• Title/Summary/Keyword: 흡수성능

Search Result 886, Processing Time 0.029 seconds

Analysis of Bioconversed-components in Fermented Jaeumganghwa-tang by Lactobacillus (Lactobacillus로 발효한 자음강화탕의 생물전환 성분분석)

  • Lee, Kwang Jin;Song, Na-Young;Roh, Joo-Hwan;Liang, Chun;Ma, Jin Yeul
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.3
    • /
    • pp.131-135
    • /
    • 2013
  • Jaeumganghwa-tang (JGT) is a traditional herbal medicine used for chronic bronchitis and inflammatory diseases. The variation in the amount of bioactive components of JGT and its fermentation JGT with ten species of microorganism was investigated via high performance liquid chromatography coupled with diode array detection (HPLC-DAD). Simultaneous qualitative and quantitative analysis of eight bioactive compounds; 5- hydroxymethylfurfural (5-HMF), paeoniflorin, nodakenin, hesperidin, nodakenetin, palmatine, berberine and glycyrrhizin were achieved by comparing their retention times ($t_R$) and UV spectra with those of the standard compounds. In the result, the paeoniflorin amount was 6.95 mg/g that as a main compound in JGT. The amount of nodakenetin was the highest in the fermented-JGT with Lactobacillus fermentum KFRI 145 ($0.47{\pm}0.01mg/g$), which was increased by 2,250% compared to that in non-fermented JGT ($0.02{\pm}0.00mg/g$). In the fermented JGT using Lactobacillus acidophilus KFRI 162, most components were increased than non-fermented JGT, except paeoniflorin and hesperidin.

Drop Impact Analysis of Outside Cooling Unit Package of System Air-Conditioner and Experimental Verification (시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험적 검증)

  • Kim, Hyung-Seok;Lee, Boo-Yoon;Lee, Sanghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • This research examines the drop impact of an external cooling unit package of an air conditioner system. The packaging is composed of a shock-absorbing material, which protects the package contents by absorbing the impact energy and other parts for fixture. Accurate quantification of the impact acceleration experienced by the package contents is necessary to design an effective packaging with minimal volume and sufficient shock absorbing capacity. Explicit time integration was used for the drop impact analyses. A finite element model of the package was constructed, material testing and material model selection were carried out, and sensors for data acquisition were modeled to obtain accurate simulation results. The results were compared with real physical test data. Due to imprecise modeling of the damping, the acceleration and strain values predicted by the simulation were larger than those from physical test. However, the trend of the history data and the peak deceleration value in the direction of impact showed good agreements. Thus, the analysis model and scheme are suitable for the design of an air conditioner cooling unit package.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices : Bone Absorptiometric X-ray System (엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Kim, Eun-Rim;Lee, Jun-ho;Lee, Chang-Hyung;Park, Chang Won
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.263-271
    • /
    • 2016
  • The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

Effect of sonicates of Treponema denticola on osteoblast differentiation (Treponema denticola 분쇄액에 의한 조골세포분화 억제효과)

  • Choi, Bong-Kyu;Kang, Jung-Hwa;Jin, Seung-Wook;Ohk, Seung-Ho;Lee, Syung-Il;Yoo, Yun-Jung
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.79-89
    • /
    • 2003
  • 치주질환은 세균감염에 의해 치조골이 파괴되는 염증성질환으로서 치아상실의 주된 원인이다. Treponema denticola는 성인성 치주염의 병소에서 자주 발견되는 세균으로서 부착능 및 단백분해효소생성능과 같은 독성 인자가 밝혀져 치주조직 파괴에 있어서 중요성이 강조되어 왔다. 골개조는 조골세포의 골형성및 파골세포에 의한 골흡수의 균형에 의하여 유지되며 치주염시 야기되는 치조골파괴는 조골세포 및 파골세포 기능의 불균형에 의하여 야기되는 것으로 설명되고 있다. 골세포에 대한 영향으로서 T. denticola는 파골세포의 형성을 촉진시키는 것으로 보고되었으나 조골세포에 대한 영향은 아직 밝혀져 있지 않다. 따라서 본 연구에서는 T. denticola가 골형성에 미치는 영향을 알아보고자 마우스의 두개골세포로부터 조골세포를 분리한 후 T. denticola분쇄액으로 처리하여 본 세균이 조골세포의 alkaline phosphatase(ALPase) 활성, 석회화결절 형성 및 Prostaglandin $E_2\;(PGE_2)$ 생성에 미치는 영향을 평가하였다. ALPase활성은 p-nitrophenylphosphate분해능, 석회화결절형성은 Von Kossa 염색법, 그리고 PGE2의 농도는 효소면역측정법으로 측정하였다. T. denticola분쇄액 (2.5 ug/ml)은 마우스 두개골세포의 ALPase활성을 억제하였으며 석회화결절의 형성을 감소시켰다. 또한 동일한 농도의 균분쇄액은 마우스 두개골세포의 $PGE_2$ 생산을 증가시켰다. 균분쇄액과 prostaglandin의 합성억제제인 indomethacin으로 세포를 동시에 처리한 경우 T .denticola분쇄액에 의한 $PGE_2$의 생산은 감소되었으나, ALPase의 활성억제에는 변화가 없었다. 균분쇄액을 열처리하여 마우스 두개골세포에 처리하였을 때에도 ALPase의 활성이 억제되는 것에는 변함이 없었다. 이러한 결과는 T. denticola의 구성성분 중 열에 안정한 물질이 prostaglandin과 무관한 경로를 통해 조골세포의 분화를 억제함을 시사하며 이와 같은 T. denticola에 의한 골형성억제가 치주염시 야기되는 치조골 파괴에 관여할 수 있을 것으로 생각된다.

