• Title/Summary/Keyword: 흡수법

Search Result 1,592, Processing Time 0.034 seconds

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

Structure/Permeability Relationships of Polyimides for Oxygen and Nitrogen (Polyimide의 화학구조와 산소/질소의 투과특성)

  • 남세종
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.09a
    • /
    • pp.23-38
    • /
    • 1995
  • 고분자막에 의한 기체분리는 심냉분리법, 흡수법, 흡착법등에 비하여 에너지가 절약되며 장치가 간결하고 운전비용이 낮은 이점 때문에 여러가지 기체혼합물에 대하여 여러가지 목적으로 응용되기에 이르렀다. O$_{2}$/N$_{2}$ 분리막으로 요구되는 기본특성은 1) 높은 O$_{2}$ 투과성 2) 높은 O$_{2}$ 선택성 3) 막 형성에 충분한 기계적 강도 4) 열, 화학적으로 안정성이 있어야 한다. 그런데 투과계수 P$_{O_(2)}$와 투과선택도 P$_{O_(2)}$/P$_{N_(2)}$ 관계 Fig.2 에서 보는 바와 샅이 대체로 투과선택성은 상반관계에 있어서 polyimide는 높은 선택성을 나타내고 기계적 강도가 좋고 높은 열에 대하여 안정하기 때문에 일단 막재료로 양호한 조건을 갖추고 있으나 투과계수가 크지 않아 선택도를 크게 감소시키지 않으면서 투과계수를 향성시키려는 노력이 경주되고 있다. 따라서 polyimide의 화학구조와 투과계수, 투과선택도의 관계를 고찰하는 것은 대단히 중요하다. 특히 최근에는 polyimide의 화학구조를 계통적으로 변화 시켜가면서 구조와 투과특성을 고찰한 연구가 많으며, 이러한 연구를 총망라하여 화학구조와 투과특성을 고찰한 훌륭한 총설들이 발표되어왔다. Fig.3에는 지금까지 연구된 중요한 polyimide를 형성하는 dianhydride와 diamine의 구조식을 표시하였으며 이들 구조의 변화에 의하여 기체투과계수와 투과선택도가 어떤 영향을 받는지 고찰하고자 한다.

  • PDF

Analysis of development trends for the $CO_2$ separation and recovery technologies ($CO_2$ 분리회수 기술 동향 분석)

  • 우광제;황재동;정석용;문길호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.153-154
    • /
    • 2001
  • 온실가스 감축 규제에 대응하기 위해 우리나라를 비롯한 많은 국가에서 대량의 $CO_2$ 감축을 목적으로 다양한 기술개발이 추진되고 있다. 온실가스 저감기술을 분류하는 방법으로 에너지 생산/사용에 대한 효율 향상 기술과 발생되는 온실가스를 근본적으로 억제 혹은 발생 온실가스를 효율적으로 처리하는 기술로 크게 분류되고 있다. 우선, 에너지에 대한 기술 중에는 에너지절약기술과 저탄소 에너지 사용(원자력, 신재생에너지, 천연가스)을 위한 대체에너지 및 청정에너지기술이 있으며, 발생된 온실가스 처리에 대한 분리회수 기술로는 흡착법, 흡수법, 막분리법, 막흡수법 등이 연구되고 있다. (중략)

  • PDF

Comparison of Determination Methods for Available-P in Soil of Plastic Film House (시설재배 토양의 유효인산 측정방법 비교)

