A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics

Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구

  • Yim, Kang-Soon (Department of Orthodontics, College of Dentistry, Dankook University) ;
  • Lee, Jin-Woo (Department of Orthodontics, College of Dentistry, Dankook University) ;
  • Cha, Kyung-Suk (Department of Orthodontics, College of Dentistry, Dankook University)
  • 임강순 (단국대학교 치과대학 교정학교실) ;
  • 차경석 (단국대학교 치과대학 교정학교실) ;
  • 이진우 (단국대학교 치과대학 교정학교실)
  • Published : 2004.08.01

Abstract

An unfavorable tipping movement can occur during the retraction of anterior teeth because orthodontic force is loaded by brackets positioned far from the center of resistance. To avoid this unfavorable movement, a compensating curved wire or lingual root torque wire is used. The purpose of this study is to investigate, using photoelastic material, the distribution of initial stress associated with the retraction of the incisors according to the degree of the compensating curve, to model changes associated with tooth ud alveolar bone structure. The following results were obtained by analysis of the polarizing plate of the effects of initial stress resulting from retraction of the anterior teeth: 1. When the incisors were retracted using combination archwire or sliding mechanics, the maximal polarizing pattern of the apical area decreased as the degree of the compensating owe increased from 0 to 15 to 30. 2. When the incisors were retracted by the combination archwire or sliding mechanics, the maximal polarizing pattern of the canine and premolar area increased as the degree of the compensating curve increased from 0to 15to 30. 3. A lower degree of polarizing patterns were associated with the combination archwire technique than the sliding mechanics technique at a given force. The above results indicate that there is no significant difference between the combination loop archwire technique and sliding mechanics, for the retraction of maxillary anterior teeth with decreased lingual tipping tendency by a compensating curve on the arch wire. However, the use of sliding mechanics is more effective for the prevention of lingual inclination of the anterior teeth, because the hook used in sliding mechanics is closer to the center of resistance of the maxillary anterior teeth.

전치의 후방 견인시 교정력은 치아의 저항중심에서 벗어난 브라켓을 통해 적용되기 때문에 바람직하지 못한 경사이동이 발생하게 되고 이를 방지하기 위한 여러 가지 방법 중 호선에 curve나 전치부 호선에 치근 설측 토그를 부여하는 방법이 많이 사용된다. 이에 본 연구는 combination loop archwire와 hook을 이용한 활주역 학을 이용하여 전치를 후방 견인 시, compensating curve를 0도, 15도, 30도 부여하고, 이 때 나타나는 효과를 광탄성법으로 비교 연구하기 위하여 치아와 치조골 모형을 광탄성 모형으로 대체시키고 와이어와 브라켓을 주어진 조건으로 위치시 킨 후 편광판을 이용하여 초기 응력 상태를 분석하여 다음과 같은 결과를 얻었다. 1. Combination loop archwire와 활주역학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 전치부 치근단 부위의 최대 무의차수가 감소하였다. 2. Combination loop archwire와 활주역 학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 견치와 소구치 부위의 최대 무의차수가 증가하였다. 3. Combination loop archwire로 전치를 견인할 때보다 동일한 힘을 사용하여 활주역 학으로 견인할 때 전치부 치근단 부위에서 다소 낮은 무의차수를 나타내었다. 이상의 결과에서 Combination loop archwire와 활주역학을 이용한 상악전치의 후방 견인시 견인방법에 큰 차이 없이 호선에 부여한 compensating curve는 전치의 설측 경사이동 양상을 어느 정도 감소시킬 수 있음을 확인하였다. 또한 힘의 적용위치가 저항중심에 더욱 가까운 hook을 이용한 활주 역학이 전치의 설측경사 방지에 더 효과적일 것으로 판단된다.가 높게 나타나는 현상을 부분적으로 설명하여 주는 것으로 사료된다.용한 정보를 제공할 수 있을 것으로 보인다.ing할 경우, arch perimeter의 증가량은 Curve of Spee의 최대 길이의 1/2보다 적게 나타났다.$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $61\%$ 수준이었으며, Non-etched Foil-Mesh base에서 최저 Peel 결합 강도$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $55\%$ 수준이었다. 4. 단위 면적 당 결합강도에 있어서 전단결합강도(SBS)와 인장결합강도(TBS) 및 $75^{\circ}\;와\;90^{\circ}$ peel 결합강도는 Micro-Loc base와 Chessboard base에서 차이 가 없었으며 Non-etched Foil-Mesh base에서 가장 작았고(p<0.05), $0^{\circ},\;15^{\circ},\;30^{\circ},\;60^{\circ}$ peel응력을 적용한 결과 Chessboard base에서 가장 큰 Peel결합강도를, Non-etched Foil-Mesh base에서 가장 작은 결합강도를 보였다(p<0.05).았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적 매끄러운 표면을 보이고, Unitek사의 경우 압흔과 함께 pitting 이 관찰되며, Ormco Stainless Steel의 경우 불규칙한 pitting이 다수 존재했다

