• Title/Summary/Keyword: 회전기

Search Result 2,280, Processing Time 0.028 seconds

Examination of the Flick-Flack Salto Backward Stretched of Success and Fall Occurs on the Balance Beam (평균대 백핸드 수완 동작 성.패 시 실수요인 규명)

  • So, Jae-Moo;Kim, Yoon-Ji;Kim, Yong-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 2008
  • The purpose of this study is to examine the causes of errors from EGR posture on the balance beam, which is bending flick-flack salto backward stretched national team players through kinematic analysis, and present training methods for them so as to provide scientifically useful information to coaches and athlete. Findings from this study are summarized below. The most important factors that affect the errors in boyd center position and speed change were the speed change of left and right body centers and the horizontal and vertical speed changes. The left and right acceleration changes were greater in failed posture than in successful posture. The horizontal and vertical accelerations in E3 and E5 were the key factors that affected the backward somersault and landing. The angular speed changes which varied between success and failure were notable in head and shoulder joints. In individual results. The section when the angular speeds of head and shoulder joint must be the greatest was E4. In this section, when the body is extending instantly in a bent posture, increasing the angular speeds of head, shoulder and hip joints can improve the duration of staying in the air and the rotation radius of a somersault.

Stereotactic Radiosurgery of 26 Intracranial Arteriovenous Malformations with Linear Accelerator (뇌동정맥기형 26예의 선형가속기를 이용한 뇌정위다방향 단일방사선치료)

  • Yoon Sei Chul;Suh Tae Suck;Jang Hong Seok;Choi Kyu Ho;Kim Moon Chan;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 1992
  • From July 1988 through November 1991,26 patients with inoperable arteriovenous malformations were treated with 6 MV linear accelerator at the Kangnam St. Mary's Hospital, Catholic University Medical College. There were 5 females and 21 males with median age of 29 years (range: $6\~63$ years) and median follow up times of 15 months (range: $4\~40$ months). The arteriovenous malformation volumes treated ranged from 1 cm diameter to 3.5 cm rectangular size. The prescribed doses at the isocenter varied from 15 to 30 Gy and were given as a single fraction. To date, all patients performed follow-up not only clinically but also through CT or angiography based radiologic modalities every 6 month. A complete obliteration was achieved in 6 ($23\%$) and partial obliteration in 8 ($31\%$) and no change in 1 ($4\%$). We observed 14 ($54\%$) responsiveness of arteriovenous malformations after radiosurgery by 2 years afterward. Whereas, the decision of the remaining 11 ($42\%$) patients was considered too early to expect the therapeutic response following radiosurgery. No complications through treatment related were observed, yet. Our initial outcome in these first 26 patients with arteriovenous malformations is recommended further follow-up.

  • PDF

A STUDY OF THE CORRELATION BETWEEN THE FEATURES OF MESIODENS AND COMPLICATIONS (상악정중부 과잉치의 양태와 병발증의 상관관계에 관한 연구)

  • Lee, Yoon-Seok;Kim, Jung-Wook;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.275-283
    • /
    • 1999
  • Authors evaluated 152 patients at the department of Pediatric Dentistry in Seoul National University Hospital through clinical records and radiographs. And the following features were studied ; age, sex distribution, number of mesiodens per patients, location, status of eruption, shape and orientation of crown, and complication. From the above results, the relationship between features of mesiodens and complications were evaluated using chi-square analysis. 1. Complications due to the presence of mesiodens did not occur in 31.6%, delayed eruption of adjacent teeth was observed in 33.6%, midline diastema in 22.4%, rotation in 8.6%, displacement in 3.3%, and crowding in 0.7% of all evaluated patients. 2. As compared with the above 8.5 year group, in the under 8.5 year group, the frequency of complications was significantly higher(P<0.05). As compared with those positioned lingually, in mesiodens labially or within the arch the frequency of complications was significantly higher(P<0.01). Also, the frequency of complications was significantly higher when the mesiodens was tuberculate in form(P<0.05). 3. Of the 104 patients with complications, the frequency of delayed eruption was significant higher in the under 8.5 year group, and in above 8.5 year group, the frequency of malocclusion was significantly higher(P<0.05). When mesiodens were located in the midline region, the frequency of malocclusion was significant higher, while in case with laterally positioned mesiodens the frequency of delayed eruption was significantly higher(P<0.01).

