DOI QR코드

DOI QR Code

An Experimental Study on Flexural Strength of Deep Corrugated Steel Plate Composite Members by Steel Grade and Reinforcement Method

강종 및 보강방법에 따른 대골형 파형강판 합성부재의 휨성능에 관한 실험적 연구

  • 김용재 (강원대학교 토목공학과) ;
  • 오홍섭 (경남과학기술대학교 토목공학과)
  • Received : 2016.09.21
  • Accepted : 2017.01.03
  • Published : 2017.03.01

Abstract

In this study, It was purpose to provide preliminary data for extension of the applicability of deep corrugated steel plate composite members by steel grade and shear reinforcement method. From the result of flexural test on deep corrugated plates composite members using GR40 and SS590, positive moment capacity was increased about 28% by SS590 steel. But to change steel grade was proved to have insignificant effects for increasement of negative moment capacity. In the moment test result of same overlapping length, Increasement rate of positive and negative moment capacity was not significantly improved by increasing the number of bolt. It was estimated to be due to the characteristics of bolt connection such as distance between centers of bolts, edge distance of bolt. In the test result on the spacing of shear reinforcement, positive moment capacity was increased and deformation of negative moment was reduced as the distance decrease. In the test result on the shape of shear reinforcement, positive and negative moment resistance was increased about 2% ~ 7% by U shaped shear reinforcement. In conclusion It was estimated that moment capacity of deep corrugated steel plate composite members are depend on steel grade of deep corrugated steel plate, spacing of shear reinforcement and reinforcing bar.

본 연구에서는 대골형 파형강판 합성부재의 구성요소를 고강도 재료로 대체하고 이음방법, 전단보강방법 등 단면구성방법에 따른 단위부재의 휨거동을 분석하여 대골형 파형강판 합성부재 구조물의 장대화 및 적용범위확대를 위한 기초자료를 제시하고자 하였다. GR40과 SS590 강재를 적용한 합성구조체의 휨실험 결과, SS590 파형강판을 적용한 경우 정모멘트 하중저항성능은 약 28%가 증가되는 것으로 확인되었으나 부모멘트 저항성능은 미미한 것으로 확인되었다. 볼트의 개수를 증가시킨 파형강판 이음방법의 정모멘트 및 부모멘트 저항성능증가율은 높지 않은 것으로 확인되었다. 이는 고강도 재료에 따른 볼트의 접합 특성(볼트중심에서 연단까지의 거리, 볼트중심간 간격 등)이 거동에 영향을 미쳤기 때문인 것으로 추정된다. 전단보강재 간격별 휨실험 결과, 보강재 간격이 감소할수록 정모멘트에 대한 하중저항성능, 부모멘트에 대한 변위저항성능이 향상되는 것으로 확인되었다. 전단보강재 형상별 휨실험결과, U형 보강재 적용에 따른 정 부모멘트 저항성능 증가율은 약 2%~7% 로 낮았다. 따라서 대골형 파형강판 합성부재의 휨성능증가에는 파형강판의 강종, 전단보강재 간격, 보강철근의 특성이 주요한 영향을 미치는 것으로 판단된다.

Keywords

References

  1. American Association of State Highway and Transportation Officials. (2010), AASHTO LRFD Bridge Design Specifications, 269-271.
  2. Canadian Standards Association. (2006), Canadian Highway Bridge Design Code, 12.37-12.39.
  3. Choi, Y. J., Lee, J. W., Shin, C. H., and Lee, H. E. (2006), A Study on the Geometric Parameters that Influence the Trapezoidally Corrugated Webs Under Partial Edge Loading, Journal of Korean Society of Steel Construction, KSSC, 18(1), 81-91.
  4. Duncan, J. M. (1973), Behaviour and Design of Long-Span Metal Culvert Structures, ASCE Journal of Geotechnical Division, 105(GT3), 399-417
  5. Heo, C. I. (2010), The Bond Effect Areas of Tension-Bar in Reinforced Concrete Flexure member, Catholic Kwandong University, Gangneung, 3-5.
  6. Hwang, W. S., Kang, S. P., and Wi, Y. M. (2004), Strength and Stress Distribution Behavior for the Connections of Corrugated Steel Plates, Journal of Korean Society of Steel Construction, KSSC, 16(3), 365-375.
  7. Jang, J. M. (2014), A Study on Flexural Strength for Deep Corrugated Steel Plate of Reinforcement Type, Myungji University, Seoul, 74-75.
  8. Kang, S. P. (2004), Evaluation of Limitary Edge Lap and Bolt Hole Spacing for the Corrugated Plate, Inha University, Incheon, 4-6.
  9. Kim, Y. S. (2008), Structural Behavior Analysis of CBS-RIB Structures using Numerical Modeling, Hanyang University, Seoul,1-3.
  10. Lee, K. M. (2003), A Study on Flexural Strength for Deep Corrugated Steel Plate, Seoul National University of Technology, Seoul, 1-2.
  11. McCavour, T. C., Byrne, P. M., and Morrison, T. D. (1998), Long-Span Reinforced Steel Box Culverts, Transportation Research Record No. 1624, TRB National Research Council, Paper No. 98-0591, 184-195.
  12. Na, H. S., Choi, D. H. and Yoo, H. (2011), Determination of Optimal Section for Corrugated Steel Plates, Journal of the Korean Geo-Environmental Society, Korean Geo-Environmental Society, 12(3), 5-12.
  13. Yoon, H. D. (2003), Evaluation of Member Forces in Encased-concrete Corrugated Steel Plate Structures during Construction Stage, Hanyang University, Seoul,1-3.