• Title/Summary/Keyword: 04A25

Search Result 1,415, Processing Time 0.042 seconds

Nonpharmacologic Pain Relief with Oral 25% Dextrose or/and Pacifier for Newborn Infants (신생아에서 비약물적 통증조절을 위한 25% 경구 포도당과 인공 젖꼭지 사용의 효과)

  • Kim, Min-Kyung;Kim, In-Ah;Jung, Min-Hee;Han, Myung-Ki;Park, Kie-Young;Kim, Bong-Seong;Jin, Hyun-Seong
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.353-358
    • /
    • 2011
  • Purpose: The goal of this study was to compare the efficacy of oral 25% dextrose treatment or/and pacifier for analgesia in healthy newborns during intramuscular injection of a hepatitis B vaccine. Methods: A prospective, randomized, partially blinded, clinical trial was performed in 132 healthy newborns. They were assigned randomly to 4 treatment groups: control group (2 mL distilled water), dextrose group (2 mL 25% dextrose), pacifier group, dextrose+pacifier group (pacifier coating with 25% dextrose) during intramuscular injection of hepatitis B vaccine. For all groups, Neonatal Infant Pain Scale (NIPS), Neonatal Facial Coding System (NFCS), Premature Infant Pain Profile (PIPP) scores were evaluated before the injection, during the injection, and at 2 minutes after the injection. Pain scores were compared among the 4 groups. Results: Maternal and neonatal characteristics were similar among the 4 groups. 25% dextrose treatment led to lower NIPS pain scores during injection (6.4${\pm}$0.9 vs. 5.5${\pm}$1.7, P=0.01) and after injection (1.6${\pm}$2.0 vs. 0.6${\pm}$0.9, P=0.01) and NFCS pain scores after injection (1.5${\pm}$2.3 vs. 0.7${\pm}$0.8, P=0.04) than control group. The number of neonates who feel the pain (indication of scores: NIPS${\geq}$4, NFCS${\geq}$3) decreased (9 (23.1%) vs. 0 (0%), P=0.04 via NIPS, 7 (17.9%) vs. 0 (0%), P=0.02 via NFCS). However, all treatment groups did not decreased PIPP scores, compared with the control group. Conclusion: Oral 25% dextrose is effective than distilled water or using pacifier with or without 25% dextrose in reducing pain during intramuscular injection of hepatitis B vaccinations. Further study based on this preliminary study need about nonpharmacologic management of pain in newborns.

Antioxidant Activity of Korean Gomchwi (Ligularia fischen) Extracts (국내산 곰취(Ligularia fischen) 추출물의 항산화 활성)

  • Lim, Hyun-Ji;Lee, Hea-Jin;Lim, Mi-Hye;Jung, Moom-Jung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1524-1532
    • /
    • 2021
  • In this study, Gomchwi (Ligularia fischen) derived from Taebaek-si, Gangwon-do was extracted with 70% ethanol (LFE) and antioxidant activity was measured. The following experimental techniques were used to evaluate the antioxidant efficacy of LFE. Total phenolic contents, ABTS/DPPH radical scavenging analysis, cell viability assay, NO assay, and quantitative real-time PCR technique. The content of polyphenol and flavonoid was each 113.97±0.37 mg GAE/g or 29.22±2.06 mg QE/g in LFE. DPPH radical scavenging activity was measured to be 25 ㎍/㎖ 11.26±0.95%, 50 ㎍/㎖ 17.12±0.63%, 100 ㎍/㎖ 29.54±0.36%, 250 ㎍/㎖ 68.31±0.28%, 500 ㎍/㎖ 75.12±0.05%, and 1000 ㎍/㎖ 75.75±1.57%. In addition, ABTS radical scavenging activity was identified as LFE 25 ㎍/㎖ 13.75±0.21%, 50 ㎍/㎖ 26.71±0.20%, 100 ㎍/㎖ 56.92±0.22%, 250 ㎍/㎖ 91.30±0.12%, 500 ㎍/㎖ 93.40±0.02, and 1000 ㎍/㎖ 93.19±0.04%. There was no significant cytotoxicity of LFE. NO production was significantly decreased to LFE 50 ㎍/㎖ 79.40±2.64%, 100 ㎍/㎖ 55.01±5.36%, and 200 ㎍/㎖ 30.93±3.11%. Also, the NOS2 gene expression was significantly reduced to LFE 50 ㎍/㎖ 0.94±0.11, 100 ㎍/㎖ 0.59±0.05, and 200 ㎍/㎖ 0.32±0.04. This result objectively confirmed the antioxidant effect of Gomchwi. We will continue to conduct in-depth research. Therefore, it is believed that the possibility of using Gomchwi as a cosmetic and functional food material can be established.

