• Title/Summary/Keyword: 1,2-unit

Search Result 8,859, Processing Time 0.035 seconds

A Correlation Between Fibrinolytic Activity and Microflora in Korean Fermented Soybean Products (된장의 혈전용해효소 활성과 미생물 분포와의 상관관계)

  • 김동호;송현파;김기연;김정옥;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • A correlation between fibrinolytic activity and microflora in Korean traditional soybean fermented food was investigated. The fibrinolytic activities of traditional soybean pastes and commercially processed samples were 2.42$\pm$1.01 unit/g and 1.58$\pm$0.98 unit/g, respectively. The cell density of Bacillus in traditional soybean pastes was about 10$^{7}$ CFU/g and its commercially processed one was 10$^{6}$ CFU/g. Acid producing bacteria, fungi and yeast group were higher in commercially processed one. The correlations of fibrinolytic activity and microflora in traditional and commercial Doenjang were positively correlated in Bacillus ($R^2$≒ 0.69), negatively correlated in fungal group ($R^2$≒0.40), and there were no significant correlations in acid forming bacteria and yeast group ($R^2$<0.16). Fibrinolytic activities in Meju and Koji were 6.54$\pm$1.97 unit/g and 1.46$\pm$0.43 unit/g respectively, and were positively correlated with Bacillus. Yeast and acid forming bacteria were grown by 5∼6 decimal induction during fermentation period of Doenjang, but Bacillus, fungal cells and fibrinolytic activity were nearly stable. Results indicate that fibrinolytic activity of Doenjang depends on enzyme induction in Meju or Koji processing by Bacillus, Doenjang fermentation process.

Engineering Properties of Surlightweight Polymer Concrete (초경량 폴리머 콘크리트의 공학적 특성)

  • 성찬용;김경태
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.75-81
    • /
    • 1997
  • This study was performed to evaluate the engineering properties of surlightweight polymer concrete using synthetic lightweight aggregate. The following conclusions were drawn; 1. The unit weight was in the range of 0.849~0.969t/$m^3$, the unit weights of those concrete were decreased by 58 ~ 63% than that of the normal cement concrete. 2. The highest strength was achieved by $P_1$, and compressive strength was increased by 93% and bending strength by 364% than that of the normal cement concrete, respectively. 3. The ultrasonic pulse velocity was in the range of 2, 346~2, 702m/s, which was low compared to that of the normal cement concrete. 4. The dynamic modulus of elasticity was in the range of $1.561{\times} 10{^5}~1.916{\times} 10{^5}kgf/cm^2$, which was approximately 52~98% of that of the normal cement concrete. 5. The compressive and bending strength were increased with the increase of unit weight. But, the dynamic modulus of elasticity and ultrasonic pulse velocity were decreased with the increase of unit weight.

  • PDF

Analyses of SGTR Accident With Mihama Unit Experience (미하마 원전경험에 대한 SGTR 사고해석)

  • Lee, S.H.;Kim, K.;Kim, H.J.;Eun, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.41-53
    • /
    • 1994
  • A SGTR accident postulated at Kori unit 1 is simulated with Mihama unit experience, which occurred on February 1991, to evaluate the capability of plant to cope with the transient. The system design and plant conditions of Kori Unit 1 are much similar with those of Mihama Unit 2. Therefore, special concern has been given to evaluate the sequence and the resulting consequence of the postulated SGTR accident at the Kori unit 1 An analysis is peformed as realistically as possible, with following the EOP of Kori unit 1. The result indicates that the leak through tube break terminates within about forty minutes, and the Kori unit 1 may be sufficient to cope with SGTR accident with same type of sequence. However, the reconsideration may be required for the design of Kori unit 1 which disconnects non-safety AC power from off-site power on SI signal generation. It may be pointed out that the content of EOP for SGTR accident is not enough to require operator's proper judgements. An analysis of SGTR accident tested in the LSTF which simulated the SGTR accident at the Mihama Unit 2 is peformed using the RELAP5/MOD3. The results indicates that the code yields in general good agreement with the test, except the break flowrate at the early stage of the event.

