• Title/Summary/Keyword: 횡방향 전단응력

Search Result 44, Processing Time 0.025 seconds

Analysis of Bending Wire Mesh (와이어메쉬 굴곡배치 타당성분석)

  • Kim, Chun-Ho;Jung, Dae-Suk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.6
    • /
    • pp.169-174
    • /
    • 2009
  • We conducted structural analysis to investigate disadvantage of wire-mesh arranged at the plane and to develop three-dimensionally bent U-type wire-mesh. In all case that distributed loading at the whole top slab and the half top slab, and the wire mesh was bent $45^{\circ}$, flexura tensile stress was the fewest in both positive moment and negative moment, and the wire mesh was bent $45^{\circ}$ in crossway the shear stresss was the fewest. Therefore, by arranging wire-mesh with $45^{\circ}$ more bent than plane, flexura tensile stress, shear stress, displacement will be reduced and structural function will be improved.

Horizontal Cracks in Continuously Reinforced Concrete Pavement Structures (연속철근콘크리트 도로포장 구조물의 내부 수평균열)

  • Kim, Seong-Min;Cho, Byoung-Hooi;Kwon, Soon-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.425-429
    • /
    • 2006
  • Horizontal cracks at the mid-depth of concrete slabs were observed at a section of the continuously reinforced concrete pavement(CRCP) structures on the Korea Highway Corporation's Test Road. To investigate the existence and the extent of horizontal cracks in the concrete slab, a number of cores were taken from the section of CRCP. To identify the causes of horizontal cracks, numerical analyses were conducted. Several variables relative to design, material, and environment were considered in the studies to evaluate possible causes of horizontal cracking. A numerical model of CRCP was developed using the finite element discretization, and the shear and normal tensile stress distributions in CRCP were investigated with the model. Numerical analysis results show that the maximum shear and normal tensile stresses develop near the depth of steel bars at transverse cracks. If those maximum stresses reach the strength of concrete, horizontal cracks occur. The maximum stresses become higher as the environmental loads, coefficient of thermal expansion of concrete, and elastic modulus of concrete increase.

Investigation of the Stress Distributions in a Transversely Isotropic Medium Containing a Spheroidal Cavity (구형 공동을 가진 횡 방향 등방성매체의 응력 분포에 관한 연구)

  • 이윤복;전종균
    • Computational Structural Engineering
    • /
    • v.10 no.1
    • /
    • pp.159-171
    • /
    • 1997
  • This study investigates the stress distribution in a transversely isotropic medium containing a spheroidal cavity where the medium is under uniaxial tension in z-direction in one case and pure shear in the plane of isotropy in another case. The technical approach used in this study combines exact analytical and numerical methods. The exact analytical method is based upon three potential functions taken in terms of the Legendre associated functions of the first and second kind. The numerical method is based upon the finite difference approach. Numerical results concerning the two loading conditions with five anisotropic materials are presented.

  • PDF

Evaluation of Structural Performance of Precast Modular Pier Cap (프리캐스트 모듈러 피어캡의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 2015
  • Prefabrication technologies are making bridge construction safer and less disruptive to the environment and traveling public, making bridge designs more constructible and, improving the quality and durability by shifting site work to a more controllable environment. Modular bridge substructures with concrete-filled steel tube (CFT) piers and composite pier caps were suggested to realize accelerated bridge construction. The precast segmental pier cap consists of a composite pier table and precast prestressed segments on the table. The pier table has embedded steel section to mitigate stress concentration at the connection by small tubes. Each bridge pier has four or six CFT columns which connect to the pier cap. Shear strength of the pier cap was obtained by extending vertical reinforcing bars from the table to the precast segment. Transverse prestressing was introduced to control tensile stresses by service loadings. Structural performance of the proposed modular system was evaluated by static tests. Design requirements of the composite pier cap were satisfied by continuous reinforcing bars and prestressing tendons. Standardized modular substructures can be effectively utilized for the fast replacement or construction of bridges.

