• Title/Summary/Keyword: 희석

Search Result 4,059, Processing Time 0.039 seconds

Effects of Simulated Acid Rain on Nutrient Contents of Pinus densiflora S. et Z. and Forsythia koreana Nak. Seedlings (인공산성우(人工酸性雨)가 소나무 및 개나리묘(苗)의 식물체내(植物體內) 함유성분(含有成分)에 미치는 영향(影響))

  • Cheong, Yong Moon
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.259-268
    • /
    • 1988
  • For the purpose of examining the effects of simulated acid rain on nutrient contents of plant tissues in Pintos densiflora seedlings and Forsythia koreana rooted cuttings, the experimental design of randomized block arrangement with three replications was implemented in the experimental field of Yesan National Agricultural Junior College. One-year-old Pinus densiflora seedlings and Forsythia koreana cuttings were planted in the pots filled the mixed soils(nursery soil : forest soil of siliceous sandy loam=1 : 1 v/v) in the early spring of 1986. The regime of artificial acid rain, in terms of spray frequency per month and spray amount at single treatment per plot, was simulated on the basis of climatological data averaged from 30 years records. Simulated acid rain(pH 2.0, pH 4.0, and pH 5.5 as control) containing sulfuric and nutric acid in the ratio of 3 : 2(chemical equivalant basis) diluted with ground water were treated on the experimental plants under condition of cutting off the natural precipitation with vinyl tunnel, during the growing season(May 1 to August 31) in 1986. The results obtained in this study were as follow : (1) As for the nitrogen contents in plant tissues, P. densiflora increased significantly in one-year-old stembranch and root tissues, and F. koreana increased significantly in leaf and root tissues, as the pH levels of acid rain decreased. (2) The available phosphate contents in root tissues of P. densiflora, and in leaf and root tissues of F. koreana were significantly decreased, as the pH levels of acid rain decreased. (3) $K_2O$, CaO and MgO contents in plant tissues were significantly decreased in the both species as the pH levels decreased. And the effects of acid rain on F. koreana were higher than those of P. densiflora. (4) Sulfur contents of plant tissues in the both species were increased at pH 2.0 treatment. There were significant differences among three acid rain treatments in leaf and root tissues of P. densiflora, and in all parts of F. koreana. (5) In the effects of simulated acid rain on the both species and the tested soils, in general, F. koreana revealed higher sensitiveness than P. densiflora, and the lower pH levels of simulated acid rain were treated, the more sharp reaction was showed.

  • PDF

Comparison of Nutrient Replenishing Effect under Different Mixing Methods in a Closed-loop Soilless Culture using Solar Radiation-based Irrigation (적산 일사 제어법으로 관수하는 순환식 수경재배에서 배액 혼합 방식에 의한 재사용 양액 내 양분 조정효과 비교)

  • Ahn, Tae-In;Shin, Jong-Hwa;Noh, Eun-Hee;Son, Jung-Eek
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.247-252
    • /
    • 2011
  • Electrical conductivity, drainage, and irrigation amount of nutrient solution are important factors for determination of the mixing ratio of fresh and reused nutrient solutions in closed-loop soilless culture. Generally a fixed mixing ratio is applied in commercial scale greenhouses using solar radiation-based irrigation system. Although it ensures continuous supply of fresh nutrient solution in the mixing process, occasional discharge of the drainage is inevitably required. This study was conducted to compare the nutrient replenishing effect under different mixing processes and to investigate appropriate mixing process. For this experiment, a fixed mixing ratio (FR), modifiable mixing ratio (MR), and open-loop (OP) as control were applied. Mixing ratio was determined by a set value of EC for dilution of collected drainage in FR and the set values of 1.0 and $2.0dS{\cdot}m^{-1}$ were used as treatments (FR 1.0 and FR 2.0), respectively. In MR, mixing ratio was determined based on EC and volume of drainage within irrigation volume per event. The volume of drainage stored in the drainage tank tended to increase in FR 1.0. Although such trend was not observed in FR 2.0 and MR, the volume of drainage stored in MR was lower than that in FR 2.0. The ion balance of $Mg^{2+}:K^+:Ca^{2+}$ or $SO^{2-}_4:NO^-_3:PO^{3-}_4$ in the drainage and reused nutrient solution changed within a narrow range regardless of treatment.