  • PDF

Evaluation of Menu Management and Nutrition Supply in Industrial Foodservice by Food Cost (식품원가 분류에 따른 산업체급식의 식단관리 및 영양공급량평가)

  • Park, Myung-Hee;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.8 no.2
    • /
    • pp.91-101
    • /
    • 1993
  • Unit price of meal provision in industrial foodservice differs with each business. It is believed that menu management work, contents of menu, and nutrition supply performed by dietitian are different with unit price of meal provision. In this sense, purposes of this study are to examine meal management work and contents of menu, by food cost, at industrial foodservice in Taegu, Kyungbuk area and to evaluate variety of menu and nutrition supply. Results of the study are as follows: 1. Average number of side dishes provided at meal, including Kimchi, was 2 at low unit price, 3.0 at middle unit price and 3.1 at high unit price. 2. Possession ratio of account books using for menu management was low. 3. With regard to kind of menu, high unit price was most various and showed more various, compared to low unit price, especially in cooking oil-used cook methods such as broil, pan-fried food, fry, and roast. 4. High unit price was found as the highest in kind of used food and supply volume. 5. Sugar, Mineral, Vitamine, and Protein were satisfied with standard food content, but fat and calcium were not. 6. Supply volume of food was positively correlated to supply volume of nutrient, but kinds of cook methods and food type were not correlated to that of nutrient.

  • PDF

Electro-Thermal Characteristics of Hole-type Phase Change Memory (Hole 구조 상변화 메모리의 전기 및 열 특성)

  • Choi, Hong-Kyw;Jang, Nak-Won;Kim, Hong-Seung;Lee, Seong-Hwan;Yi, Dong-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.131-137
    • /
    • 2009
  • In this paper, we have manufactured hole type PRAM unit cell using phase change material $Ge_2Sb_2Te_5$. The phase change material $Ge_2Sb_2Te_5$ was deposited on hole of 500 nm size using sputtering method. Reset current of PRAM unit cell was confirmed by measuring R-V characteristic curve. Reset current of manufactured hole type PRAM unit cell is 15 mA, 100 ns. And electro and thermal characteristics of hole type PRAM unit cell were analyzed by 3-D finite element analysis. From simulation temperature of PRAM unit cell was $705^{\circ}C$.

The Effects of Delirium Prevention Intervention on the Delirium Incidence among Postoperative Patients in a Surgical Intensive Care Unit (외과계 중환자실 수술 후 환자의 섬망 예방 중재가 섬망 발생에 미치는 효과)

  • Shim, Mi Young;Song, Suk Hee;Lee, Mimi;Park, Min Ah;Yang, Eun Jin;Kim, Min Soo;Kim, Yu Jin;Kim, Toona
    • Journal of Korean Clinical Nursing Research
    • /
    • v.21 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • Purpose: This study was aimed to develop the multicomponent intervention for preventing delirium among postoperative patients in a surgical intensive care unit (SICU). Methods: Using a quasi-experimental pre & post-test design with a non-equivalent control group, a total of 88 hospitalized patients in a SICU participated in this study. The 44 patients were allocated in each experimental and control group. The experimental group received the multicomponent intervention for delirium prevention including a delirium assessment and nursing intervention using a checklist, whereas the control group was provided with a standard care. The primary outcome of this study was the delirium incidence during the course of hospitalization. Results: There were no significant differences in the demographic and clinical characteristics between the two groups. The delirium occurred in 19.2% in the experimental group, whereas 38.6% in the control group ($x^2=4.526$, p<.05). Conclusion: The findings of the study demonstrated an effect of the multicomponent delirium prevention intervention in decreasing the delirium incidence rate over the standard care among the patients in SICU.

