• Title/Summary/Keyword: 0-Basic Path

Search Result 87, Processing Time 0.024 seconds

Papers : A Study for Optimal Measurement Parameter Selection of Turboprop Engine for Basic Trainer using Non - Linear GPA (논문 : 비선형 GPA 를 이용한 기본 훈련기 터보프롭엔진의 최적계측변수 선정에 관한 연구)

  • Gong,Chang-Deok;Im,Gang-Taek;Gi,Ja-Yeong;O,Seong-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.105-113
    • /
    • 2002
  • In this study, the steady state performance analysis program was developed for a turboprop engine, and its performance was analyzed at uninstalled and installed conditions. For the purpose of evaluation the developed program was compared with the performance data provided by the engine manufacturer and analysis results of GASTURB8.0 program. It was confirmed that the developed program was reliable because the results by the developed program were well agreed with those by GASTURB8.0 within %%. The linear and non-linear GPA(Gas Path Analysis) programs for performance diagnotics were developed, and selection of optimal measurement variables was studied. Furthermore, in order to investigate effects of the number and the kind of measurement variables, the linear and non-linear GPAs were analyzed with various measurement set. If the measurement parameters were properly selected, the reliable and economic faults detection might be possible even thought the small number of measuring parameters were used.

Differences between vocational education and training and vocational competency according to the career movement path of middle-aged Koreans (한국 중·장년층의 직업이동경로에 따른 직업교육훈련 및 직업역량의 차이)

  • Lee, Soo-Jeong;Kim, Yun-Jeong
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.491-499
    • /
    • 2020
  • The purpose of this study is to grasp the difference in vocational education and training and vocational competency according to the career movement path, targeting middle-aged Koreans (ages 40 to 64) who have experience in vocational mobility. A survey was conducted for a month in February 2020, and among the 1,224 data, 845 middle-aged adults who had moved within the last 5 years were selected. First, 69.0% of them moved to work, and 48.2% of them moved to 'employment→employment'. Second, among all groups, 80.6% did not participate in vocational education and training. Third, the 'employment→employment' group had the highest perception of job basic ability and job competency and job seeking skills compared to other groups. And the job competency of middle-aged workers who moved from 'employment to unemployment and housework (childcare)' appeared to be slightly lower than those of other groups.

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

Design of an Energy Efficient XOR-XNOR Circuit (에너지 효율이 우수한 XOR-XNOR 회로 설계)

  • Kim, Jeong Beom
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.878-882
    • /
    • 2019
  • XOR(exclusive-OR)-XNOR(exclusive NOR) circuit is a basic component of 4-2 compressor for high performance arithmetic operation. In this paper we propose an energy efficient XOR-XNOR circuit. The proposed circuit is reduced the internal parasitic capacitance in critical path and implemented with 8 transistors. The circuit produces a perfect output signals for all input combinations. Compared with the previous circuits, the proposed circuit has a 14.5% reduction in propagation delay time and a 1.7% increase in power consumption. Therefore, the proposed XOR-XNOR is reduced power-delay- product (PDP) by 13.1% and energy-delay-product (EDP) by 26.0%. The proposed circuits are implemented with standard CMOS 0.18um technology and verified through SPICE simulation with 1.8V supply voltage.

Agronomic Characteristics and Path-coefficients of Safflower (Carthamus tinctorius L.) Collections (잇꽃 수집종의 주요특성과 경로계수 분석)

  • Park, Gyu-Hwan;Jung, Do-Chul;Kim, Jae-Cheol;Jeon, Chi-Hyeong;Kim, Kyung-Min
    • Korean Journal of Medicinal Crop Science
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • This study was carried out to obtain the basic information on mating parents and selection for high yielding safflower breeding. Thirty nine world safflower lines, which had collected from 13 countries of origjn, were evaluated for major agronomic characters, correlation and path-coefficients. The results obtained were summarized as follows. Days to flowers ranged from 83 days to 100 days. Days to flower of most foreign lines were later than that of domestic lines. Plant height ranged from 75 cm to 162 cm. The plant height and stem diameter of most foreign lines were higher than those of domestic lines. The leaf number and size of domestic lines were much more than those of foreign lines. The total branch numbers of foreign lines were more than domestic lines. Particularly, the number of third branch ranged from 0 to 25 and there were none in domestic lines. The number of corolla of foreign lines was much more than that of domestic lines. The yield of foreign lines collected from Central Asia and United States of America were more than any others. Significantly positive correlations were observed between yield and days to flower, stem diameter, the number of branch and the number of corolla. In the analysis of path-coefficient, the highest direct effects on yield was the number of corolla followed by the number of total branch, whereas those of the number of second branch and stem diameter were negative.

