• Title/Summary/Keyword: 흡수선량 평가

Search Result 208, Processing Time 0.025 seconds

The evaluation of absorbed dose of rectum for the patient of intracavitary treatment $^{60}$ Co by MgB$_4$O$_{7}$ (Mn) TLD (MgB$_4$O$_{7}$ (Mn) TLD에 의한 $^{60}$ Co 강내 치료 환자의 직장의 흡수선량 평가)

  • 유명진;신병철;문창우;정태식;염하용;도시홍
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.21-26
    • /
    • 1994
  • By measuring with TLD, absorbed dose of rectum will be determined more accurately than calculated value. MgB$_4$O$\sub$7/(Mn) TLD phosphor was prepared and its characteristic was studied. To measure the absorbed dose of rectum with TLD, 33 patients who had intracavitary treatment with $\^$60/Co from April 1994 to September 1994 at Kosin Medical center. There were 10-59% differecne in most cases between the calculation and the measurement for the absorbed dose of rectum. The difference was less the case with tandem and ovoid than the case with only ovoid.

  • PDF

Evaluation of Absorbed Dose according to the Use of Bolus in Opposite Breast during Radiation Therapy of Breast Cancer using VMAT (VMAT를 이용한 유방암 방사선치료 시 반대편 유방의 Bolus 사용에 따른 흡수선량 평가)

  • Kim, Jong-Bo;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.763-768
    • /
    • 2018
  • Although the development of radiation therapy techniques has made the treatment more precise, exposure by radiation is unavoidable beyond the treatment site. In this study, we wanted to evaluate the absorbed dose according to the thickness of the bolus on the opposite side of the treatment in radiation treatment for breast cancer and to analyze the effect of dose reduction. An experiment was conducted on Rando phantom using VMAT treatment methods. Five points of A, B, C, D, and E were selected for the breast opposite the treatment, and when the dosimeters of 5, 10, 15, and 20 mm were used. The highest absorbed dose at point D closest to the treatment point was measured and lowest at point B furthest from the treatment point. The mean absorbed dose was 8.61 cGy When the bolus is not used and 8.10, 7.94, 8.06, and 8.10 cGy Depending on the thickness of the bolus. In this study, bolus was intended to be used to analyze the dose-reducing effects of breasts on the other side of the treatment. The results of the study showed the effect of dose reduction and the appropriate bolus thickness should be set up to reduce the dose in normal tissues.

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

Image-based Absorbed Dosimetry of Radioisotope (영상기반 방사성동위원소 흡수선량 평가)

  • Park, Yong Sung;Lee, Yong Jin;Kim, Wook;Ji, Young Hoon;Kim, Kum Bae;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2016
  • An absorbed dose calculation method using a digital phantom is implemented in normal organs. This method cannot be employed for calculating the absorbed dose of tumor. In this study, we measure the S-value for calculating the absorbed dose of each organ and tumor. We inject a radioisotope into a torso phantom and perform Monte Carlo simulation based on the CT data. The torso phantom has lung, liver, spinal, cylinder, and tumor simulated using a spherical phantom. The radioactivity of the actual absorbed dose is measured using the injected dose of the radioisotope, which is Cu-64 73.85 MBq, and detected using a glass dosimeter in the torso phantom. To perform the Monte Carlo simulation, the information on each organ and tumor acquired using the PET/CT and CT data provides anatomical information. The anatomical information is offered above mean value and manually segmented for each organ and tumor. The residence time of the radioisotope in each organ and tumor is calculated using the time activity curve of Cu-64 radioactivity. The S-values of each organ and tumor are calculated based on the Monte Carlo simulation data using the spatial coordinate, voxel size, and density information. The absorbed dose is evaluated using that obtained through the Monte Carlo simulation and the S-value and the residence time in each organ and tumor. The absorbed dose in liver, tumor1, and tumor2 is 4.52E-02, 4.61E-02, and 5.98E-02 mGy/MBq, respectively. The difference in the absorbed dose measured using the glass dosimeter and that obtained through the Monte Carlo simulation data is within 12.3%. The result of this study is that the absorbed dose obtained using an image can evaluate each difference region and size of a region of interest.