Comparison of Various Discharge Estimation Methods in Straight Compound Channels (복단면 직선수로의 유량예측방법 비교 연구)

  • Kim, Ji-Sung;Kim, Keuk-Soo;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.238-238
    • /
    • 2011
  • 복단면 하도는 홍수소통을 위한 상부 하도와 생태계 서식처 강화와 유사이송능력 개선, 경제적인 유지유량의 확보 등을 도모하는 자연적인 저수로 하도로 구성된다. 그러므로 갈수기와 홍수기의 유량차가 큰 하천에서, 복단면 하도는 하천 공학, 환경 생태 관점에서 다양한 이점을 제공한다. 그러나 복단면 하도에서의 흐름저항, 조도계수, 통수능, 수위-유량관계, 횡방향 유속분포, 그리고 하상전단응력 분포는 단단면 하도와 상이하며, 중요한 차이점은 주수로부와 홍수터부 사이의 유속차로 인하여 발생하는 활발한 운동량 교환에 의해 추가적인 전단층이 생성되는 점이다. 주수로와 홍수터 사이에서 발생된 경계전단력(Apparent Shear Force, ASF)은 하천의 전반적인 통수능을 감소시켜 홍수의 하도내 저류효과를 증가시킬 수도 있다. 또한 주수로 및 홍수터가 분담할 수 있는 유량은 경계전단력에 민감하기 때문에, 홍수터에 수목 식재, 구조물 설치 등을 계획할 경우 정량적인 항력저항의 산정을 위하여 매우 중요하다. 현재까지 복단면에서 발생하는 경계전단응력을 추정하는 다양한 방법들이 개발되었으며, 각각의 방법으로 부터 경계전단력을 정량적으로 예측할 수 있다. 그러나 대부분의 방법이 실험에 근거한 경험적 방법이므로 각 식의 개발에 사용된 자료에만 적합할 수 있는 한계가 있으며, 균일한 수로의 기하학적 변수(전단면과 주수로의 하폭비, 홍수터와 주수로의 수심비, 홍수터와 주수로의 조도비, 주수로의 하폭대 수심비 등)에 의한 식으로 구성되어 수치모형에서 직접 활용하기에는 한계가 있다. 따라서 본 연구에서는 복단면 경계전단력 산정을 위하여 개발된 다양한 연구결과들을 비교 검토하고, 기존문헌 또는 웹상에서 가용한 수리실험 자료들을 이용하여 각 방법에서 계산된 유량과 실측 유량을 비교함으로써 각 방법이 지닌 한계를 분석하였다. 본 연구에서 검토된 5가지 방법은 Knight and Demetriou (1983)(이하 KD), Wormleaton and Merret (1990)(이하 WM), Cristodoulou (1992), Bousmar and Zech(1999) (이하 BZ) 그리고 Moreta and Martin-Vide (2010)(이하 MM)이다. BZ 방법을 제외하고 나머지 방법들은 전체 유량의 비교에서 5% 이내의 오차를 나타내었다. 그러나 나머지 4가지 방법 중 주수로부 유속의 비교에 있어서는 소규모 수로 실험자료만 이용한 KD 방법이 5% 이상의 오차를 나타내어 정확도가 떨어지는 것으로 나타났다. 따라서 비교적 단순한 형태의 Cristodoulou (1992) 방법이 적용하고자 하는 수로의 규모와 무관하게 복단면 유량예측에 적합할 것으로 판단된다.

  • PDF

The Technical Review of AASHTO LRFD Shear Design (AASHTO LRFD 전단설계방법의 고찰)

  • Jeong, Je-Pyong;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.201-204
    • /
    • 2008
  • The Sectional Design Model(AASHTO LRFD) is appropriate for the design of typical bridge girders, slabs, and other regions of components where the assumptions of traditional engineering beam theory are valid. The shear resistance of a concrete member may be separated into a component, $V_c$, that relies on tensile stresses in the concrete, $V_s$, that relies on tensile stresses in the transverse reinforcement. The expressions for $V_c$ and $V_s$ apply to both prestressed and nonprestressed section, with the terms ${\beta}$ and ${\theta}$ depending on the applied loading(M, V, N, and T) and the properties of the section. With ${\beta}$ taken as 2.0 and ${\theta}$ as 45$^{\circ}$, the expressions for shear strength become essentially identical to those traditionally used for evaluating shear resistance. Recent large-scale experiments, however, have demonstrated that these traditional expression can be seriously unconservative for large members not containing transverse reinforcement. And This paper can present only a brief introduction to shear design of AASHTO LRFD and is to review of the technical difficulty.

