• Title/Summary/Keyword: 1-Axis and 3-Axis Accelerometer

Search Result 45, Processing Time 0.023 seconds

Posture guidance system using 3-axis accelerometer for scoliosis patient (3축 가속도 센서를 활용한 척추 측만증 환자용 자세 교정 유도 장치)

  • An, Y.S.;Kim, K.S.;Song, C.G.
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.396-398
    • /
    • 2009
  • Scoliosis is a three-dimensional deformity caused by lateral curvature of the spine. The existing braces used to correct the posture were some drawbacks such as inconvenience, tightness as well as unfitness to wear. In this study, we devised a posture guidance system in order to monitor a posture continuously and lead to pose correctly and a new method fur measuring a Cobb's angle value in third dimension based on two 3-axis accelerometers. As a result, the correlation coefficients between desired and measured angles were and standard error between desired and measured angles were 0.99, 1.32(x-axis), 0.99 and 1.10(y-axis), respectively. The devised system showed good potential for the optimal posture guide and an early detection of scoliosis.

  • PDF

Human Activity Recognition using an Image Sensor and a 3-axis Accelerometer Sensor (이미지 센서와 3축 가속도 센서를 이용한 인간 행동 인식)

  • Nam, Yun-Young;Choi, Yoo-Joo;Cho, We-Duke
    • Journal of Internet Computing and Services
    • /
    • v.11 no.1
    • /
    • pp.129-141
    • /
    • 2010
  • In this paper, we present a wearable intelligent device based on multi-sensor for monitoring human activity. In order to recognize multiple activities, we developed activity recognition algorithms utilizing an image sensor and a 3-axis accelerometer sensor. We proposed a grid?based optical flow method and used a SVM classifier to analyze data acquired from multi-sensor. We used the direction and the magnitude of motion vectors extracted from the image sensor. We computed the correlation between axes and the magnitude of the FFT with data extracted from the 3-axis accelerometer sensor. In the experimental results, we showed that the accuracy of activity recognition based on the only image sensor, the only 3-axis accelerometer sensor, and the proposed multi-sensor method was 55.57%, 89.97%, and 89.97% respectively.

Design of a 6-Axis Inertial Sensor IC for Accurate Location and Position Recognition of M2M/IoT Devices (M2M / IoT 디바이스의 정밀 위치와 자세 인식을 위한 6축 관성 센서 IC 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.1
    • /
    • pp.82-89
    • /
    • 2014
  • Recently, inertial sensors are popularly used for the location and position recognition of small devices for M2M/IoT. In this paper, we designed low power, low noise, small sized 6-axis inertial sensor IC for mobile applications, which uses a 3-axis piezo-electric gyroscope sensor and a 3-axis piezo-resistive accelerometer sensor. Proposed IC is composed of 3-axis gyroscope readout circuit, two gyroscope sensor driving circuits, 3-axis accelerometer readout circuit, 16bit sigma-delta ADC, digital filter and control circuit and memory. TSMC $0.18{\mu}m$ mixed signal CMOS process was used. Proposed IC reduces 27% of the current consumption of LSM330.

Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer (초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구)

  • 송치문;장한기;김승한;채장범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

Analysis on a Hip Joint System of New RGO Using Accelerometers (가속도계를 이용한 왕복보행보조기의 고관절 시스템 해석 -인체 진동해석과 FEM 해석을 중심으로-)

  • 김명회;장대진;장영재;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.882-887
    • /
    • 2003
  • This paper presented a design and control of a new RGO(reciprocating gait orthosis)and its simulation. The new RGO was distinguished from the other one by which had a very light-weight and a new RGO(reciprocating gait orthosis) system. The vibration evaluation of the hip joint system on the new RGO(reciprocating gait orthosis)was used to access by the 3-axis accelerometer with a low frequency vibration of less than 30 ㎐. The gait of the new RGO depended on the constrains of mechanical kinematics and the initial posture. The stability of dynamic walking was investigated by analyzing the ZMP (zero moment point) of the new RGO. It was designed according to the human wear type and was able to accomodate itself to the environments of S.C.I. Patients. The joints of each leg were adopted with a good kinematic characteristics. To analyse joint kinematic properties, we made the hip joint system of FEM and the hip joint system by 1-axis and 3-axis Accelerometers.

  • PDF

Image Deblurring Using Vibration Information From 3-axis Accelerometer (3축 가속도 센서의 흔들림 정보를 이용한 영상의 Deblurring)

  • Park, Sang-Yong;Park, Eun-Soo;Kim, Hak-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.1-11
    • /
    • 2008
  • This paper proposes a real-time method using a 3-axis accelerometer to enhance blurred images taken from a camera loaded in mobile devices. Blurring phenomenon is a smoothing effect occurring in photo images. Algorithms to cope with blurring phenomenon is essential since small-size mobile devices tremble severely by even a tiny hand-shaking of a user. In this paper, accurate sensing characteristics of the 3-axis accelerometer is acquired by applying the sensor in pendulum motion and the blurring phenomenon is modeled as a uniform distribution and Gaussian distribution. Also, non-Gaussian distributed model is observed in the experiment of real blurring phenomenon and a particular deblurring function is designed by reversing the model. It has been demonstrated that the application of trembling information to the deblurring function adequately removes the blurring phenomenon.