High performance X-band power amplifier MMIC using a 0.25 ㎛ GaN HEMT technology (0.25 ㎛ GaN HEMT 기술을 이용한 우수한 성능의 X-대역 전력 증폭기)

  • Lee, Bok-Hyung;Park, Byung-Jun;Choi, Sun-Youl;Lim, Byeong-Ok;Go, Joo-Seoc;Kim, Sung-Chan
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.425-430
    • /
    • 2019
  • This work describes the design and characterization of a X-band power amplifier (PA) monolithic microwave integrated circuit (MMIC) using a $0.25{\mu}m$ gate length gallium nitride (GaN) high electron mobility transistor (HEMT) technology. The developed X-band power amplifier MMIC has small signal gain of over 22.7 dB and saturated output power of 43.02 dBm (20.04 W) over the entire band of 9 to 10 GHz. Maximum saturated output power is a 43.84 dBm (24.21 W) at 9.5 GHz. Its power added efficiency (PAE) is 41.0~51.24% and the chip dimensions are $3.7mm{\times}2.3mm$, generating the output power density of $2.84W/mm^2$. The developed GaN power amplifier MMIC is expected to be applied in a variety of X-band radar applications.

Dielectric and Piezoelectric Properties of (Na,K)(Nb,Ta,Sb)O3 Ceramics doped with Nb2O5 (Nb2O5 첨가에 따른 (Na,K)(Nb,Ta,Sb)O3 세라믹스의 유전 및 압전 특성)

  • Byeon, Sun-Min;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.867-872
    • /
    • 2012
  • In this study, in order to develop excellent lead free piezoelectric ceramics for piezoelectric actuators application, $Li_{0.04}(Na_{0.50}K_{0.50})_{0.96}[(Nb_{0.86}Ta_{0.10}Sb_{0.04})_{0.994}Co_{0.015}]O_3+0.0025SrO+0.15\;wt%K_2CO_3+x\;wt%Nb_2O_5$ (x = 0 - 0.5 wt%) (abbreviated as LNKNTSCS-xN) ceramics were fabricated by a conventional sintering technique. the phase structure, microstructure and electrical properties were investigated with a emphasis on the influence of the $Nb_2O_5$ content. High electrical properties of $d_{33}$=234 pC/N, kp=0.392, ${\varepsilon}_r$=1,395, ${\rho}=4.70g/cm^3$ were obtained from the specimen with x=0.4 wt%, which suggests that the composition ceramics is a promising lead-free piezoelectric material.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Antioxidant components and antioxidant activities of mixtures with Sasa quelpaertensis Nakai and Ficus erecta var. sieboldii (좁은잎천선과 및 조릿대 혼합 추출물의 항산화 성분과 항산화 활성)

  • Kwon, Hee-Yeon;Choi, Sun-Il;Han, Xionggao;Men, Xiao;Jang, Gill-Woong;Choi, Ye-Eun;Kang, Jun-Chul;Cho, Ju-Hyun;Lee, Ok-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.369-376
    • /
    • 2020
  • The purpose of this study was to evaluate the antioxidant components and activities of HR02/04(8:2)-W, a mixture of S. quelpaertensis Nakai and F. erecta var. sieboldii. We investigated the p-coumaric acid, total flavonoid, and total phenol contents. To evaluate the antioxidant efficacy, we measured the 1,1-diphenyl-2-picrylhydrazyl (DPPH), 2,2'-azino-bis(3-ethylbenzthiazoline6-sulfonic acid) diammonium salt (ABTS) radical scavenging activity, FRAP activity, reducing power, and ORAC value. We observed the protective effect of hydrogen peroxide against cell damage in human dermal fibroblasts. As a result of the experiment, the p-coumaric acid, total flavonoid, and total phenol contents were 75.62±1.56 mg/100 g, 21.57±0.84 mg rutin equivalent (RE)/g, and 21.25±1.31 mg gallic acid equivalent (GAE)/g, respectively. In the experiments on antioxidant activity, HR02/04(8:2)-W was found to have significantly increased antioxidant activity. In the human dermal fibroblasts, the HR02/04(8:2)-W treated groups could effectively protect cells against oxidative damage. In this study, we confirmed that HR02/04(8:2)-W is a material with effective physiological antioxidant activity.

