• Title/Summary/Keyword: 휨강도 감소

Search Result 408, Processing Time 0.031 seconds

A Study on the Flexural Behaviors of RC Slabs of Widened Bridges (확폭교량 RC 상판의 휨거동에 관한 연구)

  • 홍순길;장동일
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.3
    • /
    • pp.152-161
    • /
    • 1994
  • Most widened bridges have been constructed by the joining-construction method that makes new and existing bridges structurally a single structure. Since the joining-construction method has several problems in design and construction viewpoint, this study is conducted in order to investigate the structural behaviors of RC slabs, which are widened and influenced by traffic-induced vibration of existing bridge during placing and curing of new concrete, with the prototype flexural strength test and FEM analysis. It was found that cracks are generated in construction joint at low applied load and that stress concentration at the joints and slips between steel bar and concrete are occured. But, the decreasing of load carrying capacity is negligible according to the traffic-induced vibration as well as the difference of construction method.

An Experimental Study on Flexural Strength of Deep Corrugated Steel Plate Composite Members by Steel Grade and Reinforcement Method (강종 및 보강방법에 따른 대골형 파형강판 합성부재의 휨성능에 관한 실험적 연구)

  • Kim, Yongjae;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.1-12
    • /
    • 2017
  • In this study, It was purpose to provide preliminary data for extension of the applicability of deep corrugated steel plate composite members by steel grade and shear reinforcement method. From the result of flexural test on deep corrugated plates composite members using GR40 and SS590, positive moment capacity was increased about 28% by SS590 steel. But to change steel grade was proved to have insignificant effects for increasement of negative moment capacity. In the moment test result of same overlapping length, Increasement rate of positive and negative moment capacity was not significantly improved by increasing the number of bolt. It was estimated to be due to the characteristics of bolt connection such as distance between centers of bolts, edge distance of bolt. In the test result on the spacing of shear reinforcement, positive moment capacity was increased and deformation of negative moment was reduced as the distance decrease. In the test result on the shape of shear reinforcement, positive and negative moment resistance was increased about 2% ~ 7% by U shaped shear reinforcement. In conclusion It was estimated that moment capacity of deep corrugated steel plate composite members are depend on steel grade of deep corrugated steel plate, spacing of shear reinforcement and reinforcing bar.

Effect of Partial Prestressing Ratio and Effective Prestress on the Flexural Behavior of Prestressed Lightweight Concrete Beams (프리스트레스트 경량 콘크리트 보의 휨 거동에 대한 부분 프리스트레싱비와 유효 프리스트레스의 영향)

  • Yang, Keun-Hyeok;Moon, Ju-Hyun;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present investigation evaluates the flexural behavior of pre-tensioned lightweight concrete beams under two-point symmetrical concentrated loads according to the variation of the partial prestressing ratio and the effective prestress of prestressing strands. The designed compressive strength of the lightweight concrete with a dry density of 1,770 $kg/m^3$ was 35 MPa. The deformed bar with a yield strength of 383 MPa and three-wire mono-strands with tensile strength of 2,040 MPa were used for longitudinal tensile reinforcement and prestressing steel reinforcement, respectively. According to the test results, the flexural capacity of pre-tensioned lightweight concrete beams increased with the increase of the partial prestressing ratio and was marginally influenced by the effective prestress of strands. With the same reinforcing index, the normalized flexural capacity of pre-tensioned lightweight concrete beams was similar to that of pre-tensioned normal-weight concrete beams tested by Harajli and Naaman and Bennett. On the other hand, the displacement ductility ratio of pre-tensioned lightweight concrete beams increased with the decrease of the partial prestressing ratio and with the increase of the effective prestress of strands. The load-displacement relationship of pre-tensioned lightweight concrete beam specimens can be suitably predicted by the developed non-linear two-dimensional analysis procedure. In addition, the flexural cracking moment and flexural capacity of pre-tensioned lightweight concrete beams can be conservatively evaluated using the elasticity theorem and the approach specified in ACI 318-08, respectively.

Comparisons of Numerical Analyses considering the Effects of Shear Strength Degradation For Nonseismic Designed RC Frame (비내진 설계된 RC 골조에 대한 전단강도 감소 효과를 고려한 수치해석의 비교)

  • Lee, Young-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.1-8
    • /
    • 2006
  • Nonseismic designed RC frame have a possibility of shear failure because of deficiencies of reinforcing details. To model the shear failure in numerical analysis, shear strength degradation models which Include Moehle's and ATC 40 are compared and applied to push-over analysis. For numerical analysis, three storied building frame is selected and designed according to Korean Concrete Design Code(2003). As results, It is shown that Moehle's shear strength degradation model estimates the shear strength lower than NZSEE model and has less variation than ATC 40 model and all the shear strengths of models are greater than the nominal shear strength of ACI 318. Also, from the numerical analysis, it is pointed out that there may be great difference in lateral drift capacity if a different shear strength model is used. And the capacity can be severely underestimated if the restraining model of plastic rotation of ATC 40 is used, compared to the use of shear spring model for shear degradation.