Antioxidative Activities and Tyrosinase Inhibition Ability in Various Extracts of the Vitex rotundifolia Seeds (만형자(Vitex rotundifolia) 추출물의 항산화 활성과 Tyrosinase 저해 활성)

  • Lee, Yang-Suk;Choi, Bok-Dong;Joo, Eun-Young;Shin, Seung-Ryeul;Kim, Nam-Woo
    • Food Science and Preservation
    • /
    • v.16 no.1
    • /
    • pp.101-108
    • /
    • 2009
  • The purpose of this study was to measure flavonoid and polyphenol contents, and physiological activities of various extracts from Vitex rotundifolia seeds (known as Man Hyung Ja). We obtained three extracts using water (WE), ethanol (EE) and hot water (HWE). The EE sample had the highest flavonoid content of 31.05 mg/g. Polyphenol contents of WE and HWE were 186.69 mg/g and 182.55 mg/g, respectively. HWE had the highest superoxide dismutase (SOD)-like activity, at 83.40%. The electron donating abilities (EDA) were $91.14{\sim}95.97%$ at the concentration of 1.0 mg/mL, and all of extracts showed more than 88% EDA even at a concentration of 0.1 mg/mL. The inhibitory rates of xanthine oxidase were $94.02{\sim}97.51%$ when 1.0 mg/mL extracts were used, and all extracts showed more than 90% inhibition at 0.5 mg/mL. The nitrite scavenging abilities were $59.27{\sim}86.61%$ at pH 1.2 and 1.0 mg/mL extract concentration; these abilities decreased as pH increased. Tyrosinase inhibition activities of HWE and WE were 48.58% and 46.67%, respectively. These results indicate that Vitex rotundifolia seeds extract might be an effective antioxidative activity.

Removal Efficiency of the Deodorization Equipment and Characteristics of Malodor during the Process in Co-treatment of Sewage and Food Waste of Su-young Wastewater Treatment Plant in Busan (부산수영하수처리장 하수와 음식물쓰레기 병합처리 시 공정별 악취특성 및 후처리시설 효율평가)

  • Lee, Hyung-Don;Kang, Dae-Jong;Lee, Min-Ho;Kang, Dong-Hyo;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.379-389
    • /
    • 2012
  • Environmental issues are being paid more attention due to income growth, urban overcrowding, and population growth in Korea. Among the various environmental problems, odor damage is the one of the serious factors. To take example for food waste combination treatment in Su-young wastewater treatment plant in Busan, many complaints occurred because this plant locate around residential areas. The purpose of this work is not only to analyze odorous elements and their contributions but also to evaluate odor quotient (OQ), sum of odor quotient (SOQ), and treatment efficiency of bio-filter. The results of dilution sensory test of complex odor, grinder, leachate, hopper indicated higher order complex odors happen in July and August. The main odorous elements consisted of hydrogen sulfide, ammonia, methly mercaptan and acetaldehyde, which were analyzed by instrumental detection method, and methyl mercaptan was exceeded over 3,571 times of threshold. In addition, result of contribution of odor was methyl mercaptan (49.95 to 59.08%), hydrogen sulfide (20.43 to 29.27%), trimethylamine (8.82 to 13.42%) and acetaldehyde (9.17 to 11.35%). Other facilities were compared with the contribution of the odor using OQ and SOQ during the process. Sulfur compounds, acetaldehyde, and trimethylamine are high contribution of odor using OQ as well as odor intensity of grinding process is highest. As a result, sulfur compounds (e.g., methyl mercaptan and hydrogen sulfide) are highest for OQ and SOQ of grinding process is highest as 7,067. The removal efficiency of deodorization equipment was more than 90.00% in ammonia and amines, but the average efficiency of sulfur compounds was 53.51%. Thus, this facility is more higher contribution of acetaldehyde and trimethylamine than other treatment facilities. And food waste treatment in environmental area needs to consider appropriate capacity and refers to other bio-filter operating conditions.

Application of Polymerase Chain Reaction (PCR) to the Diagnosis of Tuberculosis (Polymerase Chain Reaction (PCR)을 이용한 결핵의 진단에 관한 연구)