Keywords

References

  1. Buchner HJ. Closing spaces in orthodontic cases. Angle Orthod 1953;23:158-65
  2. Gjessing P. Controlled retraction of maxillary incisors. Am J Orthod Dentofacial Orthop 1992;101:120-31 https://doi.org/10.1016/0889-5406(92)70003-S
  3. Bull. HL. Obtaining facial balance in the treatment of class II division1. Angle Orthod 1951:139-48
  4. Burstone CJ, The mechanics of the segmented arch technique. Angle Orthod 1966:36:99-120
  5. Jarabak JR, Fizzell JA. Technique and treatment with light wire edgewise appliances. Mosby; 1972
  6. Broussard. Applied concepts and uses of the Broussard 'Two force' technique. RMO Inc 1986
  7. McLaughlin RP. Bennett Jc. The transition from standard edgewise to preadjusted appliance systems. J Clin Orthod 1989;23:142-53
  8. Hajime Kosaka. Plane arch system. 지성출판사; 2001.
  9. Davidian EJ, Use of a computer model to study the force distribution on the root of maxillary central incisor. Am J Orthod 1971:59:581-8
  10. Kennedy DB. Joondeph DR, Osterberg SK, Little RM. Effect of extraction and orthodontic treatment on dentoalveolar support. Am J Orthod 1983;84:183-90 https://doi.org/10.1016/0002-9416(83)90125-2
  11. Kaley J, Phillips C. Factors related to root resorption in edgewisw practice. Angle Orthod 1991:61:125-32
  12. Ash MM. Wheeler’s dental anatomy, physiology and occlusion. 6th ed. Philadelphia: WE Saunders; 1984. p. 118-275
  13. 이유진, 박수병. 상악전치의 후방견인시 J hook headgear의 사용이 응력분포 변화에 미치는 영향에 대한 광탄성학적 연구. 대치교정지 1996;26:697- 709
  14. Burstone CJ, PIyputniewicz RJ, Holographic detennination of centers of rotation produced by orthodontic forces. Am J Orthod 1980;77:396-409
  15. Burstone CJ, Koenig HA. Creative wire bending -the force system from step and V bends. Am J Orthod Demtofacial Orthop 1988;93:59-67 https://doi.org/10.1016/0889-5406(88)90194-1
  16. Tanne K, Koenig HA, Burstone CJ, Moment to force ratios and the center of rotation. Am J Orthod Dentofacial Orthop 1988 : 94 : 426-31
  17. Faulkner MG, Lipsett AW, El-rayes K, Haberstock DL. On the use of vertical loops in retraction systems. Am J Orthod Dentofacial Orthop 1991:99:328-36
  18. Sleichter CG. A clinical assessment of light and heavy forces in the closure of extaction spaces. Angle Orthod 1971:41:66-75
  19. Baeten LR. Canine retraction: A Photoelastic study. Am J Orthod 1975;67:11-23 https://doi.org/10.1016/0002-9416(75)90125-6
  20. Gjessing P. Biomechanical design and clinical evaluation of a new canine retraction spring. Am J Orthod 1985;87:353-62 https://doi.org/10.1016/0002-9416(85)90195-2
