthquake-induced damage of a concrete gravity dam, which has been planned for the construction with the recommendation of the peak ground acceleration of the maximum credible earthquake of 0.42 g. This study deals with the numerical simulation of shaking table tests for two smallscale dam models. The plastic damage constitutive model is used to simulate the crack/damage behavior of the bentonite-concrete mixture material. The numerical results of the maximum failure acceleration and the crack/damage propagation are compared with experimental results. Numerical results of Model 1 showed similar crack/damage propagation pattern with experimental results, while for Model 2 the similar pattern was obtained by considering the modulus of elasticity of the first and second natural frequencies. The crack/damage initiated at the changing point in the downstream side and then propagated toward the upstream side. Crack/damage accumulation occurred in the neck area at acceleration amplitudes of around 0.55 g~0.60 g and 0.65 g~0.675 g for Model 1 and Model 2, respectively.

Transform Coding Based on Source Filter Model in the MDCT Domain

  • Sung, Jongmo;Ko, Yun-Ho
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.542-545
    • /
    • 2013
  • State-of-the-art voice codecs have been developed to extend the input bandwidth to enhance quality while maintaining interoperability with a legacy codec. Most of them employ a modified discrete cosine transform (MDCT) for coding their extended band. We propose a source filter model-based coding algorithm of MDCT spectral coefficients, apply it to the ITU-T G.711.1 super wideband (SWB) extension codec, and subjectively test it to validate the model. A subjective test shows a better quality over the standardized SWB codec.

조적채움벽이 있는 1/5 축소 3층 비연성 철근콘크리트 골조의 진동대 실험 (Shaking Table Test of a 1/5 Scale 3-Story Nonductile infilled Reinforced Concrete Frame)

  • 이한선;우성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.541-546
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA`s) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period of the model.

  • PDF

Strength model for square concrete columns confined by external CFRP sheets

  • Benzaid, Riad;Mesbah, Habib Abdelhak
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.111-135
    • /
    • 2013
  • An experimental study has been carried out on square plain concrete (PC) and reinforced concrete (RC) columns strengthened with carbon fiber-reinforced polymer (CFRP) sheets. A total of 78 specimens were loaded to failure in axial compression and investigated in both axial and transverse directions. Slenderness of the columns, number of wrap layers and concrete strength were the test parameters. Compressive stress, axial and hoop strains were recorded to evaluate the stress-strain relationship, ultimate strength and ductility of the specimens. Results clearly demonstrate that composite wrapping can enhance the structural performance of square columns in terms of both maximum strength and ductility. On the basis of the effective lateral confining pressure of composite jacket and the effective FRP strain coefficient, new peak stress equations were proposed to predict the axial strength and corresponding strain of FRP-confined square concrete columns. This model incorporates the effect of the effective circumferential FRP failure strain and the effect of the effective lateral confining pressure. The results show that the predictions of the model agree well with the test data.

상사법칙 검증을 위한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests for Similitude Laws)

  • 김성렬;황재익;김명모
    • 한국지반공학회논문집
    • /
    • 제22권5호
    • /
    • pp.59-67
    • /
    • 2006
  • 동일한 흙으로 조성된 모형지반에 대하여 1-g 모형실험과 원심모형실험을 수행하고 그 결과를 비교하였다. 원형지반은 10m 두께의 수평하고 느슨한 포화 사질토 지반으로 가정하였다. 1-g 모형실험은 1/20 축소모형, 원심모형실험은 1/40 축소모형을 이용하였다. 원심모형실험의 경우 점성유체를 사용하여 동적시간에 대한 상사비와 과잉간극수압소산시간에 대한 상사비가 동일하도록 하였다. 원심모형실험의 계측결과는 원형지반의 거동으로 가정하였다. 그리고, 1-g모형실험에 정상상태개념 및 두 가지 시간상사비 등을 적용하여 원형지반의 거동을 모사하고자 하였다. 동일한 위치에서의 과잉간극수압, 지반가속도 그리고 지표 침하량 등을 계측하여 비교하였다. 실험결과 지반의 투수계수가 작아서 진동 중 과잉간극수압 소산의 영향이 작고, 소산시간상사비를 적절하게 결정하면 1-g 모형실험으로부터 원형지반의 과잉간극수압 거동을 모사할 수 있는 것으로 나타났다.

Earthquake Simulation Tests of a 1 :5 Scale 3-Story Masonry-Infilled Reinforced Concrete Frame

  • Lee, Han-Seon;Woo, Sung-Woo;Heo, Yun-Sup
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.153-164
    • /
    • 1999
  • The objective of this research is to observe the actual response of a low-rise nonseismic moment-resisting masonry-infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. The reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N2IE component earthquake ground motion, whose peak ground acceleration(PGA) was modified to 0.12g, 0.2g, 0.3g, and 0.4g. The g1oba1 behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of the structure were measured. Before and after each earthquake simulation test, free vibration tests and white noise tests were performed to find the changes in the natural period of the model. When the results of the masonry-infilled frame are compared with those of the bare frame, it can be recognized that masonry infills contribute to the large increase in the stiffness and strength of the g1oba1 structure whereas it also accompanies the increase of earthquake inertia forces. However, it is judged that masonry infills may be beneficial to the performance of the structure since the rate of increase in strength appears to be greater than that of the induced earthquake inertia forces.

  • PDF