Characteristics of EVA-Polymer Modified Mortars Recycling Rapid-chilled Steel Slag Fine Aggregate (급냉 제강슬래그를 재활용한 EVA-폴리머 시멘트 모르타르의 특성)

  • Hwang, Eui-Hwan;Kim, Jin-Man
    • Applied Chemistry for Engineering
    • /
    • v.19 no.6
    • /
    • pp.652-660
    • /
    • 2008
  • For the recycling of rapid-chilled steel slag, the mechanical strengths and physical properties of EVA-polymer modified mortars with the various replacement ratios of rapid-chilled steel slag were investigated. Twenty five specimens of polymer modified mortars were prepared with the five different amounts of EVA-polymer modifier (0, 5, 10, 15, 20 wt%) and rapid-chilled steel slag (0, 25, 50, 75, 100 wt%). For the investigation of the characteristics of polymer modified mortars, the measurements such as water-cement ratio, unit volume weight, air content for fresh mortar and compressive strength, flexural strength, water absorption, hot water resistance, porosity and SEM investigation for curing specimens were conducted. As a results, with an increase in the replacement ratio of rapid-chilled steel slag, water-cement ratios decreased but unit volume weight increased remarkably. With increasing EVA-polymer modifier and the replacement ratio of rapid-chilled steel slag, percent of water absorption decreased but compressive and flexural strengths increased remarkably. By the hot water resistance test, mechanical strengths decreased but total pore volume and porosity increased remarkably. In the SEM observation, the components of specimen were shown to stick to each other in the form of co-matrix phase before hot water resistance test, but polymer modifier of co-matrix phase was decomposed or deteriorated after hot water resistance test.

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

A Study on the Dielectric Properties of SBS/Conductive Filler/Dielectrics Composites for Phantom Model (팬텀 모델 제작을 위한 SBS/도전체/유전체 3상 복합재료의 유전특성 연구)

  • Kim, Yoon-Jin;Choi, Hyung-Do;Cho, Kwang-Yun;Yoo, Don-Sik;Yoon, Ho-Gyu;Suh, Kwang-Seok
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.98-107
    • /
    • 2001
  • Dielectric properties and shape memory characteristics of SBS composites filled with carbon black as conductive filler and (Ba,Ca)$(Sn,Ti)O_3$ or $SrTiO_3$ as dielectrics were investigated for the development of phantom model. SBS/carbon black composite showed an increment of complex dielectric constant with increasing the content of carbon black and the frequency dependence that the dielectric constant decreases with the frequency. The complex dielectric constant and the conductivity of SBS/carbon black/dielectrics composites increased with the increase of dielectrics and the characteristics of the frequency dependence also occurred by the effect of carbon black. Phantom materials with the dielectric properties and the conductivity corresponding to human tissues for the measurement of specific absorption rate(SAR) within the frequency range of current mobile phones(775MHz~2GHz) could be developed by adjusting the composition ratios of carbon black, dielectrics and SBS and by controlling the characteristic of frequency dependence of composite. From thermomechanical cycling test good shape recoverability could be obtained in SBS composite even though the residual strain was increased by the effect of filler.