  21. Vanden Bulcke MM, Burstone CJ, Sachdeva RC, Dermaut LR. Location of the centers of resistance for anterior teeth during retraction using the laser reflection technique. Am J Orthod Dentofacial Orthop 1987;91:375-84 https://doi.org/10.1016/0889-5406(87)90390-8
  22. 강정원, 차경석, 이진우. Intrusion arch wire activation시 상악견치에 가해진 초기응력의 유한 요소법을 통한 고찰. 대치교정지 1998;28:391-98
  23. 박춘근, 양원식. 상악 전치 intrusion시 저항중심의 위치에 관한 3차원 유한 요소법적 연구. 대치교정지 1997;27:259-72
  24. 민상홍, 윤영주, 김광원. Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구. 대치교정지 1995;25:143-52
  25. 천옥진, 김태우, 서정훈. 상악4절치의 후방견인시 나타나는 현상에 관한 유한요소적 연구. 대치교정지 1995;25:525-41
  26. Tanne K, Hiraga J, Kakiuchi K, Yamaggta Y, Sakuda M. Biomechanical effect of anteriorly directed extraoral forces on the craniofacial complex: a study using the finite element method. Am J Orthod Dentofacial Orthop 1989;95:200-7 https://doi.org/10.1016/0889-5406(89)90050-4
  27. 박기호, 손병화. Laser 반사측정법을 이용한 상악 전치부 함입시 저항 중심의 수평적 위치에 관한 연구. 대치교정지 1993;23:619-31
  28. Murphy NC, De Alba JA, Chaconas SJ, Caputo AA. Experimental force analysis of the contraction utility arch wire. Am J Orthod 1982;82 : 411-7 https://doi.org/10.1016/0002-9416(82)90190-7
  29. Pedersen E, Andersen K, Gjessing PE. Electronic detennination of centers of rotation produced by orthodontic force systems. Eur J Orthod 1990;12:272-80 https://doi.org/10.1093/ejo/12.3.272
  30. Pedersen E, Andersen K, Melsen B. Tooth displacement analysed on human autopsy material by means of a strain gauge technique. Eur J Orthod 1991;13:65-74 https://doi.org/10.1093/ejo/13.1.65
  31. 염정배, 이병태. Multiloop edgewise arch wire가 야기하는 응력분포에 관한 광탄성학적 연구. 대치교정지 1990;20:317-32
  32. Brodsky JF, Caputo AA, Furstman LL. Root tipping. A photoelastic histopathologic correlation. Am J Orthod 1975;67:1-10 https://doi.org/10.1016/0002-9416(75)90124-4
  33. Caputo AA, Chaconas SJ, Hayashi RK. Photoelastic visualization of orthodontic forces during canine retraction. Am J Orthod 1974;65:250-9 https://doi.org/10.1016/S0002-9416(74)90330-3
  34. Chaconas SJ, Caputo AA, Davis JC. The effects of orthopedic forces on the craniofacial complex utilizing cervical and headgear appliances. Am J Orthod 1976;69:527-39 https://doi.org/10.1016/S0002-9416(76)80026-7
  35. Levy AJ, Chaconas SJ, Caputo AA. Orthopedic effect of the extraoral chincup appliance on the mandible. Am J Orthod 1976;69:29-41 https://doi.org/10.1016/0002-9416(76)90096-8
  36. Ayala Perez C, De Alba JA, Caputo AA, Chaconas SJ, Canine retraction with J hook head gear. Am J Orthod 1980;78:538-47