Assessment of Absorbed Dose of by Organ according to Thyroidal Uptake of Radioactive Iodine for Adult Korean Males

한국성인 남성을 대상으로 한 방사성옥소의 갑상선 섭취율에 따른 각 장기별 흡수선량 평가

  • Kim, Junghoon (Department of Nuclear Engineering, College of Advanced Technology, Kyung Hee University) ;
  • Lim, Changseon (Department of Radiotechnology, Konyang University) ;
  • Whang, Jooho (Department of Nuclear Engineering, College of Advanced Technology, Kyung Hee University)
  • 김정훈 (경희대학교 원자력공학과) ;
  • 임창선 (건양대학교 방사선학과) ;
  • 황주호 (경희대학교 원자력공학과)
  • Received : 2007.08.16
  • Accepted : 2007.11.05
  • Published : 2007.12.31

Abstract

In an effort to assess the internal absorbed dose of radionuclides that is suitable to Koreans' physiological characteristics, we asked 28 male Koreans to take $^{131}|$ orally, determined the thyroidal uptake and daily urination ratio, and assessed the absorbed dose by organ. As a result, first, 24 hours after administering, the average thyroidal uptake and the daily urination ratio registered 19.70% and 71.12%, respectively. Second, the whole body effective dose according to the thyroidal uptake calculated herein and the existing ICRP-suggested thyroidal uptake of 30% offered 1.464E-08 Sv and 2.189E-08 Sv, respectively, showing a 1.5 times difference. To evaluate the quantity of the absorbed dose of radioactive iodine, we can better reduce the error in assessing the body exposure dose by conducting measurement according to human races rather than depending on the existing ICRP data.

한국인의 생리적 특성에 맞는 방사성핵종의 체내 흡수선량 평가를 위한 일환으로 한국 성인 남성 28명을 대상으로 $^{131}|$을 경구투여 후 갑상선섭취율 및 소변 일일배설률을 산정하고 각 장기별 흘수선량을 평가하였다 그 결과, 첫째, 투여 24시간 후 갑상선이 평균 19.70%의 섭취율과 71.12%의 소변 일일배설률을 나타냈다. 둘째 본 연구에서 산출한 갑상선섭취율과 기존 ICRP에서 제시하는 갑상선섭취율 30%에 따른 전신유효선량은 각각 1.464E-08 Sv, 2.189E-08 Sv로 약 1.5배의 차이를 나타났다. 정량적인 방사성 옥소의 흡수선량 평가를 위해서는 기존 ICRP에서 제시하는 자료에 의존하기 보다는 인종별 새로운 측정을 통해 각 핵종별 자료의 확보만이 체내피폭평가시 오류를 최소화 할 수 있다.

Keywords