• Title/Summary/Keyword: 후 분사

Search Result 269, Processing Time 0.028 seconds

Visualization of Transient Ignition Flow-field in a 50 N Scale N2O/C2H5OH Thruster (50 N급 아산화질소/에탄올 추력기의 점화 과도 유동장 가시화)

  • Kim, Dohun;Park, Jaehyeon;Yu, Myunggon;Lee, Kyungeun;Koo, Jaye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.6
    • /
    • pp.11-18
    • /
    • 2014
  • The combustion flowfield at the near-injector region of a 50 N scale $N_2O/C_2H_5OH$ thruster was visualized using shadowgraph technique. The explosive ignition was occurred at the design spray condition, and the expanding combustion gas quenched the flame immediately. Approximately after 83 ms from the initial ignition, the propellant spray was re-ignited, and the flame was stabilized after 23 ms elapsed. In the increased oxidizer flow rate condition, the transient pressure at the moment of ignition was smoother than explosive ignition, and the blow down phenomenon was not appeared in the same operating sequence. In addition, the flame was stabilized within 17 ms, and it is caused by improved propellants mixing before ignition.

Evaluation of Adhesion Property of Epoxy Adhesive with Different Surface Roughness of GFRC (유리섬유강화 복합재료의 표면거칠기에 따른 에폭시 접착제의 접착강도 평가)

  • Kim, Jong-Hyun;Shin, Pyeong-Su;Lee, Sang-Il;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Adhesion property of epoxy adhesive was evaluated with different surface roughness of glass fiber reinforced composite (GFRC) and optimized condition of surface roughness was confirmed. Different sizes of alumina (Al2O3) particles were blasted to GFRC to control surface roughness of GFRC using sand blasting method. The surface roughness was measured and quantified via surface roughness tester. Contact angle was measured using four types of different solvents. Surface energies and work of adhesion between epoxy adhesive and GFRCs were calculated with different surface roughness of GFRC. Adhesion property between epoxy adhesive and GFRCs was evaluated using single lap shear test and adhesion property increased with surface roughness of GFRC. The fracture surface of GFRCs was observed to evaluate adhesion property. Finally, the optimized roughness condition of GFRCs was confirmed.

Optimal Design of Fuel-Rich Gas Generator for Liquid Rocket Engine (액체로켓의 농후 가스발생기 최적설계)

  • Kwon, Sun-Tak;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.5
    • /
    • pp.91-96
    • /
    • 2004
  • An optimal design of the gas generator for Liquid Rocket Engine (LRE) was conducted. A fuel-rich gas generator in open cycle turbopump system was designed for 10ton in thrust with RP-1/LOx propellant. The optimal design was done for maximizing specific impulse of thrust chamber with constraints of combustion temperature and for matching the power requirement of turbopump system. Design variables are total mass flow rate to gas generator, O/F ratio in gas generator, turbine injection angle, partial admission ratio, and turbine rotational speed. Results of optimal design provide length, diameter, and contraction ratio of gas generator. And the operational condition predicted by design code with resulting configuration was found to maximize the objective function and to meet the design constraints. The results of optimal design will be tested and verified with combustion experiments.

Spherodization of Granuled Cr2O3 Fine Ceramic Powder by Plasma Spray (플라즈마 분사 처리에 의한 Cr2O3 조립분말의 구상화에 대한 연구)

  • Lee, Dong Won;Lee, Hak Sung;Yu, Ji-Hun;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.25 no.6
    • /
    • pp.92-97
    • /
    • 2016
  • Spray dried $Cr_2O_3$ powder having an agglomerated structure of particles was twice treated into a plasma flame to increase its apparent density. The powder subjected to the first densification treatment did not show the entirely melted state keeping inner particle hollows, and it was fully melted after the second processing only. The powder size as a result of the second treatment decreased, and the apparent density as well as flowability were increased due to melting and surface smoothing effects. But a part of particles after the second densified treatment showed the hollow structure, especially those which were above $30{\mu}m$ in size. This densification behavior of the powder has been qualitatively discussed in terms of the thermal conductivity and inner gas pressure within aggregates exposed to the plasma flame.