An Experimental Study on Tensile Properties of Steel Fiber-Reinforced Ultra High Strength Concrete (강섬유 보강 초고강도 콘크리트의 인장 특성 실험 연구)

  • Yang, In-Hwan;Park, Ji-Hun;Lee, Jae-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.279-286
    • /
    • 2019
  • In this study, an experimental study on the tensile properties of steel fiber-reinforced ultra high strength concrete(UHSC) with a standard compressive strength of 180MPa was performed. Steel fibers with a volume ratio of 1% were mixed to prepare direct tensile strength specimens and prism specimens for the three-point bending test. The fabricated specimens were set up in the middle section of the specimen to induce cracks, and the test was carried out according to each evaluation method. First, the stress-strain curves were analyzed by performing direct tensile strength tests to investigate the behavior characteristics of concrete after cracking. In addition, the load-CMOD curve was obtained through the three-point bending test, and the inverse analysis was performed to evaluate the stress-strain curve. Tensile behavior characteristics of the direct tensile test and the three-point bending test of the indirect test were similar. In addition, the tensile stress-strain curve modeling presented in the SC structural design guidelines was performed, and the comparative analysis of the measured and predicted values was performed. When the material reduction factor of 1.0 was applied, the predicted value was similar to the measured value up to the strain of 0.02, but when the material reduction factor of 0.8 was applied, the predicted value was close to the lower limit of the measured value. In addition, when the strain was greater than 0.02, the predicted value by SC structural design guideline to underestimated the measured value.

Comparison of Flexural Tensile Strength according to the Presence of Notch and Fiber Content in Ultra High Performance Cementitious Composites (노치 유무와 섬유혼입률에 따른 UHPCC의 휨인장강도 비교)

  • Kang, Su-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.525-533
    • /
    • 2012
  • In this study, bending tests were performed on beam specimens made of UHPCC with the fiber content range of 0~5 vol% to investigate the contribution of fiber content to first cracking strength and flexural tensile strength. Also, four-point bending tests for unnotched beam as well as three-point bending test for notched beam were performed to estimate the effect of the presence of notch on the strengths. The experiment result showed that the increase in fiber content made linear improvement in the flexural tensile strength; whereas first cracking strength was enhanced only when at least 1 vol% of fibers was incorporated. Comparison of the bending test results with and without notch showed that the notch effect varied with the fiber content. The increase in fiber content diminished the effect of stress concentration on the notch tip, reducing the difference in the strengths. With much higher fiber content, the effect of stress concentration almost disappeared and the defection on cracking plane or the size effect dominated the strengths, consequently resulting in higher strengths in the notched beams than the unnotched ones.

Studies on Prediction about Behavior of Wood Beam under Standard Fire Condition (표준화염(標準火焰) 노출시(露出時) 목재(木材) 보의 거동(擧動) 예측(豫測)에 관(關)한 연구(硏究))

  • Kim, Lee-Gun;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.10-17
    • /
    • 1995
  • 본 연구는 화염에 노출된 목재 부재의 거동에 관련된 자료를 얻기 위해 수행되었다. 목재 보에 대한 현행 내화 모델들은 외곽부 섬유의 MOE나 휨강도의 감소, 그리고 화염노출의 계속으로 인한 단면의 감소 등에 기초하고 있다. 하지만 이런 모델들은 정확한 거동 예측이 힘들다. 따라서 목재 보의 거동을 정확히 예측하기 위해 본 연구에서는 변형 단면을 이용한 내화거동 모델을 개발하고자 하였다. 이 변형 단면모델을 개발하기 위하여 온도분포 온도와 목재의 물리적 성질간의 상관관계를 이용하였다. 본 연구를 통해 온도와 목재의 휨성질간의 정확한 관계가 제공되기만 한다면 본 방법이 화염에 노출된 목재 보의 변형을 잘 예측할 수 있음을 알 수 있었다.

  • PDF

Properties of Boards Prepared From Woody of Broussonetia Kazinoki Sieb. (닥나무 목질부로 제조된 보드의 성질(I))

  • Oh, Seung Won;Park, Seong Cheol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.216-221
    • /
    • 2009
  • This study was investigated the properties of boards prepared from woody of Broussonetia Kazinoki differed in density of board and mixed quantity of powdered phenolic resin. Water absorption decreased as the density of boards and resin content increased, but bending strength and brinell hardness increased as the density of board and the quantity of resin added increased. Thickness swelling increased as the density of boards went up, and that, in contrary, decreased as the quantity of resin added to the boards.

Effect of Waste Glass Wool on Mechanical Properties of Concrete (폐글라스울이 콘크리트의 역학적 특성에 미치는 영향)

  • Kim, Jeong-Tae;Choi, Woo-Hyuk;Chung, Chul-Woo;Lee, Jae-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • Glass wool is a material that has been used as a heat insulator in various fields including construction industry. Since it is a nonflammable material, it does not generate toxic gases on fire, and thus public agencies recommend using glass wool as a heat insulator instead of other organic materials. However, repeated drying and wetting cycles can deteriorate thermal property of glass wool due to the shrinkage and reduction in pore size. For this reason, it needs to be replaced periodically, and waste materials are generated. This research aims to utilize waste glass wool as additives for increasing mechanical properties of concrete. According to the experimental results, it was found that glass wool has weak pozzolanic activity, and beneficial effect on both compressive and flexural strength. The optimum amount found in this experimental work was 0.5% volumetric addition to the concrete.

An Analytical Study for Structural Behaviors of Unbonded Precast Rectangular Hollow Section Concrete Piers (비부착 프리캐스트 중공 사각 단면 교각의 구조거동에 관한 해석적 연구)

  • Choi, Seung-Won;Kim, Ick-Hyun;Cho, Jae-Yeo;Chang, Sung-Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.61-69
    • /
    • 2010
  • Unbonded precast concrete piers have better seismic performances than conventional reinforced concrete piers. In this research, seismic performances of unbonded precast prestressed concrete piers are analyzed using OpenSEES. Main parameters of analysis are concrete strength, jacking force ratio, ratio of tendon, and size of precast segment. In results, as the ratio of tendon and jacking force ratio increase, the flexural strength increases at softening state and ultimate state. Concrete strength and size of precast segment are negligible. But initial jacking force ratio leads to early yielding of prestressing tendon. Since compressive strain in core concrete is much less than ultimate strain, it can be expected that the amount of transverse steel reinforcement is to be reduced in comparison with conventional reinforced concrete column.