  • PDF

Measuring and Generation the speed of reaction wheel for Spacecraft Dynamic Simulator using the T-Method (위성동역학 시뮬레이터용 T-방식을 이용한 반작용휠 속도 측정 및 펄스 생성)

  • Kim, Yong-Bok;Oh, Si-Hwan;Lee, Seon-Ho;Yong, Ki-Lyok;Rhee, Seung-Wu
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.74-82
    • /
    • 2007
  • The M-Method that measures the speed of actuator with counting the number of Reaction wheel Tacho Pulse has the many advantages such that a realization is simple and measuring time is uniform, but it also has the disadvantage that measuring speed becomes worse as the wheel speed goes lower. On the contrary, the T-Method that measures the time duration between the pulses is more accurate at lower-speed and its time delay is smaller than M-Method, but its realization is more difficult than M-Method because measuring time is varying with wheel speed variation. Thought M/T Method mixing M-Method with T-Method is widely used in order to measure the speed in the motor industrial area, one of two methods has been used in the spacecraft design area. Therefore, we try to apply both methods together to measuring the speed of Reaction Wheel, the core actuator for low earth orbit satellite. This paper provides the Reaction Wheel simulation board located in the Spacecraft Dynamic Simulator, ground support test set.

  • PDF

Changes in the pathogenicity of Naegleria fowleri by serial brain passage in mice (자유생활아메바 Naegleria fowleri의 계대감염에 의한 병원성의 변화에 관한 연구)

  • 이득기;임경일
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.234-240
    • /
    • 1983
  • The pathogenicity of free-living amoeba, Waegleria fcwleri, is influenced according to the strain, cultural condition and host (Culbertson et at., 1968; Carter, 1970; Wong et at., 1975), Phillips (1973) demonstrated that Entamoeba histolytica became avirulent after more than 2 year maintenance in axonic culture in vitro. This study was carried out to compare the difference in pathogenicity between two strains of N. fowleri, one of a prolonged maintenance in arsenic medium and the other one obtained by serial brain passage in mice. The 0 strain was that N. fowleri had cultivated axenically more than 7 years in CGVS medium. The 2-1 strain was obtained from the brain of mouse inoculated intranasally with a strain, which was from the mouse brain infected with 0 strain, and cultured for 15 weeks until the beginning of this experiment. White male mice weighing 18-22 g were used. Mice were anesthetized by an intraperitoneal injection of about 1 mg secobarbital, and inoculated intranasally with $10{\times}$10^4 live N. fowleri trophoBoites in a $5{\;}{\mu}l$ cell suspension. Sluggish behaviour, nervousness, rotation and leg paralysis were developed earlier and more frequently in the 2-1 experimental group than the control 0 group. Pathological changes such as inflammatory and necrotic lesion were observed in the olfactory and anterior portion of brain, and these changes were more extensive in the 2-1 group. The edematous and inflammatory changes in lung were demonstrated in mice died after 13th day post-inoculation. The experimental mice of 2-1 group began to die suddenly from 7th day post-inoculation, and the survival time in 2-1 group mice was shorter than 0 group mice. The typical primary amoebic meningoencephalitis was developed in the mice inoculated intranasally with N. fowleri. The prolonged maintenance of N. fowleri amoebae in axonic CGVS medium was observed to have lost their original pathogenicity for mice, but their pathogenicity was restored by serial brain passage in mice.

  • PDF

Study on the pre-beneficiation of low grade scheelite ore using Knelson Concentrator (Knelson Concentrator를 이용한 저품위 회중석의 전처리 기술개발)

