• Title/Summary/Keyword: 힘교정

Search Result 123, Processing Time 0.034 seconds

The effects of continuous and intermittent compressive pressure on alkaline phosphatase activity of MC3T3-E1 cells (지속적 및 간혈적 가압력이 MC3T3-E1 세포의 Alkaline phosphatase 활성도에 미치는 영향)

  • Song, Hye-Seob;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.449-454
    • /
    • 1996
  • The propose of this study was to evaluate the difference of cellular activity dependent on intermittent compressive force by determining the alkaline phosphatase activity. Alkaline phosphatase activity was measured on control and experimental groups every 24, 48, 72hours. Experimental groups consisted of continous and intermittent compressive group which were compressed by $300gm/cm^2$ of diaphram pump. The intermittent compressive group was connected by timer which was worked on 10 minutes an off 10 minutes. The results were as follows; 1. The alkaline phosphatase activity between control and experimental groups showed not significant difference at compressed 24 hours. 2. The alkaline phosphatase activity of experimental groups were more increased than control group at compressed 48 hours. 3. The alkaline phosphatase activity of intermittent compressive group showed significant increased to control group. Whereby continuous compressive group showed not significant difference to control at 72 hours. 4. The alkaline phosphatase activity of intermittent compressive group were stringly increased than continuous compressive groups. 5. Between experimental groups and control group no other morphologic changes were detected by microscopic findings.

  • PDF

The effect of cortical punching on the expression of OPG, RANK, and RANKL in the periodontal tissue during tooth movement in rats (백서의 치아이동 시 피질골 천공이 치주조직의 OPG, RANK, RANKL의 발현에 미치는 영향)

  • Park, Woo-Kyoung;Kim, Seong-Sik;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Deok;Jun, Eun-Sook;Park, Mi-Hwa
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.159-174
    • /
    • 2008
  • Objective: The purpose of this study was to investigate whether cortical punching could stimulate the expression of OPG, RANK, and RANKL during tooth movement by immunohistochemistry. Methods: 34 sprague-dawley rats (15 weeks old) were allocated into 3 groups: TMC group (experimental group; Tooth Movement with Corticotomy, n = 16), TM group (control group; Tooth Movement only group, n = 16), and non-treatment group (n = 2). 20 gm of orthodontic force was applied to rat incisors by inserting elastic bands. The duration of force application was 1, 4, 7 and 14 days. A microscrew (diameter 1.2 mm) was used for cortical punching of the palatal side of the upper incisors in the TMC group. Results: Distributions of OPG, RANK, and RANKL were evaluated by immunohistochemistry. OPG, RANK and RANKL were observed on experimental and control groups. On the compression side, the degree of the expression of OPG decreased in both groups. The expression of RANK was most prominent in the experimental group of day 4. The expression of RANKL was most intensive and extensive in the experimental group of day 7. However, the expression of OPG was decreased in the experimental and control groups compared to the non treatment group. The expression of OPG, RANK and RANKL after force application were decreased at day 14. Conclusions: These findings suggested that cortical punching might stimulate remodeling of alveolar bone during a 2 week period of tooth movement without any pathologic change.

Early Treatment of a Class II Malocclusion with the Trainer for Kids (T4K): A Case Report (Class II 부정교합환자의 Trainer for Kids(T4K)를 이용한 조기치료 : 증례보고)

  • An, So-Youn;Kim, Ah-Hyeon;Shim, Youn-Soo;Kim, Min-Jeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.101-110
    • /
    • 2013
  • $T4K^{TM}$(Myofunctional Research Co, Australia) is one of the myofunctional appliance developed to be used in children of mixed dentition. Myofuncitonal appliance stimulate the facial, masticatory and tongue muscle and help to balance the muscular force. Labial bow included in the device exerts strength in excessively labial inclineded upper jaw, Lip bumper blocks strength of the mouth to prevent abnormal strength exerted in lower jaw, Tongue tag secures proper position of tongue, and additional exercise is not required for child patients. For the more, simpler design and softer texture of device prmoted cooperation of patients during use. This case report is to present the satisfactory results gained by using $T4K^{TM}$ on Class II patients. Comment 1. $T4K^{TM}$ was applied in Class II malocclusion patients of mixed dentition with expected space insufficient to gain facial improvement. 2. Excessive overjet, overbite were improved. 3. Main effects are regarded to have been achieved by development of lingual slant of upper jaw, labial slant of lower jaw, and lower part of jawbone. 4. Bad habits, such as mouth breathing, can also be adjusted.

Shear bond strength of orthodontic adhesive to amalgam surface using light-cured resin (광중합형 레진으로 아말감 면에 브라켓 접착 시 전단결합강도)

  • Cho, Ji-Young;Lee, Dong-Yul;Lim, Yong-Kyu
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.443-450
    • /
    • 2005
  • This study was performed to compare the shear bond strength of orthodontic adhesive to amalgam according to different light sources (halogen-based light and light emitting diode (LED)) and amalgam surface treatments. Ninety extracted human premolars were randomly divided into 6 groups (4 experimental and 2 control groups) of 15 by light sources and surface treatments. Orthodontic brackets were bonded and shear bond strength was measured with an Instron universal testing machine. The findings were as follows: The bond strength of adhesive to amalgam surface was 3-5.5 MPa which was lower than that of acid-etched enamel (19 MPa) control. In the sandblasted amalgam surface, the shear bond strength of the halogen light group was higher than that of the LED group (p < 0.05) but. in the non-treated amalgam surface. there was no significant difference in the shear bond strength according to the light sources (p> 0.05). Within the same light source. sandblasting had no significant effect on the shear bond strength of the adhesive bonded to amalgam surface (p > 0.05). There was no significant difference in shear bond strength according to the light sources in acid-etched enamel control groups. This results suggest that there can be a limit in using light curing adhesives when brackets are bonded to an amalgam surface. Additional clinical studies are necessary before routine use of halogen light and LED light curing units can be recommended in bonding brackets to an amalgam surface.

