• Title/Summary/Keyword: 흡수선량 평가

Search Result 208, Processing Time 0.028 seconds

Assessment of Inhalation Dose Sensitivity by Physicochemical Properties of Airborne Particulates Containing Naturally Occurring Radioactive Materials (천연방사성물질을 함유한 공기 중 부유입자 흡입 시 입자의 물리화학적 특성에 따른 호흡방사선량 민감도 평가)

  • Kim, Si Young;Choi, Cheol Kyu;Park, Il;Kim, Yong Geon;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.216-222
    • /
    • 2015
  • Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of $0.01{\mu}m$ sized particulates were higher than doses due to $100{\mu}m$ sized particulates by factors of about 100 and 50 for $^{238}U$ and $^{230}Th$, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of $11g{\cdot}cm^{-3}$ and $0.7g{\cdot}cm^{-3}$ resulted in dose difference by about 60 %. For $^{238}U$, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of $^{238}U$ was about 9 times higher than dose for absorption F. For $^{230}Th$, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of $^{230}Th$ was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and conditions and use the site specific particulate properties to accurately access radiation dose to workers at NORM processing facilities.

Effects of AMAD, Absorption Type, and Intake Pattern on the Result of Evaluation for Internal Dose by Inhalation of Uranium (우라늄의 입자크기, 흡수형태 및 섭취형태가 내부피폭선량 평가 결과에 미치는 영향)

  • Lee, Jong-Il;Lee, Tae-Young;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.321-325
    • /
    • 2003
  • The effects of AMAD, absorption type, and intake pattern were compared and analysed for the internal dose evaluation of workers who chronically inhale uranium. The committed effective doses$(E_{50})$ based on AMAD, absorption type, and intake pattern were evaluated using 3 monthly lung predicted monitoring data due to a chronic intake of uranium for 5 years. The relative error ranges of $E_{50}$ evaluated with each AMAD$(0.1{\sim}10{\mu}m)\;to\;E_{50}$ evaluated with $5{\mu}m$ AMAD were $-37.0{\sim}49.8%$, and the relative error ranges of En evaluated with Type M to $E_{50}$ evaluated with Type S were $15.9{\sim}56.6%$, and the relative error ranges of $E_{50}$ evaluated with an acute intake to $E_{50}$ evaluated with a chronic intake were $0.55{\sim}4.52%$. Thus AMAD and the absorption type affected the results of $E_{50}$, but the intake pattern didn't really affect the results of $E_{50}$.

Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry (인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.933-939
    • /
    • 2019
  • The purpose of this study is to provide basic clinical data by evaluating images, measuring absorbed dose and effective dose by using high resolution CT and low dose CT by using anthropomorphic chest phantom and glass dosimeter. Tissue dose was measured by inserting a glass dosimeter into the anthropomorphic chest phantom. A 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany) and CARE Dose 4D were used, and the parameters of the high resolution CT were 120 kVp, Eff. Scan parameters of mAs 104, scan time 7.93 s, slice 1.0 mm (Acq. 64 × 0.6 mm), convolution kernel (B60f sharp) were used, and low dose CT was 120 kVp, Eff. mAs 15, scan time 7.41 s, slice 3.0 mm (Acq. 64 × 0.6 mm), scan of convolution kernel B50f medium sharp. CTDIvol was measured at 8.01 mGy for high resolution CT and 1.18 mGy for low dose CT. Low dose CT scans showed 85.49% less absorbed dose than high resolution CT scans.

Evaluation of Absorbed Dose According to the Gold Nanoparticle Density in Prostate Cancer Brachytherapy (전립선암의 근접치료 시 금 나노입자 밀도에 따른 흡수선량평가)

  • Lee, Deuk-Hee;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.247-252
    • /
    • 2019
  • This study was evaluated absorbed dose according to the gold nanoparticle density in prostate brachytherapy which was constantly occurred in Korean men. Absorbed dose evaluation was using MCNPX program which was applied Monte Carlo simulation. Source were applied $^{192}Ir$ which was temporary insertion source and $^{103}Pd$ which was permanently insertion source. And gold nanoparticle density was applied 0 mg, 7 mg, 18 mg and 30 mg. The prostate absorbed dose was increased in proportion to the density 2.95E-14 Gy/e to 4.42E-14 Gy/e in $^{192}Ir$ and showed the same tendency in $^{103}Pd$. And surrounding organ absorbed dose was inversely proportional to the density. Therefore using nanoparticle in brachytherapy was increased therapeutic ratio.

