• Title/Summary/Keyword: 후드

Search Result 181, Processing Time 0.025 seconds

Experimental Study on the Slit Cover Hood for Reducing the Micro Pressure Waves in High-speed Train-tunnel Interfaces (고속철도에서 슬릿커버후드의 터널 미기압파 저감성능에 관한 연구(II))

  • Kim, Dong-Hyeon;Shin, Min-Ho;Han, Myeong Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.3-11
    • /
    • 2000
  • Purpose of this paper is to investigate the hood configuration at a tunnel entrance to reduce the micro pressure wave that is generated according to train speed. Two configurations were examined for the tunnel of 0.5 km in length. The experimental results show that a slit cover hood installed at the entrance of the tunnel reduces the maximum micro pressure wave by 41.2%, and the configuration with a slit cover hood installed at the entrance and the $45^{\circ}$ slanted portal at the exit of the tunnel suppress the pressure wave by 47.7%.

  • PDF

A Study on the Hood Performance Improvement of Pickling Tank using CFD (전산유체역학을 이용한 산세조 후드 성능 개선에 관한 연구)

  • Jung, Yu-Jin;Park, Ki-Woo;Shon, Byung-Hyun;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.593-601
    • /
    • 2014
  • In this study, we investigated the methods of improving the capturing ability of acid fume by assessing the performance of slot-type external hood installed on both sides of an open surface tank for acid washing process. A field survey and the results of computational fluid dynamics revealed that capturing performance of existing hoods is very poor. To solve such problem, 'push-pull hood' that pushes from one side of an open surface tank and pulls on the other side was suggested. The initial prediction was that if a push-pull hood is used, the acid fume of an acid-washing tank surface could be moved towards the hood through the push flow. However, this study has confirmed that if the push flow velocity becomes too high, it could spread to other areas due to flooding from the hood. Therefore, if the push air supply is maintained at around 25 $m^3/min$(push 10 m/s), proper control flow is formed on the surface of a tank and acid fume that stayed at the upper part of the tank is smoothly captured toward the hood, significantly enhancing the capturing performance.

A study on the optimized hood design in melting process of casting facilities using CFD (전산유체역학을 이용한 주물 제조 사업장 용해 공정의 최적 후드 설계에 관한 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Jung, Jong-Hyeon;Lim, Ki-Hyuk;Kim, Jin-Uk;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.269-272
    • /
    • 2011
  • 주물 사업장의 용해 공정인 장입과 출탕 작업, 첨가제 투입 과정에서 많은 분진이 발생한다. 실제 주물 사업장에서 사용되는 후드 형태는 매우 다양하며 구조적인 문제점으로 인해 효과적인 배기가 어려운 실정이다. 본 연구를 통해 실제 사업장에 전기로의 다양한 공정 형태에 대한 대응이 가장 우수한 직인식 후드 방식을 제시하고, 전산유체역학(CFD : Computational Fluid Dynamics)을 이용한 오염물질 거동 예측 기법을 활용하여 직인식 후드의 적정 배기량을 산정하여 현장에 제시하였다. 실제 현장에서는 본 개념 설계 결과를 바탕으로 용해 공정에 $400m^3/min$의 배기량을 갖는 직인식 후드를 설치한 결과, 매우 만족스러운 분진 제어 효율을 확인할 수 있었다.

  • PDF

A study on the Urban Growth Model of Gimhae City Using Cellular Automata (셀룰라 오토마타를 이용한 김해시의 도시성장모형에 관한 연구 - 1987~2001년을 중심으로 -)

  • Lee, Sung Ho;Yun, Jeong Mi;Seo, Kyung Chon;Nam, Kwang Woo;Park, Sang Chul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.3
    • /
    • pp.118-125
    • /
    • 2004
  • The purpose of this study is to decide an appropriate neighborhood and a transition rule of cellular automata by analyzing the past growth process of urban areas in Gimhae. With cellular automata which can manage the change based on the dynamic model and time, this study analyzes the urban growth of Gimhae from 1987 to 2001. Also, through the simulation of different types for neighborhood and transition rules, we can find the appropriate neighborhood and the transition rule for Gimhae. In conclusion, the forecast of physical urban growth pattern is more accurate under conditions when the number of matrixes for the neighborhood is small, the shape of the neighborhood is rectangular, "${\alpha}$" value, which control the pace of urban growth, is low and the transition possibility ($P_{ij}$) is high.