  • Jeon, Ho-Seok;Yang, Jeong-Il;Lee, Eun-Seon;Choi, Hee-Kyoung;Baek, Sang-Ho
    • Mineral and Industry
    • /
    • v.26
    • /
    • pp.13-21
    • /
    • 2013
  • This study is carried out experiments on various factors for improving the grade of low grade scheelite by Knelson concentrator prior to the main beneficiation process. Even though there are several gravity separators such as Jig, Spirals and etc. for rougher concentrate, the KC3 Knelson Concentrator was adopted to get better separation efficiency and beneficiating effects for pre-concentration of the low grade scheelite ore. The feed samples was prepared to minus 1mm in size by crushing and grinding. The important factors in the KC3 Knelson Concentrator test were examined in terms of the variations such as number of treatment, feed rate, rotation speed of bowl(G force), water flow rate, pre-removal of magnetic minerals, feed size and feed grade. According to the result of experiment, it shows that the important technical variations are limited in terms of number of treatment, feed rate, feed size and feed grade. The final result shows that the KC3 Knelson Concentrator obtains the scheelite pre-concentrate of about $3%WO_3$ grade and 90% recovery, respectively, from the feed containing about $0.8-1.0%WO_3$ grade.

  • PDF

FeO, $TiH_2$, Carbon 원료분말을 이용한 Fe-TiC 나노 복합분말 제조 및 소결

  • An, Gi-Bong;Kim, Ji-Sun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.26-26
    • /
    • 2011
  • Fe계 TiC 합금은 미량의 합금원소를 첨가시켜 경화능, 내식성, 내마모성 성질을 개선한 특수 공구용 재료로서 현재 절삭, 내마모성, 광산, 금형재료 등의 분야에 널리 사용되고 있다. 금속과 세라믹의 복합재료인 초경합금은 비열처리용 공구강으로 WC, TiC 등의 4, 5, 6족 금속탄화물에 Co, Ni, Fe등의 철족이 결합금속으로 소결한 복합재료로 WC-Co계 초경합금이 주종을 이루고 있으나, 전략 소재로서 고가인 Co 원료를 대체하기 위한 재료로서 초경재료의 고경도와 공구강의 경제성 및 가공성의 장점을 이용한 Fe-TiC계 초경합금의 연구가 다양하게 진행되고 있다. 본 연구에서는 Fe기지에 서브마이크론 크기의 미세한 TiC 입자가 균일하게 분산된 Fe-TiC 복합분말을 경제적으로 제조하기 위해 순수한 Fe, Ti 원료분말에 비해 단가가 낮고 미세 분쇄가 용이한 FeO, $TiH_2$ 분말을 고에너지 밀링 후 반응 열처리 시키는 유사 기계화학적 공정을 시도하였다. 조성비 Fe-30wt%TiC 복합분말을 제조하기위해 마이크론(micron) 크기의 FeO, $TiH_2$, C 분말을 사용하였고, 1단계로 FeO와 C을 고에너지 밀링으로 혼합 후 반응시켜 환원시키는 공정과 2단계로 이렇게 환원된 분말과 TiH2를 고에너지 밀링으로 다시 혼합, 분쇄한 후 반응열처리 하는 두 단계 공정을 사용하였다. FeO의 환원 단계에서는 $700{\sim}1,000^{\circ}C$ 온도 범위에서 1시간 유지하였고, 고에너지 밀링 시 밀링시간, 회전속도를 변수로 두고 실험하였다. 환원된 분말은 수평관상로를 이용해 아르곤분위기에서 $1,000{\sim}1300^{\circ}C$까지 1시간 유지하여 반응열처리시켜 Fe-TiC 복합분말을 제조하였다. 준비된 복합분말을 XRD와 FE-SEM, EDS, 입도분석기 (LPSA) 등을 이용해 분말의 형태와 특성, 상, 조성, 입도, 분산도 등을 조사하였다. 제조된 Fe-TiC 나노복합분말을 방전플라즈마소결(SPS) 과 상압소결 실험을 진행하였다. Fe-TiC 복합분말 제조공정의 첫 번째 단계인 FeO의 환원반응은 $800^{\circ}C$이상의 온도에서 Fe로 환원이 진행됨을 확인하였다. 두 번째 단계인 반응열처리공정에서는 $1,000^{\circ}C$ 이상에서 TiC가 형성됨을 XRD 상분석을 통해 확인할 수 있었고, $1,100^{\circ}C$ 이상의 온도에서 반응열처리를 했을 때 XRD 분석결과와 산소 조성 분석 결과로부터 반응의 완결성과 순도에서 최적 온도 조건임을 확인하였다. 온도를 $1,300^{\circ}C$로 증가시킬 경우 반응의 완결성에 큰 변화가 없는 반면 분말입자간의 목형성이 일어나 가소결 되는 것을 FE-SEM을 통해 관찰하였다. 또한 최적조건으로 제조된 Fe-TiC 복합분말의 입도분석과 FE-SEM/EDS 관찰/분석을 시행한 결과 평균 입도 0.6 ${\mu}m$의 미세한 Fe-TiC 복합분말 내에 Fe분말 주변과 내부에 나노크기의 TiC입자가 균일하게 분산되어 존재하는 것을 확인하였다.