Orthodontic protraction of the third molars to the posterior teeth missing area (구치 결손 환자에서 제3대구치의 교정적 활용)

  • Lee, Kang-gyu;Park, Je-Hyeok;Jeon, Jin;Kang, Jae-yoen;Kim, Jong Ghee;Jeon, Young-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.260-269
    • /
    • 2019
  • The prolonged neglect of the posterior teeth missing area may cause mesial drift, extrusion, unexpected movement of the adjacent teeth and alveolar bone loss with occlusion collapse. Therefore it is recommended to treat that area by the prosthesis as soon as possible after tooth missing. However, if orthodontic treatment is applied to move the remained teeth, it can create improved biomechanical dentoalveolar environment. The use of the third molars in teeth missing area provides advantages as optimizing of prosthesis size. However, crown shape, location, soundness of the third molar and possible of eruption failure should be considered. In this case report, two patients closed a second teeth missing site and reduced the size of the first and second teeth missing area for an implant by protraction of impacted third molars. This case reports the considerations for closing or reducing the posterior teeth space with protracting the third molars by comparing two patients.

A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics (Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구)

  • Yim, Kang-Soon;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.303-312
    • /
    • 2004
  • An unfavorable tipping movement can occur during the retraction of anterior teeth because orthodontic force is loaded by brackets positioned far from the center of resistance. To avoid this unfavorable movement, a compensating curved wire or lingual root torque wire is used. The purpose of this study is to investigate, using photoelastic material, the distribution of initial stress associated with the retraction of the incisors according to the degree of the compensating curve, to model changes associated with tooth ud alveolar bone structure. The following results were obtained by analysis of the polarizing plate of the effects of initial stress resulting from retraction of the anterior teeth: 1. When the incisors were retracted using combination archwire or sliding mechanics, the maximal polarizing pattern of the apical area decreased as the degree of the compensating owe increased from 0 to 15 to 30. 2. When the incisors were retracted by the combination archwire or sliding mechanics, the maximal polarizing pattern of the canine and premolar area increased as the degree of the compensating curve increased from 0to 15to 30. 3. A lower degree of polarizing patterns were associated with the combination archwire technique than the sliding mechanics technique at a given force. The above results indicate that there is no significant difference between the combination loop archwire technique and sliding mechanics, for the retraction of maxillary anterior teeth with decreased lingual tipping tendency by a compensating curve on the arch wire. However, the use of sliding mechanics is more effective for the prevention of lingual inclination of the anterior teeth, because the hook used in sliding mechanics is closer to the center of resistance of the maxillary anterior teeth.

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

Experimental brush wear pattern and cariostatic effect of Biscover (Biscover의 잇솔질에 따른 마모양상과 항우식 효과)

  • Oh, Eun-Ju;Park, Song-Soo;Jang, Mun-Ju;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.214-222
    • /
    • 2008
  • Objective: The aim of this study was to investigate the experimental brush wear pattern of a light cured surface sealant, Biscover (Bisco, Schaumburg, IL), and to evaluate its cariostatic effect. Methods: Caries-free human premolars were used for the Biscover coating group (n = 90) and the control group (n = 10). The Biscover coating group was randomly assigned to nine subgroups of 10 each and the control group was assigned to two subgroups of 5 each according to the number of brushing strokes. An experimental 3-body wear test was conducted under different strokes of wear test. Tooth-brushing was accomplished with movement of each brush head set at a frequency of 100 rpm under a force of 1.5N, Surface roughness was tested before, and after Biscover coating, and after brushing. Then, each of the 10 teeth of both groups were placed in artificial caries inducing solution for 7 days. All tooth surfaces were assessed using scanning electron microscopy. Results: Biscover coated surfaces showed a smoother texture than enamel surfaces. The roughness was increased after experimental brushing and after 10,800 brushing strokes, the whole layer of Biscover wore out. However, teeth in the Biscover coating group had a cariostatic effect in cariogenic conditions. Conclusions: We suggest that white lesions in orthodontic patients can be suppressed by topical applications of Biscover.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Spatial changes of the maxillofacial complex following maxillary protraction of human dry skull (건조 두개골에서 상악의 전방 견인후 상악 안면 복합체의 공간 변화에 관한 연구)

  • Chun, Youn Sic;Choi, Jang Woo;Choi, Seung Eun;Lee, Seong Geun
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.425-434
    • /
    • 2002
  • The purpose of this investigation was to study the spatial changes of the maxillofacial complex following maxillary protraction transmitted to the center of resistance of a dry juvenile human skull by a modified maxillary protraction appliance. Four dry juvenile human skulls (without mandible) with well aligned upper deciduous dentition and early mixed dentition were used as experimental samples. A modified protraction headgear was fabricated from a Delare's facemask, and following an alginate impression, an orthodontic resin maxillary splint was made for each dry skull. Protraction force level was maintained at approximately 1000gm per side for 6 hours. Cephalometric radiographs were taken pre- and post- protraction, and nine reference markers with 1.5 mm length of $.017\times.025$ TMA wire were placed on the right side of the skull for an accurate superimposition of serial cephalometric radiographs. The present investigation demonstrated that vertical changes associated with an anterior displacement of the maxillary complex was observed, and the most prominent effect of protraction headgear was a counterclockwise rotation of the maxilla, that is, a forward and downward tipping around the palatomaxillary region.