• Title/Summary/Keyword: 흡수 분광법

Search Result 320, Processing Time 0.031 seconds

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Phantom Glucose Measurement by Near Infrared Reflection (근적외선 반사를 이용한 인체 팬텀의 글루코즈 농도 측정)

  • 전계진;황인덕;조혜민;한상준;윤길원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.250-251
    • /
    • 2002
  • 혈당의 비침습적인 측정의 필요성은 잦은 채혈로 인한 감염의 우려, 필요할 때마다 채혈의 고통 없이 혈당을 측정할 수 있다는 장점 때문에 지난 20여 년 동안 활발히 연구되어 왔다. 근적외선 및 원적외선 흡수분광법, 라만분광법, Polarization rotation 또는 Stimulated Raman 측정법, 온도측정법, 통계적 분석법, 전처리연구 등 많은 분야에서 접근하고 있지만 아직까지는 in vivo 측정에 성공하고 있지 못하고 있다 [1]. (중략)

  • PDF

저주파 및 고주파 구동 대기압 플라즈마 젯의 특성 비교

  • Gwon, Yang-Won;Baek, Eun-Jeong;Eom, In-Seop;Jo, Hye-Min;Kim, Seon-Ja;Jeong, Tae-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.194.2-194.2
    • /
    • 2016
  • 저주파 (수십 kHz)와 고주파 (13.56 MHz)로 구동되는 대기압 플라즈마 젯을 발생시키고, 인가전압 (혹은 인가전력)과 기체 유량에 따른 대기압 플라즈마의 특성을 비교하였다. 고주파에서 발생된 플라즈마는 저주파의 경우보다 안정적이었으며, 인가전압 (혹은 인가전력)이 증가함에 따라 플라즈마 기체온도는 상승하였고, 고주파 젯의 기체온도는 저주파 젯 보다 높았으나 330 K이하인 것을 확인하였다. Optical Emission Spectroscopy (OES)를 이용하여 저주파와 고주파의 광 방출 특성을 측정하였다. 저주파에서는 $N_2{^+}$ (391.4 nm)의 intensity 증가가 두드러지게 나타났지만 고주파 젯에서는 $N_2$, $N_2{^+}$의 intensity는 감소하였으며, OH, NO, $H_{\alpha}$, O와 같은 활성 산소 종 (Reactive Oxygen Species)이 저주파 젯 보다 높게 측정되었다. Boltzmann plot method를 이용한 분석을 통해 저주파와 고주파 영역에서의 플라즈마 전자 여기 온도를 측정하였다. 또한 자외선 흡수분광법을 이용하여 플라즈마-액체 계면에서의 OH이 입자밀도를 측정하여 OES방법으로 측정한 OH 밀도와 비교하였다. 그리고 화학적 측정법 (terephtalic acid solution)을 이용하여 액체 내의 OH의 농도를 측정하였다.

  • PDF

Laser absorption spectroscopy of ternary gas mixture of He-Ne-Xe in External Electrode Fluorescent Lamp (EEFL) (레이저 흡수 분광법을 이용한 He-Ne-Xe 상종가스의 외부전곡 램프의 $1s_4$ 공명준위와 $1s_5$ 준안정준위의 제논 원자 밀도에 대한 연구)

  • Jeong, S.H.;Oh, P.Y.;Lee, J.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.576-580
    • /
    • 2006
  • Mercury-free lamp, external electrode fluorescent lamp (EEFL) which includes the xenon gas, is now going on the research for the replacement of mercury lamp. The densities of excited xenon atom in the $1s_4$ resonance state and the $1s_5$ metastable state are investigated in the EEFL by a laser absorption spectroscopy under various gas pressures. We have measured the absorption signals for both $1s_4$ resonance and the $1s_5$ metastable state in the EEFL by varying the discharge currents for a given pressure. This basic absorption characteristic is very important for improvement of the VUV luminous efficiency of the EEFL as well as plasma display panel.