Development of Value-added Ketchup Products with Korean Chile Peppers(Capsicum annuum L.) and Their Sensory Evaluation (국내산 고추를 이용한 고추 케찹 개발 및 관능적 특성 평가)

  • Lee, Seul;Yoo, Kyung-Mi;Song, Soon-Ran;Park, Jae-Bok;Hwang, In-Kyeong
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The purposes of this study were to develop value-added sauce(ketchup) products with Korean advanced chile peppers (Capsicum annuum L.), determine their physicochemical characteristics, and conduct a sensory evaluation. American chile ketchup products were collected from American local favorites and analyzed based on their compositions. The Korean chile ketchup contained tomato paste(37.5%), Korean chile pepper(14.1%), sugar(14.8%), vinegar(14.1%), garlic(8.5%), herbs, plum extract, and oligosaccharide. Its physiochemical analysis showed: moisture $59.61{\pm}0.28%$, crude protein $2.18{\pm}0.11%$, crude lipid $1.99{\pm}0.04%$, crude ash $9.26{\pm}0.13%$, crude carbohydrate $26.97{\pm}0.48%$, reducing sugar $35.19{\pm}0.97%$, salt $3.04{\pm}0.04%$, acidity $2.22{\pm}0.01%$, pH $3.7{\pm}0.01$, and $^{\circ}brix\;36.3{\pm}0.14$. Korean chile ketchup showed higher overall acceptability compared to American local favorite chile ketchup. This result suggests the possibility for replacing chile ketchup products imported from foreign countries(USA and Europe).

Detection of circulating antigens in rats experimentally infected with Paragonimus westermani by ELISA (ELISA법을 이용한 폐흡충 감염 백서의 혈청내 항원 검출)

  • 용태순;김동수
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.141-148
    • /
    • 1987
  • Circulating antigens in rats experimentally infected with Paragonimus westermani were examined by ELISA. From a total of 22 albino rats, each fed with 25 metacercariae, blood samples were collected until 12 weeks after infection. The specific antibodies against P. westermani in the serum of an infected cat were purified by ammonium sulfate precipitation, DEAE anion-exchange chromatography and affinity chromatography serially. So-called double antibody sandwich ELISA method was used for the detection of circulating antigens. The results were as follows: Mean value of O.D. in control sera was O. 04 (S.D.=0. 04). After infection, mean O.D.(S.D.) values were changed serially: 0.03(0.01) at 0.5 week(3 days), 0.55(0.50) at 1 week, 0.69(0.45) at 1.5 week, O.20 (0.19) at 2 weeks and O.13(0.10) at 2.5 weeks of infection. They returned, thereafter, to the level before infection. When O. 16 (mean+3 S.D.) were considered as cut-off value, those higher than O. 16 were observed only in the sera collected between 1 and 2.5 weeks after infection. Average 8. 4 immature worms (2.2 from the lungs and pleural cavities; 6.2 from muscles) were recovered in a rat at 12 weeks after infection. The fact that circulating antigens were not detected after 3 weeks of infection was considered to the caused by the formation of antigen-antibady complexs.

  • PDF

Inhibiting Factors and Kinetics of Nonenzymatic Browning in Ginger(Zingiber officinale Roscoe) Paste Model System (생강 페이스트 모형액의 비효소적 갈색화 억제인자 및 반응속도)

  • 조길석;장영상;신효선
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.6
    • /
    • pp.1135-1139
    • /
    • 1997
  • Major factors inhibiting nonenzymatic browning in stored ginger paste were investigated using aqueous model systems with temperature, water activity, pH and sulfur compounds. Browning index and total gingerols were measured during storage. The rate of nonenzymatic browning reactions showed a strong depencence on temperature and pH and a negligible influence on water activity. It was also reduced by the addition of 0.04% N-actyl-L-cysteine(NAcCys), effectively. Activation energies for aqueous ginger model systems with and without 0.04% NAcCys were 29.0 and 25.8kcal/mole, respectively.

  • PDF

Separation of Cations on the Hydrophobic Reagent Coated Column (Hydrophobic Reagent를 흡착시킨 분리관에서의 양이온 분리)

  • Tae Yoon Eom;Kih Soo Cho;Youn Doo Kim
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.328-333
    • /
    • 1987
  • 1-eicosylsulfate($C_{20}H_{41}SO_4^-$) was coated onto 5 ${\mu}m$ C18 reversed phase column. Adsorption equilibrium was reached when 1.2l of $1.46{\times}10^{-4}M$ in 25% acetonitrile solution passed through the column. This coated column proved to be stable up to 10l of 0.05 M ${\alpha}$-HiBA eluent used. The column efficiencies of Eu, Nd, Ce and La measured were about 0.04 mm of HETP using 0.15M ${\alpha}$-HiBA eluent at a flow rate of 1.0ml/min. This column was used to separate some lanthanides and transition metal ions, andmshowed an excellent resolution, respectively.

  • PDF