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

Evaluation of the Output Dose of a Linear Accelerator Photon Beams by Using the Ionization Chamber TM31010 Series through TG-51 Protocol to Postal Monitoring Output of RPC for 5 Years (TM31010 계열의 공동이온전리함과 TG-51을 이용한 선형가속기광자선의 5년간 출력선량 평가)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • This study is to keep the accuracy and stability of the output dose evaluations for linear accelerator photon beams by using the air ionization chambers (TM31010, 0.125 cc, PTW) through the Task Group 51 protocol. The absorbed dose to water calibration factor $N_{dw}{^{Co-60}}$ was delivered from the air kerma calibration factor $N_k$ which was provided from manufacture through SSDL calibration for determination of output factor. The ionization chamber of TM31010 series was reviewed the calibration factor and other parameters for reduce the uncertainty within ${\pm}2%$ discrepancy and we found the supplied $N_{dw}{^{Co-60}}$ which was derived from Nk has shown a -2.8% uncertainty compare to that of PSDL. The authors provided the program to perform the output dosimetry with TG-51 protocol as it is composed same screen of TG-51 worksheets. The evaluated dose by determination of output factor delivered to postal TLD block for comparison the output dose to that of MDACC (RPC) in postal monitoring program. The results have shown the $1.001{\pm}0.013$ for 6 MV and $0.997{\pm}0.012$ discrepancy for 15 MV X rays for 5 years followed. This study shows the evaluated outputs for linear accelerate photon beams are very close to that of international output monitor with small discrepancy of ${\pm}1.3%$ with high reliability and showing the gradually stability after 2010.

Evaluation of the Usefulness of Digital Tomosynthesis in the Chest (흉부영역에서 디지털 토모신테시스의 유용성 평가)

  • Jang, Dong-Hyuk;Shim, Sung-Shine;Choi, Jae-Wook;Choi, Jun-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.340-348
    • /
    • 2012
  • To evaluate the usefulness of tomosynthesis in the chest area, simple radiograph, low-dose CT, and tomosynthesis examinations were performed, and their absorbed doses were compared, and finally the images were evaluated. The absorbed dose recorded with the simple Radiograph examination was $0.33{\pm}0.27$ mGy, that of low-dose CT $1.26{\pm}0.56$ mGy, and that of tomosynthesis $0.55{\pm}0.02$ mGy, which indicate significance differences in absorbed doses among the examinations(p<0.001). Based on the evaluations of the images, The simple radiograph scores were $1.66{\pm}0.72$, $1.61{\pm}0.63$, and $1.57{\pm}0.73$, respectively; low-dose CT scores were $2.92{\pm}0.26$, $2.91{\pm}0.29$, and $2.88{\pm}0.32$, respectively; and tomosynthesis scores were $2.69{\pm}0.51$, $2.76{\pm}0.43$, and $2.66{\pm}0.61$, respectively. That is, there were statistically significant differences among the examinations(p<0.001), although there was no significant difference between low-dose CT and tomosynthesis examinations. Therefore, tomosynthesis is judged to be a useful examination that can minimize radiation doses to patients during chest examinations and enhance diagnostic efficacy.

Evaluation of Photoneutron Dose in Radiotherapy Room Using MCNPX (MCNPX를 이용한 방사선 치료실의 광중성자 선량 평가)

  • Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.283-289
    • /
    • 2015
  • Recently, high energy photon radiotherapy is a growing trend for increasing therapy results. Commonly, if you use high energy photons above 6~8 MeV nominal accelerator voltage, It lead the photo-nuclear reaction and the generation of photo-neutron are accompanied and these problematic factors are issued in the view of radiation protection. Therefore, in this study analyzed for dose distribution of photo-neutron in radiotherapy room based on MCNPX. As a result, absorbed dose is increased sharply from 10 MV to 12 MV. It was founded that the rapid increasement of photoneutron fluence was related to the absorbed dose at above 10 MV. Also, in case of the recommendation of ICRP 103, the outcome of an exchanged equivalent dose which based on calculated an absorbed dose, showed lower equivalent dose than ICRP 60 by reflecting the contribution of secondary photon for absorbed dose of human body in the low energy band.

Assessment of Absorbed Dose of by Organ according to Thyroidal Uptake of Radioactive Iodine for Adult Korean Males (한국성인 남성을 대상으로 한 방사성옥소의 갑상선 섭취율에 따른 각 장기별 흡수선량 평가)

  • Kim, Junghoon;Lim, Changseon;Whang, Jooho
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.187-193
    • /
    • 2007
  • In an effort to assess the internal absorbed dose of radionuclides that is suitable to Koreans' physiological characteristics, we asked 28 male Koreans to take $^{131}|$ orally, determined the thyroidal uptake and daily urination ratio, and assessed the absorbed dose by organ. As a result, first, 24 hours after administering, the average thyroidal uptake and the daily urination ratio registered 19.70% and 71.12%, respectively. Second, the whole body effective dose according to the thyroidal uptake calculated herein and the existing ICRP-suggested thyroidal uptake of 30% offered 1.464E-08 Sv and 2.189E-08 Sv, respectively, showing a 1.5 times difference. To evaluate the quantity of the absorbed dose of radioactive iodine, we can better reduce the error in assessing the body exposure dose by conducting measurement according to human races rather than depending on the existing ICRP data.

  • PDF