Polarization dependence on Cavity Ringdown Spectroscopy (공동 광자감쇠 분광학에서의 편광의존성)

  • 김재완;한재원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.216-217
    • /
    • 2000
  • 상자성을 갖는 분자에 대한 분광학 연구에서는 제만(Zeeman) 효과로 생기는 이색성을 이용한 magnetic rotation spectroscopy (MRS)가 널리 사용되고 있다.$^{(1)}$ MRS가 일반적인 흡수 분광법에 비해 더 민감한 측정을 할 수 있기는 하지만 사용하는 편광기의 extinction ratio에 의해 감도가 한정된다. MRS의 감도를 높이는 방법으로는 광경로를 길게 만드는 것을 고려할 수 있다. 일반적으로 공진기 광자감쇠 분광학(Cavity Ring-Down Spectroscopy, CRDS)은$^{(2)}$ 높은 반사율을 갖는 거울을 사용해서 수 km 이상의 광 경로를 만들기 때문에 감도가 높다. (중략)

  • PDF

Spectroelectrochemical Study for Thin Film of Gold Nanoparticles (금 나노입자 박막의 분광전기화학적 연구)

  • Seo, Seong S.;Chambers, James Q.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.32-36
    • /
    • 2006
  • films of gold nanoparticles were formed on indium tin oxide (ITO) by an electrodeposition method from an aminosilicate stabilized gold colloid solution. The thin films were examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), UV-visible, and energy dispersive X-ray spectroscopy (EDXS). The surface coverage of gold nanoparticles on the thin film was estimated to 1.2 nanomole/cm2. An anthraquinone-2, 6-disulfonic acid, disodium salt (AQDS) self-assembled layer was generated by immersing gold thin film into 1mM of AQDS in 0.1M HClO4 solution for over 20 hours. As a result, a new absorbance peak from the multi-layers (AQDS/thin film of gold /ITO) was obtained about at 690 nm. Also, the surface plasmon absorption of multi-layers was measured by UV-Visible spectrometer along with chronoamperometry by applying the various potentials from +0.5V to -0.5V. The maximum surface plasmon absorption band at 550 nm was decreased by applying negative potentials. The change of absorbance was correlated with the surface coverage of the AQDS indicating the pseudo-capacity surface state of the AQDS layer was coupled to the energy level of the plasmonband by applied negative potentials.

작업환경중 금속시료의 적정 분석에 관한 연구(크롬)

  • Kim, Seok-Won
    • 월간산업보건
    • /
    • s.90
    • /
    • pp.2-8
    • /
    • 1995
  • 원자 흡수 분광법과 용매 추출을 이용한 크롬의 정량분석 조건을 연구하였다. tertiary amine류 중 octy기를 갖는 trioctylamine(TOA)과 quaternary ammonium salt류 중 octy1 기를 갖는 trioctylmethylammonium chloride(TOMAC)가 음이온 교환기로 사용되었다. 또한 첨가되는 산의 종류와 산의 농도 변화에 따라서 원자흡수분광기를 이용하여 흡광도를 측정하였다. TOA사용시 염산의 농도가 0.1M-0.3M사이, TOMAC사용시 염산의 농도가 0.03M-0.1M사이에서 최대 흡광도를 나타내었다. 산이 첨가된 MIRK에 용해된 TOA나 TOMAC와 Cr과의 mole농도 비율이 1:1이상이 된 것이 최대 추출효율을 보았다. 추출과정을 검토한 결과, 본 실험에서 사용된 방법은 비슷한 다른 방법들과 비교하여 보면 크롬의 추출효율이 좋은 것으로 판명되었다.