Colour Removal from Dyestuff Wastewater by Micro Bubbles Flotation Process (마이크로 버블 부상 공정에 의한 염료폐수의 색도 제거)

  • Kim, Myeng-Joo;Han, Sien-Ho
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.606-612
    • /
    • 2022
  • The purpose of this study is to convert hydrophobic dyestuff to hydrophilic dyestuff by reacting cationic collector with anionic dyestuff and reaction anionic collector with cationic dyestuff. The removal of colors from aqueous solutions and/or dispersions has been studied by dispersed-air flotation in a batch column. In this studies used generated micro bubble by ceramic gas diffuser having micro pore size for air flotation process. In this study, a ceramic gas diffuser with micro pore size was used to generate micro bubbles for the air flotation process. Two colours were used for the experiments: Basic Yellow 1 (cationic dyestuff) and Direct Orange 10 (anionic dyestuff). All two were effectively removed by flotation within 8 mins. Sodium dodecyl sulfate, sodium oleate (an anionic collector), and amines (a cationic collector) were found to be effective as collectors in the removal of color, which was found to be related to the pH of the solution and the amount of collector added to it, with high collector dosages causing the process to become pH-independent.

Step-by-step Tests for Continuous Thrust Control Hot-firing Test (연속 추력제어 연소시험을 위한 단계별 시험들)

  • Cheolwoong Kang;Shinwoo Lee;Sunwoo Han;Kangyeong Lee ;Hadong Jung;Dongwoo Choi;Kyubok Ahn
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.58-67
    • /
    • 2023
  • Results of dry-run tests, cold-flow tests, and hot-firing tests performed to throttle a methane engine uni-element thrust chamber are covered in the paper. After installing flow control valves on the oxidizer and fuel supply lines of the methane engine combustion test facility, a number of dry-run tests were repeated so that the valves could reach set strokes quickly and stably. Then, cold-flow tests using liquid nitrogen and gaseous nitrogen were conducted to confirm the stable supply of the simulated propellants according to the valve control. Finally, using liquid oxygen and gaseous methane, hot-firing tests for fixed and continuous thrust control of 50% to 10% of the nominal thrust were successfully performed.

Development of Glass Fiber Composite Material to Extend the Life of Fly Ash Transport Pipe: Wear Test (비회 운송관의 수명연장을 위한 유리섬유 복합재의 개발: 내마모성 평가)

  • Jeong, Gyu-Sang;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.15 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • In this study, a fiber reinforced plastic (FRP) pipe with superior wear resistance was developed to replace the fly ash pipe of cast iron. Wear test was performed with various combinations of SiC filler and resin materials of unsaturated polyester, vinylester, epoxy, and phenol. Test results of ASTM D4060 showed the optimal combinations of resin, filler size, and resin/filler ratios. Test results of comparison between FRP and cast iron showed the possibility to replace cast iron pipe with the FRP pipe. Field test executed to compare the wear resistance between cast iron pipe and developed FRP pipe showed the superiority of the FRP pipe.

Hydraulic mechanism for rill development by interaction between rainfall and inflow water (강우와 유입수 상호작용에 의한 세류발달 수리학적 메커니즘)

  • Shin, Seung Sook;Park, Sang Deog;Sim, Young Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.229-229
    • /
    • 2021
  • 최근 이상기상으로 국지성 집중호우가 빈번하게 발생함에 따라 토사유출에 의해 피해가 증가하고 있다. 급경사 사면을 갖는 교란산지와 개발지의 경사면은 토양침식 위험에 노출되어 있다. 특히 지표유출수의 집중흐름에 의한 세류발달은 세류간침식에 비해 많은 토양침식과 토사유출을 발생시킨다. 이러한 급경사 사면에서의 세류발달에 대한 수리학적 메터니즘과 한계조건을 파악하고자 강우와 유입수 모의를 통한 토양침식 실험을 수행하였다. 강우와 유입수의 상호작용에 의한 세류발달의 특성과 토사유출량 증가를 파악하고자, 강우량의 증가와 유입수 유무에 따른 실험이 이루어졌다. 강우강도의 범위는 100~140mm/hr이고, 유입수는 170ml/s 이였다. 유입수량은 합리식으로 계산하였으며, 토양상자 상단에서 균등분사식으로 유입되었다. 세류발달의 수리학적 특성치를 취득하기 파악하기 위해, 염료주입 지표수 거동에 대한 동영상을 판독하였다. 세류발달은 유입수가 없는 경우 3분 이내 그리고 유입수가 있는 경우 30초 이내에 발생하였다. 토양상자내의 평균 유속범위는 7.83~29.27 cm/s 이였다. 실험에서 발달된 세류는 15분경과 후부터 평형상태를 유지하였다. 경사실험조건별로 세류 차수분석을 위해 각 세류의 최대길이, 폭, 넓이를 측정한 결과 세류의 차수는 강우만 있는 경우 1~2차로 발달하였으며, 유입수가 있을 때는 2~3차로 발달하였다. 지표유출이 증가하면서 세류발달의 개수는 줄었지만 규모는 더 크게 나타났다. 세류가 발달하는 시점의 한계유속은 10~20cm/s 범위인 것으로 파악되었다. 지표유출이 증가하면서 세류의 발달도 더 심화되지만, 동일한 강우에 일정시간동안 노출되면서 세류는 평형상태가 되어 더 이상 침식이 활발하게 진행되지는 않았다. 유입수가 있는 조건에서 수량은 약 2배가 증가하였지만, 토사유출량은 세류확장에 의해 약 4배가 증가하는 것으로 나타났다.