  • Kim, Ho-Joong;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.517-525
    • /
    • 1992
  • Background: Since its development by Saiki et al, polymerase chain reaction (PCR) has been very useful in various fields of molecular biology. PCR can be used for the detection of a very small amount of microbial agent, and is especially useful in those patients who are difficult to diagnose microbiologically or serologically. Mycobacterium tuberculosis is a very slowly growing organism and AFB staining frequently shows false negative results, and therefore PCR would be a very rapid, easy, and sensitive diagnostic method for the diagnosis of Mycobacterium tuberculosis. Method: To compare PCR with conventional methods in diagnosing Mycobacterium tuberculosis in sputum, we used sputa of patients who visited or were admitted to Seoul National University Hospital. The amplification targets were 383 base pair DNA, a part of 2520 base pair DNA encoding 65 kD Mycobacterium tuberculosis specific protein (the primers are TB-1, -2), and 123 base pair DNA, a part of IS6110 fragment, which multiple copies are known to exsist PCR one genome (the primers are Sal I-1, -2). We also requested AFB staing and culture to the lab of Seoul National University Hospital with the same sample and compared the results. Results: 1) Using TB-1, -2 primers, PCR was positive in 73.1% (19/26) of culture positive sputa, in 12.5% (1/8) of culture negative. but clinically diagnosed tuberculous sputa, and was negative in all sputa of patients who were clinically diagnosed as non-tuberculous etiology. 2) Using Sal I-I, -2 primers, PCR was positive in 94.1% (32/34) of culture positive sputa, in 23.1% (6/26) of culture negative, but clinically diagnosed tuberculous sputa, and was negative in 87.5% (14/16) of sputa from patients who were clinically diagnosed as non-tuberculous etiology. Conclusion: PCR could be a very rapid, sensitive and specific method for the diagnosis of Mycobacterium tuberculosis in sputa, and further studies should be followed for the development of easier method.

  • PDF

Spontaneous and Stimulated Release of the TNF-$\alpha$, IL-1$\beta$, IL-6 and IL-8 of Alveolar Macrophages in the Patients with Pulmonary Tuberculosis (폐결핵 환자의 폐포 대식세포에서 TNF-$\alpha$, IL-1$\beta$, IL-6 및 IL-8의 분비에 관한 연구)

  • Cheon, Seon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.942-952
    • /
    • 1998
  • The aim of this study was to evaluate spontaneous and LPS stimulated proinflammatory cytokines and chemokine release of alveolar macrophages in the patients with pulmonary tuberculosis and healthy individuals, as a control. Alveolar macrophages recovered from bronchoalveolar lavage fluids were cultured with or without LPS 0.1, 1, or 10 ${\mu}g/ml$ for 24 and 48 hours in 37C, 5% CO2. TNF-$\alpha$, IL-1$\beta$, IL-6 and IL-8 amount were evaluated using ELISA kit from the supernatants. There were a significant increase in the spontaneous 24 hours release of TNF-$\alpha$ and IL-6 from the involved segments of tuberculosis patients compared with uninvolved segments and normal control There were also increasing trends of release of them after LPS stimulation in involved segments, but not significant. IL-1$\beta$ and IL-8 were not evaluated from the involved segments of tubeculosis and there were not significant differences of them between uninvolved segments of tuberculosis and normal control. It is concluded that cytokine release of alveolar macrophages in the pulmonary tuberculosis was markedly increased, and it was localized to the alveolar macrophages from the involved segments.

  • PDF

Lack of the Association between Microsatellite Polymorphism in Toll-like Receptor 2 Gene and Development of COPD (Toll-like Receptor 2 유전자의 Microsatellite 유전자 다형성과 만성폐쇄성폐질환 발생과의 연관성 결여)

  • Lee, Hee Seok;Lee, Hye Won;Kim, Deog Kyeom;Ko, Dong Seok;Park, Gun Min;Hwang, Yong Il;Lee, Sang-Min;Yoo, Chul Gyu;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.4
    • /
    • pp.367-374
    • /
    • 2005
  • Background : The fact that only 10-20% of chronic cigarette smokers develop chronic obstructive pulmonary disease (COPD) reflects the presence of genetic factors associated with the susceptibility to COPD. Recently, it was reported that the surfactant protein A increases the secretion of matrix metalloprotease 9, which degrades extracellular matrices of the lung, through a Toll-like receptor 2 (TLR2). In this context, possible role of TLR2 in the pathogenesis of COPD was postulated, and a functional dinucleotide repeat polymorphism in intron II of TLR2 was evaluated for any association with COPD. Method : Male patients with COPD and male smokers with a normal pulmonary function were enrolled in this study. The number of Guanine-Thymine repeats in intron II of the TLR2 gene were counted. Because the distributions of the repeats were trimodal, the alleles were classified into three subclasses, 12-16 repeats: short (S) alleles; 17-22 repeats: medium length (M) alleles; and 23-27 repeats: long (L) alleles. Result : 125 male patients with COPD and 144 age- and gender-matched blood donors with a normal lung function were enrolled. There were no differences in the distribution of each allele subclass (S, M and L) between the COPD and control group (p=0.75). The frequencies of the genotypes with and without each allele subclass in the COPD and control group were similar. Conclusion : A microsatellite polymorphism in intron II of TLR2 gene was not associated with the development of COPD in Koreans.