  • PDF

Optimum Angle between Pump Beam and Probe Beam in the Differential-Velocity-Selective Saturation Absorption Spectroscopy (차동속도선택 포화흡수분광법에서 펌프광과 조사광의 최적 각도)

  • Cho, Chang-Ho;Park, Jong-Dae
    • The Journal of Natural Sciences
    • /
    • v.12 no.1
    • /
    • pp.49-59
    • /
    • 2002
  • Exponential decrease of saturation absorption signal was reported in pump beam spacially keeping off from probe beam. Optimum angle between pump beam and probe beam in the differential-velocity-selective saturation absorption spectroscopy was computed theoretically, $1.33^{\circ}$ in cesium atoms and $1.08^{\circ}$ in Rb 87 atoms, and was good agreement with the experimental results.

  • PDF

반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기

  • O, Chang-Hun;Ryu, Hun-Cheol;Lee, Hyeong-U;Kim, Se-Yeon;Lee, Heon-Jeong;Han, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.412-412
    • /
    • 2010
  • 플라즈마는 미세 전기 소자 제작에 있어 박막의 증착, 식각, 세정등 여러 가지 공정에서 널리 사용되고 있다. 미세 소자의 선폭의 감소와 높은 생산성을 위한 웨이퍼 면적의 대형화가 진행됨에 따라 플라즈마의 균일도는 공정 수율 향상의 관점에서 중요한 요소로 그것의 계측과 공정 중 실시간 감시에 필요성이 부각되고 있다. 플라즈마에 존재하는 라디칼의 밀도, 이온의 밀도, 전자 온도 등의 웨이퍼 상에서의 공간 분포와 공정 결과물과의 상관관계에 대한 연구는 현재까지 다양하게 진행 되었으며 특히, 라디칼의 공간 분포가 공정 결과물의 균일도와 큰 상관 관계가 있는 것으로 알려져 있다. 라디칼의 농도 분포를 계측은 레이저 유도 형광법, 발광 분광법, 흡수 분광법 등을 통하여 이루어져 왔으며, 특히 발광 분광법의 경우 계측의 민감성, 편의성등을 이유로 가장 널리 사용되고 있다. 그러나 현재 까지 진행된 발광 분광법을 이용한 라디칼의 공간 분포 계측은 그 자체로 공간 분포를 계측하는 것이 아닌 플라즈마 밀도의 축 대칭성을 가정하여 Abel inversion을 적용하거나, 광섬유를 플라즈마에 직접 삽입하는 방식을 사용하기 때문에 실제 반도체 제작공정을 비롯한 미세소자 공정 플라즈마의 라디칼 밀도 분포를 실시간, 비 접촉 방식으로 계측 하는데 한계가 있다. 본 연구에서는 반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기를 제안한다. 기존의 발광 분광법과 비교하여 공간 분해능 향상을 위하여 직렬로 설치된 다수의 렌즈, 개구, 그리고 핀홀을 이용하였다. 공간 분해 발광 분광기의 공간 분해능을 계산하였으며, 실험을 통하여 검증 하였다. 또, HDP CVD를 이용한 $SiO_2$ 박막 증착 공정에서 산소 라디칼의 농도와 증착된 박막의 두께 분포의 상관 관계를 계측 함으로써 공간 분해 발광 분광기의 플라즈마 공정 적용 가능성 입증 하였다.

  • PDF

Evaluation of Concentration and Reaction Kinetics through Color Analyses (색상 분석법을 이용한 농도 및 촉매반응속도 측정)

  • Lee, Euna;Chang, Ji Woong
    • Applied Chemistry for Engineering
    • /
    • v.33 no.3
    • /
    • pp.279-283
    • /
    • 2022
  • UV-vis spectroscopy is one of the powerful tools for measuring the concentrations of reactant and products during a chemical reaction. However, there is an limitation of using the technique when the reaction undergoes in high concentration and high temperature. Color analysis using camera images can provide the identical results with UV-vis analysis with regardless of the sample concentration and temperature. The catalytic reduction reaction of resazurin to resorufin was investigated using the color analysis with the color spaces such as CIE L*a*b*. Moreover, the color analysis enabled the independent analysis of two different material's concentrations without the deconvolution of overlapped wavelengths unlike the case of using UV-vis spectroscopy.