Micro-Optical Bench Packaging for Thermo-Optic Tunable Filter (미세광학벤치를 이용한 열 가변 필터의 패키징)

  • 황병철;박헌용;이승걸;오범환;이일항;최두선;박세근
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1097-1100
    • /
    • 2003
  • Tunable thermo-optic filter for WDM system was designed and fabricated. The basic structure of the filter was a Fabry-Perot resonator and the center cavity layer was poly-Si. Quardraple layers of low and high refractive index materials were used as DBR mirrors. Tuning and transmission efficiencies was measured and compared with the simulation results. Tuning range of 9.4 nm can be obtained by 64.7$^{\circ}C$ temperature changes and tuning efficiency was 0.144nm/K. The filter is to be assembled onto the micro optical bench with fiber optical path.

  • PDF

A MODEL FOR PROTECTIVE BEHAVIOR AGAINST THE HARMFUL EFFECTS OF RADIATION FOR RADIOLOGICAL TECHNOLOGISTS IN MEDICAL CENTERS

  • Han, Eun-Ok;Moon, In-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.95-101
    • /
    • 2009
  • Protective behavior of radiological technologists against radiation exposure is important to achieve reduction of the patient doses without compromising medical achievements. This study attempts to provide a basic model for the sophisticated intervention strategy that increases the level of the protective behavior of the technologists. The model was applied to real situations in Korea to demonstrate its utility. The results of this study are summarized as follows: First, the protective environment showed the highest relationship in the factors considered, r=0.637 (p<0.01). Secondly, the important factors were protective environment in environment characteristics, expectation for the protective behavior 0.228 (p<0.001), self-efficacy 0.142 (p<0.001), and attitude for the protective behavior 0.178 (p<0.001) in personal characteristics, and daily patient -0.112 (p<0.001) and number of the participation in the education session for the protective behavior 0.074 (p<0.05). Thirdly, the final protective behavior model by a path analysis method had direct influence on the attitude 0.171 (p<0.01) and environment 0.405 (p<0.01) for the protective behavior, self efficacy 0.122 (p<0.01), expectation for the protective behavior 0.16 (p<0.01), and self-efficacy in the specialty of projects 0.154 (p<0.01). The acceptance of the model determined by the absolute fit index (GFI), 0.969, and by the incremental fit index (CFI), 0.943, showed very significant levels. Value of $x^2$/df that is a factor applied to verify the acceptance of the model was 37, which implies that the result can be accepted in the desirable range. In addition, the parsimonious fit index configured by AGFI (0.890) and TLI (0.852) was also considered as a scale that accepts the model in practical applications. In case of the establishment of some specific intervention strategies based on the protective behavior model against harmful radiation effects proposed in this study, the strategy will provide an effective way to prevent medical harmful radiation effects that could cause severe injuries to people.

The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam (치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Accurate knowledge of the distribution of contamination electrons ( which comes from mainly gantry head by Compton scattering, pair production, and tray: henceforth called leptons ) at the surface and in the first centimeters of tissue is essential for the clinical practice of radiation oncology. Such lepton tends to reduce or eliminate the ‘skin-sparing’ advantage of megavoltage photon beam radiotherapy, This information is needed to prescribe a absorbed dose to a skin volume at a few millimeter depth in high energy therapeutic radiation photon beam All experiments were done with 15 MV photon beam from a dual energy linear accelerator (Clinac 1800, Varian). Field size is defined by ranged from 10.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$. The absorbed dose and distribution of leptons in therapeutic radiation beam (15 MV) are investigated by means of variable blocked beams of 30.0$\times$30.0 $\textrm{cm}^2$ and dose beam profiles partly removed leptons with a copper plate. A numerous leptons mainly are distributed as shape of broad cone in the central photon beam and leptons path length in the water are shorter than 2.5 cm because of the leptons energy having around 3.0 MeV. These results clearly appears that the subtraction of leptons from the total depth dose curve not only lower the absolute dose in the buildup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth.