Polishing characteristics of polyetherketoneketone on Candida albicans adhesion (Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향)

  • Kim, Hyunyoung;Lee, Jonghyuk;Lee, Sung-Hoon;Baek, Dongheon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods: Specimens from PEKK (Group E) and PMMA (Group M) were made in dimensions of 8 mm in diameter and 2 mm in thickness. The specimens were further divided into sub-groups according to the extent of polishing (ER, MR: rough; EP, MP: polished, N = 12 each). The specimens were polished using polishing machine and SiC foil. ER and MR group specimens were polished with 600 grit SiC foil only. EP and MP groups were further polished with 800, 1,000, 1,200 grit SiC foils sequentially. To measure the surface roughness values (Sa) of specimens, atomic force microscope (AFM) was used and scanning electron microscope (SEM) observation under 1,000, and 20,000 magnifications was performed to investigate surface topography. The polished specimens were soaked in C. albicans suspension for 2 hours with shaking to promote adhesion. The attached C. albicans were detached from the surface with 10 times of pipetting. The suspension of detached C. albicans was performed by serial dilution to 103 times, and the diluted suspensions were inoculated on Sabouraud dextrose agar plates using spread plate method. After incubating the plate for 48 hours, colony forming unit (CFU)/plate of C. albicans was counted. Statistical analysis was performed using one-way ANOVA and Tukey HSD test to confirm significant difference between the groups (α=.05). Results: Average Sa value was significantly higher in MR group compared to other groups (P<.05), meaning that additional polishing steps reduced surface roughness effectively only in the PMMA specimens. There was no significant difference in Sa values between MP and EP groups. In SEM images, PEKK specimens showed numerous spikes of abraded material protruding from the surface and this phenomenon was more significant in EP group. The mean CFU/plate value was the highest in EP group and this was significant when it was compared to MP group (P<.05) which was the lowest. Conclusion: Polishing PEKK using serial SiC abrasive foil may result in higher adhesion of C. albicans. In clinic, this should be considered carefully.

EFFECTS OF SUBINHIBITORY CONCENTRATIONS OF ANTIMICROBIAL AGENTS ON CELL SURFACE PROPERTIES AND VIRULENCE FACTORS OF MUTANS STREPTOCOCCI (아저해농도(亞沮害濃度)의 항균물질이 mutans streptococci의 세포표면성질과 독력인자에 미치는 영향)

  • Kim, Young-Jae;Hahn, Se-Hyun;Lee, Sang-Hoon;Jang, Ki-Taeg;Kim, Chol-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.605-616
    • /
    • 2004
  • Subinhibitory concentrations (sub-MICs) refer to concentrations below minimum inhibitory concentrations (MICs). The antimicrobial agents may be present at relatively high concentration, at least higher than bacterial MIC and thereafter be deserted off a surface and function at sub-MICs, perhaps by interfering with bacterial metabolism. Consequently, the aim of this study was to determine the effects of growth, in the presence of sub-MICs of antimicrobial agents, on the cell surface properties and virulence factors of mutans streptococci and to investigate the efficacy of a chemical approach in vitro. Streptococcus mutans Ingbritt and Streptococcus sobrinus 6715-7 were used. Eight antimicrobial agents (Sanguinaria extract;SG, Chlorhexidine digluconate;CHX, Fluoride;F, Propolis;PP, Hydrogen peroxide;HP, Triclosan;TC, Sodium dodecyl sulfate;SDS Cetylpyridinium chloride; CC) were diluted serially in broth to determine MICs and to compare the growth rate, acid production, hydrophobicity, adhesion activity to saliva coated hydroxyapatite, glucan synthesis and cellular aggregation of experiment groups (in the presence of sub-MICs) with those of control (in the absence of antimicrobial agents). Sub-MICs of antimicrobial agents affected the growth of cells, hydrophobicity, and adhesion of bacteria to saliva coated hydroxyapatite and glucan synthesis. They also resulted in a significant reduction in pH after 12 hours (p<0.05). By cells pretreated with proteinase K, either the aggregation induced by antimicrobial agents was completely inhibited or the aggregation titers were markedly increased. According to the results of the present study, each antimicrobial agent at sub-MICs could affect similar as its known action mechanism and could continually inhibit cariogenic bacteria at such concentrations. Thus, the use of these antimicrobial agents would be one of the effective methods to prevent dental caries.

  • PDF

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.