  • PDF

Finite Element Formulation Based on Enhanced First-order Shear Deformation Theory for Thermo-mechanical Analysis of Laminated Composite Structures (복합소재 적층 구조물에 대한 열-기계적 거동 예측을 위한 개선된 일차전단변형이론의 유한요소 정식화)

  • Jun-Sik Kim;Dae-Hyeon Na;Jang-Woo Han
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2023
  • This paper proposes a new finite element formulation based on enhanced first-order shear deformation theory including the transverse normal strain effect via the mixed formulation (EFSDTM-TN) for the effective thermo-mechanical analysis of laminated composite structures. The main objective of the EFSDTM-TN is to provide an accurate and efficient solution in describing the thermo-mechanical behavior of laminated composite structures by systematically establishing the relationship between two independent fields (displacement and transverse stress fields) via the mixed formulation. Another key feature is to consider the thermal strain effect without additional unknown variables by introducing a refined transverse displacement field. In the finite element formulation, an eight-node isoparametric plate element is newly developed to implement the advantage of the EFSDTM-TN. Numerical solutions for the thermo-mechanical behavior of laminated composite structures are compared with those available in the open literature to demonstrate the numerical performance of the proposed finite element model.

Higher order zig-zag plate theory for coupled thermo-electric-mechanical smart structures (열-기계-전기 하중 하에서의 지능 복합재 평판 고차이론)

  • Oh, Jin-Ho;Cho, Maeng-Hyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.9-14
    • /
    • 2002
  • A higher order zig-zag plate theory is developed to accurately predict fully coupled mechanical, thermal, and electric behaviors. Both the in-plane displacement and temperature fields through the thickness are constructed by superimposing linear zig-zag field to the smooth globally cubic varying field. Smooth parabolic distribution through the thickness is assumed in the transverse deflection in order to consider transverse normal deformation. Linear zig-zag form is adopted in the electric field. The layer-dependent degrees of freedom of displacement and temperature fields are expressed in tern-is of reference primary degrees of freedom by applying interface continuity conditions as well as bounding surface conditions of transverse shear stresses and transverse heat flux. The numerical examples of coupled and uncoupled analysis demonstrate the accuracy and efficiency of the present theory. The present theory is suitable for the predictions of fully coupled behaviors of thick smart composite plate under mechanical, thermal, and electric loadings combined.

Strength of Compression Lap Splice in Confined Concrete (횡구속된 콘크리트에서 압축이음강도)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.855-858
    • /
    • 2008
  • A compression lap splice can be calculated longer than a tension lap splice in high strength concrete according to current design codes. Including effects of transverse reinforcement, a compression splice becomes much longer than a tension splice. Effects of transverse reinforcement on strength and behavior of compression lap splice, which always exist in actual structures, have been investigated through experimental study of column tests with concrete strength of 40 and 60 MPa. Confined specimens have twice of calculated strengths by current design codes. New design equations for the compression lap splice including the effects of transverse reinforcement are required for practical purpose of ultra-high strength concrete. End bearing is enhanced by transverse reinforcement placed at ends of splice not by transverse reinforcement within splice length. As more transverse reinforcement are placed, the stresses developed by bond linearly increase. The transverse reinforcements at ends of splice a little improve the strength by bond.

  • PDF

Behavior of the Crack Initiation, Transition and Fatigue Crack Growth of Rail Steel (레일강의 균열발생·천이 및 피로균열진전거동)

  • Lee, Jong Sun;Kang, Ki Weon;Choi, Rin;Kim, Jung Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.33-42
    • /
    • 1999
  • In the present study, crack initiation criteria, static failure and tensile mode fatigue behavior for a rail steel are evaluated to assure the railway vehicle's safety. The transverse fissure, which is the most critical damage in the rail, is initiated by the maximum shear stress and its location is subsurface. In addition, the possibility of transition from the shear mode to the mixed mode increases with increasing the length of subsurface crack. Because of the brittleness by the welding, the fracture toughness of the welded part is lower than of the base metal. For low ${\Delta}K$, the stage II fatigue crack growth rates of the welded part is slower than of the base metal but, for high ${\Delta}K$, this different behavior for fatigue crack growth rate is nearly diminished. These trends are more remarkable for low stress ratio, R=0.1. It is believed that this behavior is caused by the change of the microstructure which that of the welded part is coarser than of base metal.

  • PDF