  • PDF

Evaluation of Dynamic Tensile Strength of HPFRCC According to Compressive Strength Level (압축강도 수준에 따른 HPFRCC의 동적충격 인장강도 평가)

  • Park, Gi-Joon;Kim, Won-Woo;Park, Jung-Jun;Moon, Jae-Heum;Kim, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.31-37
    • /
    • 2018
  • This study evaluates the dynamic tensile behavior of HPFRCC according to compressive strength levels of 100, 140 and 180 MPa. Firstly, the compressive stress-strain relationship of 100, 140 and 180 MPa class HPFRCC was analyzed. As a result, the compressive strengths were 112, 150 and 202 MPa, respectively, and the elastic modulus increased with increasing compressive strength. The static tensile strengths of HPFRCC of 100, 140 and 180 MPa were 10.7, 11.5 and 16.5 MPa, and tensile strength also increased with increasing compressive strength. On the other hand, static tensile strength and energy absorption capacity at 100 and 140 MPa class HPFRCC showed no significant difference according to the compressive strength level. It was influenced by the specification of specimen and the arrangement of steel fiber. As a result of evaluating the dynamic impact tensile strength of HPFRCC, tensile strength and dynamic impact factor of all HPFRCCs tended to increase with increasing strain rate from 10-1/s to 150/s. In the same strain rate range, the DIF of the tensile strength was measured higher as the compressive strength of HPFRCC was lower. It is considered that HPFRCC of 100 MPa is the best in terms of efficiency. Therefore, it is advantageous to use HPFRCC with high compressive strength when a high level of tensile performance is required, and it is preferable to use HPFRCC close to the target compressive strength for more efficient approach at a high strain rate such as explosion.

Constructing Database for Drugs and its Application to Biological Sample by HPTLC and GC/MS (HPTLC와 GC/MS를 이용한 의약품의 데이타베이스화 및 생체시료에의 응용)

  • Yoo, Young-Chan;Park, Sung-Woo;Lim, Mie-Ae;Baeck, Seung-Kyung;Park, Seh-Youn;Lee, Ju-Seon;Lho, Dong-Seok
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.136-150
    • /
    • 2000
  • For the identification of unknown drugs in biological samples, we attempted rapid high performance thin layer chromatographic method which is sensitive and selective chromatographic analysis of high performance thin layer chromatography (HPTLC) with automated TLC sampler and ultra-violet (UV) scanner. We constructed HPTLC database (DB) on two hundred five drugs by using the data of Rf values and UV spectra (scan 200-360 nm) as well as gas chromatography/mass spectrometry (GC/MS) DB on ninety six drugs by using the data of relative retention time (RRT) on lidocain and mass spectra. After extracting drugs in biological sample by solid phase extraction (Clean Screen ZSDAU020), we applied them to HPTLC and GC/MS DB. Drugs, especially extracted from biological samples, showed good matching ratio to HPTLC DB and these drugs were confirmed by GC/MS. In conclusion, this DB system is thought to be very useful method for the screening of unknown drugs in biological samples.

  • PDF

A Study on the Material Characteristics and the Welding Properties of 600MPa Grade Steel (SM 570 TMC) (600MPa급(SM 570 TMC) 강재의 소재 및 용접특성에 관한 연구)

  • Kim, Jong Rak;Kim, Sang Seup;Lee, Chul Ho;Lee, Eun Taik;Beak, Ki Youl
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.773-781
    • /
    • 2008
  • As buildings are becoming taller and longer-spanned, the requirements of high-strength and reliable steels are becoming increasingly stringent. Structural steels, however, acquire significantly different mechanical properties when their strength becomes higher. In this study, the mechanical properties, welding characteristics, and conformities of the 600MPa-grade high-strength steel were tested. The 600MPa-grade steel plates exhibited stable criterion strengthvalues and showed low carbon equivalents (${\mathcal{Ceq}}$) and composition (${\mathcal{Pcm}}$) as well as excellent welding hardness. In the tensile strength test, all the specimens were found to have strengths of over 600MPa. In the Sharphy impact test, the impact-absorbed energy of the V-notch specimens was shown to be 47J at the KS limit. Moreover, the maximum hardness of the specimens in the weld-heat-affected zone at a normal temperature was the same as that before welding. Their weld metal properties, however, were found not to be as good as those of high-strength steel. As such, the details of high-strength steel must be determined.