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter (열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가)

  • Kim, Sang-Tae;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.336-343
    • /
    • 2010
  • Coronary artery CT angiography has short scanning length, the exposure dose is high. Therefore, it is required to study on the organ dose when using MDCT. We compared the differences between the absorbed dose and effective dose in the major organs assessing the absorbed dose in the major organs by 16-MDCT and 64-MDCT in the subjects with coronary artery CT angiography, the same protocol by 16-MDCT and 64-MDCT. As a result, the great orders of absorbed dose when conducting coronary artery CT angiography had been shown as heart, stomach, liver, pancreas, kidney, spleen, large intestine, lung, small intestine, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$ in 16-MDCT, and heart, stomach, pancreas, spleen, liver, kidney, small intestine, large intestine, lung, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$ in 64-MDCT, demonstrating some different distributions. The exposed doses to the patient per one time scanning with coronary artery CT angiography were $71.316{\pm}4.316mGy$ in 16-MDCT as the absorbed dose based on the heart and $115.26{\pm}1.59mGy$ in 64-MDCT. The effective doses were 7.41 mSv and 12.11 mSv in 16 and 64-MDCT, respectively. Taking into account the results of brain CT with 2.8 mSv that has comparatively large scanning length and size, facial CT 0.8 mSv, chest CT 5.7 mSv, pelvic CT 7.2 mSv, and abdominal and pelvic CT 14.4 mSv, it is very high considering the scanning length of 13 cm limited to the heart for the scanning range.

Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer (전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가)

  • Heo, Kwangmyoung;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.449-457
    • /
    • 2015
  • In this study, to evaluate the usefulness of the treatment plan of tomotherapy and volumetric modulated arc therapy (VMAT) in the radiotherapy for prostate cancer, the absorbed dose, dose volume histogram (DVH), treatment efficiency, and the results of dose verification accuracy using MapCHECK2 were compared and analyzed. Of the prostate cancer patients who underwent tomotherapy treatment in the Radiologic Oncology of H University Hospital between July 2014 and December 2014, 12 patients were randomly selected. As a result of analyzing the absorbed dose and DVH, both radiologic treatment plans showed slight differences in the treatment of the cancer tissues and the bladder, but the difference was in the error range of -5% to +3%, and did not exceed the side effect guideline or the tolerance dose limit. VMAT showed higher treatment efficiency than tomotherapy with a 2.5 times shorter treatment time and a 10.3 times less monitor unit (MU). Both showed 95% or higher dose accuracy satisfying the standard. VMAT showed 2.3% higher efficiency than tomotherapy. In both tomotherapy and VMAT, appropriate doses were absorbed for cancer tissues, and did not exceed the tolerance dose for normal tissues showing no significant difference in dose distribution. However, considering the shorter treatment time, lower total MU, and better treatment efficiency and dose verification accuracy, VMAT may be more useful than tomotherapy in cancer treatments.

Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation (저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • This study offered a new method to calculate absorbed dose of actual patients through Monte Carlo Simulation by using the linkage of Geant4 and DICOM, and, the experimental value of absorbed dose at the center and Geant 4 simulation result according to the depth of PMMA mock phantom were compared by using MOSEF in order to verify Geant4 calculation code. In the area where there was no air space between the irregular gap due to incomplete compression of PMMA slab, the differences were $0.46{\pm}4.69$ percent and $-0.75{\pm}5.19$percent in $15{\times}15cm^2$ and $20{\times}20cm^2$ respectively. Excluding the error due to incomplete compression of PMMA mock phantom, the calculation values of the Monte Carlo simulation by linkage of Geant4 and DICOM was the same.

Evaluation of the Fetal Dose during Prophylactic Placement of Internal Iliac Artery Balloon Occlusion Catheters in Placenta Accreta (유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가)

  • Kim, Dong-Sik;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.313-321
    • /
    • 2016
  • Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38~8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49~18.27 mGy.