• Title/Summary/Keyword: 1-Dimensional

Search Result 12,194, Processing Time 0.037 seconds

The Seventeen Plane Groups (Two-dimensional Space Groups)

  • Kim Jin-Gyu;Kim Youn-Joong;Kim Young-Sang;Ko Jaejung;Kang Sang Ook;Han Won-Sik;Suh Il-Hwan
    • Korean Journal of Crystallography
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2005
  • Six basic symmetries and five Bravais lattices existing in the two-dimensional lattice are derived and then ten two-dimensional point groups are classified by each of five Bravais lattices. Finally seventeen two-dimensional space groups belonging to the ten point groups are studied.

Evaluation of Fabric Pilling Using Hybrid Imaging Methods

  • Kim Sung-Min;Park Chang-Kyu
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.57-61
    • /
    • 2006
  • A study has been made on the quantification and evaluation of fabric pilling using two-dimensional and three-dimensional hybrid imaging methods. Two-dimensional imaging method was good for some samples while three-dimensional measurement method for others, according to the properties of their base fabric. Various image processing techniques as well as three-dimensional data processing algorithms were applied for the extraction of pills from measured data and a series of shape parameters have been defined for the objective evaluation of fabric pilling. An evaluation criterion that is compatible with the conventional evaluation method has been proposed by applying the new evaluation method to the current photographic standards.

The accuracy of the depth perception of 3-dimensional images (이안식 입체영상에서 심도지각의 정확성에 관한 연구)

  • Cho, Am
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.19-31
    • /
    • 1994
  • The accurate error size and discrimination region in the perception of depth amount from 3- dimensional images by the human visual system will be the basic data for the utilization and application of the binocular 3 - Dimensional image system. This paper is focused on studying the accuracy of the depth amount perceived from 3-dimensional images by the human visual system. From the performed experiment, the following results have been obtained: (1) The depth amount perceived from the binocular 3-dimensional images has been displayed by a proper scale of distance, and found to be imprecise and also have a large variance. (2) In utilizing the binocular 3-dimensional image system, it seems more appropriate to make the images viewed outward rather than inward from the screen in the regard of error and variance. (3) The binocular 3- dimensional image system can be effectively applied to displaying unreal space, for example, the layout of room in design, from the viewpoint of perception characteristics of depth amount.

  • PDF

A Method for Constructing 3-Dimensional C-obstacles Using Free Arc (프리아크를 이용한3차원 형상 공간 장애물 구성 방법)

  • 이석원;임충혁
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.11
    • /
    • pp.970-975
    • /
    • 2002
  • We suggests an effective method to construct time-varying C-obstacles in the 3-dimensional configuration space (C-space) using free arc. The concept of free arc was defined mathematically and the procedure to find free arc in the case off-dimensional C-space was derived in [1]. We showed that time-varying C-obstacles can be constructed efficiently using this concept, and presented simulation results for two SCARA robot manipulators to verify the efficacy of the proposed approach. In this paper, extensions of this approach to the 3-dimensional C-space is introduced since nearly all industrial manipulators are reasonably treated ill the too or three dimensional C-space f3r collision avoidance problem The free arc concept is summarized briefly and the method to find lice arc in the 3-dimensional f-space is explained. To show that this approach enables us to solve a practical collision avoidance problem simulation results f3r two PUMA robot manipulators are presented.

3-Dimensional and Kinematic Analysis of a System for NDE(Nondestructive Examination) (비파괴 검사 응용을 위한 기구부의 3차원 기구학적 해석)

  • Kim, Hyung-Kuk;Lee, Dong-Hwal;Ahn, Hee-Tae;Park, Jae-Whe;Lee, Man-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2199-2201
    • /
    • 2001
  • The 3-dimensional measuring machine by using an ultrasonic sensor is used one of the NDE(Nondestructive Examination). It is applied to the inspection of pipelines, boreholes, pressure vessel and tank, and so on. In particular when a harsh environment prohibits the use of moving mechanical parts. The 3-dimensional measuring machine by using an ultrasonic sensor, which measure 1-dimensional information and 2-dimensional information simultaneously from a target of inspection, and then reembody 3-dimensional information. So we can find the situation in progress and predict remaining life and corrosion without destructive examination. It's a point of excellence that the 3-dimensional measuring machine is portable.

  • PDF

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

Application of 3D Simulation Surgery to Orbital Wall Fracture : A preliminary Case Study

  • Choi, Jong-Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.16-18
    • /
    • 2014
  • The orbit has a very special anatomical structure. The complex anatomical structure should be restored when we encounter the patient with orbital wall fracture. Unless these specific anatomy were reconstructed well, the patient should suffer from various complications such enophthalmos, diplopia or orbital deformity. In addition, because the patient has a his own specific orbital shape, individualized approach will be necessary. The aim of this trial is to try to restore the original orbit anatomy as possible based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. In order to restore the missing skipped images between the cuts of CT data because of the thinness of the orbital walls, we manipulated the DICOM data for imaging the original orbital contour using the preoperatively manufactured mirror-image of the RP model. And we fabricated Titanium-Medpor to reconstruct three-dimensional orbital structure intraoperatively. This prefabricated Titanium-Medpor was then inserted onto the defected orbital wall and fixed. Three dimensional approach based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Development of Centrifugal Compressors in an 1.2MW Industrial Gas Turbine(I)-Aerodynamic Design and Analysis- (1.2MW급 산업용 가스터빈 원심압축기 개발(1)- 공력설계해석 -)

  • Jo, Gyu-Sik;Lee, Heon-Seok;Son, Jeong-Rak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2707-2720
    • /
    • 1996
  • The aerodynamic design of the two-stages of centrifugal compressors in an 1.2MW industrial gas turbine is completed with the application of numerical analyses. The final shape of an intake, the axial guide vanes and a return channel is determined using several interactions between design and two-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional design and prediction of aerodynamic performances for the compressors are performed by two different methods; one is a method with conventional loss models, and the other a method with the two-zone model. The combination methods of the Betzier curves generate three-dimensional geometric shapes of impeller blades which are to be checked with a careful change of aerodynamic blade loadings. The impeller design is finally completed by the applications of three-dimensional compressible turbulent flow solvers, and the effect of minor change of design of the second-stage channel diffuser is also studied. All the aerodynamic design results are soon to the verified by component performance tests of prototype centrifugal compressors.