  • Yang, Won-Seok;Kang, Seong-Soo;Kim, Ki-In;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.3
    • /
    • pp.163-172
    • /
    • 2006
  • Pot experiments were conducted from 1999 to 2001 to compare the different methods of available phosphorus (P) for estimation of biomass and P uptake by tomato and cucumber grown on different soils (25 soils for tomato and 8 soils for cucumber cultivation) collected from plastic film house of Chungbuk area. Supplementary experiment was conducted to estimate the relationship among several extraction methods of available P such as P adsorption, water extractable-P, Lancaster-P, Olsen-P, Bray No 1 and No 2-P, and Mehlich 1 and 3-P for a total of 71 soils that included 33 soils collected for tomato and cucumber cultivation and 38 soils taken from other sites of plastic film house. All the extraction methods of available phosphorus except P adsorption were mutually positive correlated with r ranging from 0.81 to 0.96 while the correlation coefficient between P adsorption and other methods ranged from -0.57 to -0.80. Phosphorus uptake by tomato plant applied with no fertilizer was significantly correlated with the available P extracted by different methods except P adsorption in all the experiments showing positive correlation coefficients from 0.49 to 0.76 in April, 1999, 0.53 to 0.71 in April, 2000, and 0.59 to 0.68 in October, 2000. Consequently relative amount of P uptake by tomato plant for all the experiments also significantly correlated with available P in soils showing correlation coefficients of r=0.64~0.73 (P<0.0000001) in the order of Mehlich 1-P > Mehlich 3-P > Lancaster-P. For tomato, critical concentrations of available P in soils estimated by Cate and Nelson split method were $1700mg\;kg^{-1}$ for Mehlich 3-P, $1,050mg\;kg^{-1}$ for Mehlich 1-P, and $95mg\;kg^{-1}$ for water extractable P. Also P uptake by cucumber plant was significantly correlated with Olsen-P, water extractable P, and Bray No 2-P with r value of 0.62, 0.59, and 0.51, respectively, in soils of no fertilization.

A Method to Determine Amount of Adsorbed Oil in Hair Washing Using Absorption Spectroscopy (흡수 분광법을 이용한 세정 과정에서 흡착된 오일의 평가)

  • Song, Sang-Hun;Kim, Hyun young;Son, Seong Gil
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.2
    • /
    • pp.105-116
    • /
    • 2019
  • Oil adsorption during hair or body washing is responsible for the hair conditioning. In this study, we established a method to extract oil from a substrate, and to determine amount of adsorbed oil upon substrate using a conventional absorption spectroscopy. We controlled the mole fraction of a surfactant in a mixture of anionic and amphoteric surfactants because that it induces the coacervate that regulates amount of adsorbed oil through the alteration of oil viscosity. Based on this, we established the optimized condition for adsorption and extraction for oil. UV absorbance were employed to estimate the amount of adsorbed oil using optical absorbance after extraction via adsorption. The estimation was confirmed by comparing with a mass analysis in HPLC and an adhesive energy in AFM. It has been proved that this method can be applied to all cases of oil adsorption from the results with various cationic polymers and a complex system of the polymers which regulate the oil adsorption.

Integrated Cavity Output Spectroscopy Using an External Cavity Diode Laser for the Density Absorption Measurement of Trace Gases (미량 기체의 밀도 측정을 위한 외부 공진기 반도체 레이저 광학공동 적분 투과 분광법)

  • Ryoo Hoon Chul;Yoo Yong Shin;Lee Jae Yong;Hahn Jae Won
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.24-30
    • /
    • 2006
  • Integrated cavity output spectroscopy(ICOS) is a simple, non-intrusive absorption measurement technique that can detect and quantify trace-level gas species. The spectral absorbance of a gas is quantified from the integrated optical output of the modulated high-finesse cavity containing the sample which is irradiated by a wavelength-swept laser source. We constructed an experimental setup by using a tunable single mode external cavity diode laser operating at the wavelength near 765 nm and a Fabry-Perot cavity with length modulation achieved by a piezoelectric transducer where one of the cavity mirrors sat on. In the experiment performed on minute oxygen gas at the wave-length near 764.5nm, we demonstrated the minimum detectable absorption of $8.45\times10^{-8}cm^{-1}$.