  • PDF

A Study on Behavioral Factors for the Safely of Ambulance Driving (일부지역에서 구급차운전자의 구급차 안전운전 운행행태에 관한 연구)

  • Jo, Jeanman;Lee, Byung-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.1 no.1
    • /
    • pp.100-111
    • /
    • 1997
  • This is the first Korea study to evaluate the effects od the safety of ambulance driving and the occurrence of ambulance traffic accidents and to provide basic informaion for the description of various factors to reduce the ambulance traffic accidents. The major insturment of this study were Krean Self-Analysis Driver Opinionnaire. Questionnaire contains 8 items which measure driver's opinions or attitudes : driving courtesy, emotion, traffic law, speed, vehicle conditions, the use of drugs, high-risk behaviors, and human factors. To take the analysis of data, the total of 350 divers were investigated ambulance divers and others in Taejon City and others (6 City) from 1996. 1. July to 1996. 31. July. The data were analyzed by the descriptive statistics and the logistic regression - path analysis - with SPSS and SAS package program. The result are as follows : 1. There was desirable attitude group(16.2%) and undesirable attitude group(17.6%) on safety ambulance driving. 2. It have suggested that risk factors of ambulance traffic accidents much affected with emotion and speed control on safety ambulance driving < Y(Accdient) = -2.64 + 0.57 $X_1$ (Emotion Control) + 0.30 $X_2$(Seed control) + E > and motor traffic acident much affected with emotion control and high-risk behavior on safety driving < Y(Accident) = -1.11 + 0.33 $X_1$(Emotion Control) + 0.29 $X_2$(High-risk Behvior) + E > 4. The primary emphassis of ambulance drivers was make us realized that improthatnt factors on safety ambulance driving were 1)making way for emergent ambulance, 2)driver's career, 3)The ability of emergency medical technics, and the knowledge or under standing of ambulance way difficut(or easy) of accdess. 5. Almost 96.6% of respondents have agreed to necessity of emergency medical technics for ambulance drivers. 6. Almost 94.6% of respondents have consented to necessity of emergtency medical technicians for ambulance driving. 7. It have suggested that the proportion of traffic accident proportion by desitable attitude group(16.7%) was much less than that of undesirable attitude group(30.8%) on safety ambulance driving(P < 0.05)/Ps) Accidents are unplanned, unforesen incidents which can lead to harmful or unfortunate outcomes, Collisons are not accidents, since the basic cause of the majority of collisons invovles high-risk human behavior. Although there are many factors which contribute to accident causation, four basic factors seem to predominate in most traffic related situations. These four factors include: the human factor, the vehicle factor, the environmental factors and destination factor(Peto G. et al. 1995).

  • PDF

Measurement and Comparative Analysis of Propagation Characteristics in 3, 6, 10, and 17 GHz in Two Different Indoor Corridors (두 가지 서로 다른 실내 복도에서 3, 6, 10, 17 GHz의 전파 특성 측정 및 비교 분석)

  • Seong-Hun Lee;Byung-Lok Cho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1031-1040
    • /
    • 2023
  • Propagation characteristics in line-of-sight(LOS) paths in 3, 6, 10, and 17 GHz frequency bands were measured and analyzed in two different indoor corridors: second floors of Buildings D2 and E2. The measurement was designed to measure when the receiving antenna moved at 0.5 m intervals from 3 m to 30 m, while the transmission antenna was fixed. The analysis of the two indoor corridors was compared by applying basic transmission loss, root mean square (RMS) delay spread, and K-factor. For basic transmission loss, the loss coefficient of the floating intercept path loss model was higher in the indoor corridor of Building E2 than in that of Building D2. Similarly, the RMS delay spread in the time domain was greater in the indoor corridor of Building E2. However, the indoor corridor of Building D2 exhibited higher K-factor in the 3, 6, and 17 GHz bands with lower wave propagation in the 10 GHz band. Despite the 2 indoor corridors being identical, the propagation characteristics varied due to different internal structures and materials. The results provide measurement data for ITU-R Recommendations regarding various indoor environments.