A Fast Search Algorithm for Sub-Pixel Motion Estimation (부화소 움직임 추정을 위한 고속 탐색 기법)

  • Park, Dong-Kyun;Jo, Seong-Hyeon;Cho, Hyo-Moon;Lee, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.26-28
    • /
    • 2007
  • The motion estimation is the most important technique in the image compression of the video standards. In the case of next generation standards in the video codec as H.264, a high compression-efficiency can be also obtained by using a motion compensation. To obtain the accurate motion search, a motion estimation should be achieved up to 1/2 pixel and 1/4 pixel uiuts. To do this, the computational complexity is increased although the image compression rate is increased. Therefore, in this paper, we propose the advanced sub-pixel block matching algorithm to reduce the computational complexity by using a statistical characteristics of SAD(Sum of Absolute Difference). Generally, the probability of the minimum SAD values is high when searching point is in the distance 1 from the reference point. Thus, we reduced the searching area and then we can overcome the computational complexity problem. The main concept of proposed algorithm, which based on TSS(Three Step Search) method, first we find three minimum SAD points which is in integer distance unit, and then, in second step, the optimal point is in 1/2 pixel unit either between the most minimum SAD value point and the second minimum SAD point or between the most minimum SAD value point and the third minimum SAD point In third step, after finding the smallest SAD value between two SAD values on 1/2 pixel unit, the final optimized point is between the most minimum SAD value and the result value of the third step, in 1/2 pixel unit i.e., 1/4 pixel unit in totally. The conventional TSS method needs an eight.. search points in the sub-pixel steps in 1/2 pixel unit and also an eight search points in 1/4 pixel, to detect the optimal point. However, in proposed algorithm, only total five search points are needed. In the result. 23 % improvement of processing speed is obtained.

  • PDF

Characterization of Stormwater Pollutants and Estimation of Unit Loads for Road and Parking Lot in Gyeongan Stream Watershed (경안천지역의 도로 및 주차장에 대한 강우유출수의 특성분석과 원단위 산정)

  • Go, Sung-Hun;Memon, Sheeraz Amed;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.689-696
    • /
    • 2009
  • Unit load approach has been used to estimate the non-point pollutant load in Total Water Pollution Load Management System (TWPLMS). In this study, locally applicable unit loads for road and parking lot were developed based on the measurements of 9 rainfall events from 2007 to 2008 in Yongin city of Gyeongan stream watershed. Observations showed that stormwater runoff began at low precipitation (>1 mm) and peak pollutant concentration occurred at the beginning of the runoff because of impervious nature of the sites. Averaged event mean concentrations (EMCs) of road (parking lot) were estimated as COD 105.36(62.69) mg/L, BOD 15.94(13.20) mg/L, TSS 183.45(66.52) mg/L, T-N 4.63(3.28) mg/L, T-P 0.45(0.39) mg/L. Higher EMCs at the road than parking lot may reflect heavier traffic. Unit loads Estimated from the EMCs and 10 year average rainfall data were COD $331.17kg/km^2{\cdot}day$, BOD $50.20kg/km^2{\cdot}day$, TSS $580.13kg/km^2{\cdot}day$, T-N $14.68kg/km^2{\cdot}day$, T-P $1.43kg/km^2{\cdot}day$ in the road and COD $186.59kg/km^2{\cdot}day$, BOD $39.22kg/km^2{\cdot}day$, TSS $199.15kg/km^2{\cdot}day$, T-N $9.70kg/km^2{\cdot}day$, T-P $1.16kg/km^2{\cdot}day$ in the parking lot. The estimated unit loads are not so comparable to the ones listed in TWPLMS technical guideline and published data that locally developed unit loads should be used to estimate non-point pollutant loads.

SCALAR CURVATURE OF CONTACT CR-SUBMANIFOLDS IN AN ODD-DIMENSIONAL UNIT SPHERE

  • Kim, Hyang-Sook;Pak, Jin-Suk
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.3
    • /
    • pp.541-549
    • /
    • 2010
  • In this paper we derive an integral formula on an (n + 1)-dimensional, compact, minimal contact CR-submanifold M of (n - 1) contact CR-dimension immersed in a unit (2m+1)-sphere $S^{2m+1}$. Using this integral formula, we give a sufficient condition concerning with the scalar curvature of M in order that such a submanifold M is to be a generalized Clifford torus.