A Dispersive APML using Piecewise Linear Recursive Convolution for FDTD Method (FDTD법을 이용하여 분산매질을 고려하기 위한 PLRC-APML 기법)

  • Lee Jung-Yub;Lee Jeong-Hae;Kang No-Weon;Jung Hyun-Kyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.10 s.89
    • /
    • pp.977-982
    • /
    • 2004
  • In this paper, a dispersive anisotropic perfectly matched layer(APML) is proposed using piecewise linear recursive convolution(PLRC) for finite difference time domain(FDTD) methods. This proposed APML can be utilized for the analysis of a nonlinear dispersive medium as absorbing boundary condition(ABC). The formulation is simple modification to the original AMPL and can be easily implemented. Also it has some advantages of the PLRC approach-fast speed, low memory cost, and easy formulation of multiple pole susceptibility. We applied this APML to 2-D propagation problems in dispersive media such as Debye and Lorentz media The results showed good absorption at boundaries.

Comparison of Absorbing Boundary Conditions and Waveguide Port Boundary Condition for Waveguide Electromagnetic Analysis Using Finite Element Method (유한요소법을 이용한 도파관 전자기 시뮬레이션에 있어 흡수경계조건 및 도파관 포트 경계조건 고찰 및 비교)

  • Mincheol Jo;Woobin Park;Woochan Lee
    • Journal of Internet Computing and Services
    • /
    • v.24 no.2
    • /
    • pp.27-36
    • /
    • 2023
  • Waveguides are transmission lines that guide electromagnetic waves in the desired direction and are utilized in various fields such as medical devices, radar systems, and satellite communications. Computational electromagnetics (CEM) is essential for designing and optimizing waveguides. The finite element method (FEM), which is one of the numerical analysis techniques, is efficient in solving closed problems such as waveguides. In order to apply FEM for waveguide analysis, boundary conditions that truncate the computational domain are required. This paper performs electromagnetic simulations using absorbing boundary conditions (ABC) and waveguide port boundary conditions (WPBC) in 2/D and 3/D waveguides using the finite element method and compared their performances. The accuracy of the analysis was verified by comparing the results with HFSS, a representative commercial electromagnetic simulation software. Simulation results confirm that applying WPBC allows for smaller analysis domains than ABC.

Analysis of $Cr_2O_7^{-2}/MnO_4^{-}$ Mixtures by an Absorption Spectrometry Coupled with Flow Injection Analysis(FIA) (흐름주입분석기법에 접목된 흡수분광분석법에 의한 $Cr_2O_7^{-2}/MnO_4^{-}$혼합물의 분석)

  • Hwang, Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.3
    • /
    • pp.212-219
    • /
    • 2000
  • An absorption spectrometry coupled with flow injection analysis has been developed and tested for the analysis of the Cr$_2O_7^{2-}$/Nn$O_4^-$ mixtures. Even though one has to inject the sample twice into the FIA system and the process of the sample treatment is required to completely destroy the Mn$O_4^-$ ion for the analysis of the Cr$_2O_7^{2-}$ ion, the new method has definite advantages over the current method. It utilizes only a single analytical wavelength (570 nm) and enables one to construct calibration curves which accurately follow the Beer's law over wide ranges of analytical concentrations of both ions ($2.0{\times}10^{-6}$M∼$8.0{\times}10^{-3}$M for Cr$_2O_7^{2-}$ ion, $2.0{\times}10^{-6}$M∼$4.0{\times}10^{-3}$M for MnO4- ion).

  • PDF

Absorption Spectra of a Methylene blue-Tetraphenylborate Ion Pair (Methylene Blue-Tetraphenylborate 이온쌍의 흡수스펙트럼)

  • Hyung-Soo Song;Young Joon Park;Kang-Jin Kim
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.6
    • /
    • pp.355-360
    • /
    • 1984
  • A new absorption spectrum observed from dilute aqueous solutions of methylene blue$(MB^+)$ and tetraphenylborate(TPB$^-$) ions was investigated by spectrophotometry. The species responsible for the spectrum can be a charge-transfer complex formed between the two, univalent, and poorly hydrated ions in order to minimize the disturbance to the water structure. However, as the absorption band of MB$^+$ is split into two bands with exciton splitting of about 2,000 cm$^{-1}$, the formation of double ion-pair, (MB-TPB)$_2$ appears to be more favorable than the charge transfer complex.

  • PDF