The Effect of Balance Control and Vestibular Function by an Aquatic Rotation Control and the Obstacle Avoidance Underwater with Hemiplegia Patients (수중에서 회전조절과 장애물 훈련이 편마비 환자의 전정기능과 균형조절에 미치는 영향)

  • Kwon, Hye-Min;Kim, Su-Hyun;Kim, Hyun-Jin;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • Purpose : The objective of this study is to effect of an aquatic rotation control and obstacle avoidance when conducted underwater on hemiplegia patient's balance ability and vestibular function. Methods : Twelve hemiplegia patients participated and were randomly assigned to a control group(I) with standard physical therapy and an aquatic group(II) with an aquatic rotation control, obstacle avoidance and standard physical therapy as well. The aquatic group trained using a Halliwick rotation control and obstacle avoidance through 3 times per week over 6 weeks. For all subjects, vestibular function, their balance, the change of electrooculogram (EOG), the change of accelerometer axis and torsiometer according to visual sense, vestibular sense with galvanic vestibular stimulation (GVS) or not during leg close stance were measured. Results : The EOG in the vertical and horizontal (p<0.05) were both significantly lowered. The change was significantly lower in the trajectory range of motion of trunk and spine with torsiometer when leg close stand (p<0.01) and leg close stand with GVS (p<0.01). The centre of gravity accelerated, there were reduced significantly difference X and Y axis of accelerometer during the closing of the leg without vision (p<0.05). There were reduced significantly difference X and Z axis of accelerometer during the closing of the leg with GVS (p<0.05). There were reduced significantly difference X and Z axis of accelerometer during the closing of the leg and close eyes with GVS (p<0.05). Conclusion : The balance ability, vestibular system and postural control is improved.

Wrist joint analysis of Myoelectronic Hand using Accelerometer (가속도계를 이용한 전동의수의 손목관절 시스템 해석)

  • 장대진;김명회;양현석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.876-881
    • /
    • 2003
  • This study focused on to design and toanalysis of a myoelectronic hand. We considered a low frequency factor in human life and to quantify low frequency which a human body responded to using a 1-axis ant a 3-axis accelerometer. The dynamic myoelectronic hand are important for tasks such a continuous prosthetic control and a EMG signal recognition, which have not been successfully mastered by the most neural approached To control myoelectronic hand, classifying myoelectronic patterns are also important. Experimental results of FEM are 110㎫ on Thumb, 200㎫ on Index finger, 220㎫ on Middle finger 260㎫ on Ring finger and 270㎫ on Little finger. Experimental results of accelerometer are 1.4-0.4(m/s2) ,(5-20(〔Hz〕) in Feeding activity and 0.4-0(m/s2) (0-10〔Hz〕) in Lifting activity. Considering these facts, we suggest a new type myoelectronic hand.

  • PDF

Emergency Detection System using PDA based on Self-response Algorithm

  • Jeon, Ah-Young;Park, Jun-Mo;Jeon, Gye-Rok;Ye, Soo-Young;Kim, Jae-Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.293-298
    • /
    • 2007
  • The aged are faced with increasing risk for falls. The aged have more fragile bones than others. When falls occur, it is important to detect this emergency state because such events often lead to more serious illness or even death. A implementation of PDA system, for detection of emergency situation, was developed using 3-axis accelerometer in this paper as follows. The signals were acquired from the 3-axis accelerometer, and then transmitted to the PDA through a Bluetooth module. This system can classify human activity, and also detect an emergency state like falls. When the fall occurs, the system generates the alarm on the PDA. If a subject does not respond to the alarm, the system determines whether the current situation is an emergency state or not, and then sends some information to the emergency center in the case of an urgent situation. Three different studies were conducted on 12 experimental subjects, with results indicating a good accuracy. The first study was performed to detect the posture change of human daily activity. The second study was performed to detect the correct direction of fall. The third study was conducted to check the classification of the daily physical activity. Each test lasted at least 1 min. in the third study. The output of the acceleration signal was compared and evaluated by changing various postures after attaching a 3-axis accelerometer module on the chest. The newly developed system has some important features such as portability, convenience and low cost. One of the main advantages of this system is that it is available at home healthcare environment. Another important feature lies in its low cost of manufacture. The implemented system can detect the fall accurately, so it will be widely used in emergency situations.

Gravity Removal and Vector Rotation Algorithm for Step counting using a 3-axis MEMS accelerometer (3축 MEMS 가속도 센서를 이용한 걸음 수 측정을 위한 중력 제거 및 백터 전환 알고리즘)

  • Kim, Seung-Young;Kwon, Gu-In
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.5
    • /
    • pp.43-52
    • /
    • 2014
  • In this paper, we propose Gravity Removal and Vector Rotation algorithm for counting steps of wearable device, and we evaluated the proposed GRVR algorithm with Micro-Electro-Mechanical (MEMS) 3-axis accelerometer equipped in low-power wearable device while the device is mounted on various positions of a walking or running person. By applying low-pass filter, the gravity elements are canceled from acceleration on each axis of yaw, pitch and roll. In addition to DC-bias removal and the low-pass filtering, the proposed GRVR calculates acceleration only on the yaw-axis while a person is walking or running thus we count the step even if the wearable device's axis are rotated during walking or running. The experimental result shows 99.4% accuracies for the cases where the wearable device is mounted in the middle and on the right of the belt, and 91.1% accuracy which is more accurate than 83% of commercial 3-axis pedometer when worn on wrist for the case of axis-rotation.