  • PDF

A Numerical Study on Performance Improvement of Canopy Hood in Melting Process (용해공정의 캐노피 후드 성능 개선에 관한 수치 해석적 연구)

  • Jung, Yu-Jin;Shon, Byung-Hyun;Lee, Sang-Man;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1519-1526
    • /
    • 2013
  • This study reviewed the capturing performance of a canopy hood used in some melting processes of a casting manufacturing factory through a site survey. In addition, this study compared and evaluated the flow field and pressure field for the plans to enhance the hazardous air pollutants collection capacity by using CFD model. The case-2(flange attached + double hood) can be improved in terms of collection performance, but is expected to increase in hood static pressure by about 70% more than the existing structure, so it was shown that its site applicability is not good. It is judged that the shape of case-3(flange attached + double cone attached) is most suitable to improve the suction efficiency. This is because a double cone is installed at the center of the opening to concentrate the flow rate on the edge of the hood and control the hume rising to the center of the hood without a static pressure rise via the slope of the cone.

Improvement of Capturing Velocity in the Fume Hood using Computational Fluid Dynamics(I) - Uniform flow (전산유체역학을 이용한 흄후드 제어유속 개선(I) - 균일류)

  • Jung, Jong-Hyeon;Lee, Sang-Woon;Lee, Sang-Man;Shon, Byung-Hyun;Lee, Jung-Hee;Jung, Yu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.962-969
    • /
    • 2013
  • This study used Computational Fluid Dynamics(CFD) to assess the properties of the air current inflow and the flow velocity distribution in the fume hood. In order to verify the effect of improvement, it was also predicted the characteristics of the flow pattern in case the hood face is structurally improved. The assessment of the capture velocity with the existing fume hood confirmed maximum 23 to 30% difference as compared to the root mean square (RMS). And the hood face showed great difference in flow velocity, with the flow velocity in the upper part is 58 to 68% faster than that in the lower part of the hood. So, as a result of the improvement of the hood designed to maintain a steady exhaust at the hood face (that is, installing a baffle on the inner wall and designing the slot type face), a difference of maximum 7% as compared to RMS appeared while maximum 12% differentiation in flow velocity through sections was predicted, showing mitigation of much of the difference in control velocity as compared to the previous structure.

Numerical analysis for development of vehicle engine room cooling hood (차량 엔진룸 냉각용 후드 개발을 위한 수치해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.92-97
    • /
    • 2018
  • This study deals with the numerical analysis for hood development to improve the cooling effect of the engine related components in engine room. Reducing the component temperature in engine room caused by a sudden temperature deviation can minimize the durability degradation of components. Therefore, in this study, numerical analysis for the development of the hood in engine room was carried out in four parts such as generator, battery, ECU and power steel oil which are relatively easy to control temperature among the main components in engine room. In order to verify the numerical analysis, experiments were conducted under the same conditions as those assumed in the numerical analysis.

Experimental study on the alleviation of micro-pressure waves radiated from the tunnel exit with the slit hoods on the high-speed train operations of 300km/h (300km/h급 고속철도의 터널 미기압파 저감을 위한 슬릿후드의 실험적 연구)

  • Kim, Dong-Hyeon;Min, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.619-624
    • /
    • 2000
  • The purpose of present study is to investigate for reducing micro pressure waves generated according to train speeds $(240km/h{\sim}380km/h)$ through tunnels with countermeasures as followings; the hood configuration in tunnel entrance. We developed hoods for tunnel of 0.5 km length in the condition of tunnel cross-section area of $107m^2$ on the slab track. According to the results the maximum micro-pressure wave is reduced by 41.2% for the slit hood installed at the entrance of the tunnel and reduced by 47.7% for the slit hood installed at the entrance of the tunnel and the $45^{\circ}$ slanted portal at the exit of the tunnel

  • PDF

A Study on the Noise Characteristics of House Range Hoods (주택 주방후드의 소음특성에 관한 연구)

  • Kim, Jin-Ki;Sohn, Jang-Yeul;Cho, Chang-Geun;Shin, Il-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.355-358
    • /
    • 2005
  • This study aims at comparing the noise characteristics of conventional and functional hood. Measurement and analysis was carried out in anechoic room and actual environment. In case of anechoic room, intensity and sound pressure level were measured. In case of actual environment sound pressure level under different apartment size and distances. Sound pressure level of actual environment was higher than that of anechoic room. It is concluded that noise characteristics were different from each other in case of anechoic room and actual environment.

  • PDF