  • PDF

A Study on the Facility for Domestic Waste Problems of high Temperatured Combustion and the Alteration of heating surface (폐기물소각로의 고온 연소에 따른 문제와 연소실 전열면 변경에 대한 연구)

  • Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.60-67
    • /
    • 2010
  • Korea's large-scale incinerating facilities of domestic waste were built in the late 1980's. It was found that most of the incinerators were designed during the period and even the ones constructed afterwards have been built without any changes or modifications. However, the nature of waste fed into incinerators is undergoing a radical change due to government policies on waste collection, which is upheld by a research into changes in the heating value of domestic wastes. As a result, refractories and stokers are being damaged in many of the facilities due to overheating. On the other hand, the formation of clinkers on boilers' heating surface, which curbs he at transfer, results in problems such as a fall in used heating value and a rise in the temperature of combustion chambers. Methods are being deployed to resolve the problems-such as spraying water on piles of waste, incinerating food waste by mixing together what has been separately collected, spraying water on combustion chambers, etc. Such actions are not a fundamental solution, nor redesigning and rebuilding incineration facilities is cost-effective. This research seeks to develop a fundamental solution to address the situation.

Effect of Exogenous Application of Salicylic Acid or Nitric Oxide on Chilling Tolerance and Disease Resistant in Pepper Seedlings (외생 살리실산과 일산화질소 처리가 고추묘의 저온 내성 및 병 저항성에 미치는 영향)

  • Park, Song-Yi;Kim, Heung-Tae;Oh, Myung-Min
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.329-336
    • /
    • 2014
  • As an abiotic stress, chilling stress is one of the major factors limiting plant growth and increasing susceptibility to pathogens. Therefore, enhancing stress tolerance in plants is an important strategy for their survival under unfavorable environmental conditions. The objective of this study was to determine the effects of the exogenous application of salicylic acid (SA) or nitric oxide (NO) on chilling tolerance in pepper seedlings. Pepper (Capsicum annuum L. 'kidaemanbal') seedlings were grown under normal growing conditions ($20/25^{\circ}C$, 15 hours photoperiod, $145{\pm}5{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, fluorescence lamps) for 23 days after transplanting. The solution (3 mL) of 1 mM SA and 0.3 mM NO with surfactant triton 0.1% were sprayed two times a week, respectively. Right after the completion of chemical application, seedlings were subjected to chilling condition at $4^{\circ}C$ for 6 hours under dark condition and then the seedlings were recovered at the normal growing conditions for 2 days. In order to assess plant tolerance against chilling stress, growth characteristics, chlorophyll fluorescence (Fv/Fm), and membrane permeability were determined after chilling stress imposition. Total phenolic concentration and antioxidant capacity were measured during the whole experimental period. Disease incidence for pepper bacterial spot and wilt was also analyzed. Pepper seedlings treated with SA or NO were maintained similar dry mass ratio, while the value in control increased caused by chilling stress suggesting relatively more water loss in control plants. Electrolyte leakage of pepper seedlings treated with SA or NO was lower than that of control 2 days after chilling treatment. Fv/Fm rapidly decreased after chilling stress in control while the value of SA or NO was maintained about 0.8. SA increased higher total phenolic concentration and antioxidant capacity than NO and control during chemical treatment. In addition, increase in total phenolic concentration was observed after chilling stress in control and NO treatment. SA had an effect on the reduction of bacterial wilt in pepper seedlings. The results from this study revealed that pre-treatment with SA or NO using foliar spray was effective in chilling tolerance and the reduction of disease incidence in pepper seedlings.