  • PDF

A Study on Useful Application of Stitching Method for Full-Length Examination of the Femur (대퇴골의 전장검사 시 stitching method의 적용에 관한 유용성 연구)

  • Noh, Ji-Sook;Jung, Ji-Hoon;Kim, Sung-Kil;Jung, Myung-Jin
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2011
  • The Full-length examination of the femur sometimes does not show all of the femur because of the limited width in collimator and size of detectors although it is located in the diagonal direction. Aim of this study is to identify usefulness of the method of combining images which obtained from two radiographic images containing the femoral head and condyle respectively. Our group interviewed 30 radiological technologists who used both palliative DR method and SM method in their examinations of the femur of patients who were carried to the emergency rooms in Gwang-ju city from August 2007 to November 2009. We evaluated twenty images according to the contraction of femoral neck, turning of knee joints and inclusion of the femur. The examination were performed by two radiologists and six radiological technologists who have more than ten years of career. The results are as follows: SM method was graded with higher score for examination time, number of examiners, emaciation, retake and patients' discomfort (p< 0.001) while the. SM method was scored higher than the palliative DR method in the palliative DR method for examination of long bone.

EFFECT OF CUTTING INSTRUMENTS ON THE DENTIN BOND STRENGTH OF A SELF-ETCH ADHESIVE (상아질 삭제기구가 자가부식 접착제의 결합강도에 미치는 효과)

  • Lee, Young-Gon;Moon, So-Ra;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.13-19
    • /
    • 2010
  • The purpose of this study was to compare the microshear bond strength of a self-etching primer adhesive to dentin prepared with different diamond points, carbide burs and SiC papers, and also to determine which SiC paper yield similar strength to that of dentinal surface prepared with points or burs. Fifty-six human molar were sectioned to expose the occlusal dentinal surfaces of crowns and slabs of 1.2 mm thick were made. Dentinal surfaces were removed with three diamond points, two carbide burs, and three SiC papers. They were divided into one of eight equal groups (n = 7); Group 1: standard diamond point(TF-12), Group 2: fine diamond point (TF-12F), Group 3: extrafine diamond point (TF-12EF), Group 4: plain-cut carbide bur (no. 245), Group 5: cross-cut carbide bur (no. 557), Group 6 : P 120-grade SiC paper, Group 7: P 220-grade SiC paper, Group 8: P 800-grade SiC paper. Clearfil SE Bond was applied on dentinal surface and Clearfil AP-X was placed on dentinal surface using Tygon tubes. After the bonded specimens were subjected to uSBS testing, the mean uSBS (n = 20 for each group) was statistically compared using one-way ANOV A and Tukey HSD test. In conclusion, the use of extrafine diamond point is recommended for improved bonding of Clearfil SE Bond to dentin. Also the use of P 220-grade SiC paper in vitro will be yield the results closer to dentinal surface prepared with fine diamond point or carbide burs in vivo.

A Study for Automotive Lamp Manufacturing System Control Composing Ultra melting Process (초음파 접합 공정을 합성한 자동차용 램프 생산시스템 제어에 관한 연구)

  • Lee, Il-Kwon;Kook, Chang-Ho;Kim, Seung-Chul;Kim, Ki-Jin;Han, Ki-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • The purpose of this paper is to study of the vehicle lamp manufacturing system composing ultrasonic waves connection process. Making lamp assembly plant, it was produced in the separate process as the injection molding, ultrasonic waves bonding, annealing in the constant temperature, lamp assembling and packing. But the improvement method producing the lamp was added with one-step process by one automation technique. As a result, welding with ultrasonic waves process, the method decreased the energy consumption and noise during ultrasonic waves welding. Therefore, this method used the mathematics modeling for checking validity, it selected the stability and suitable controller using transfer function of plant and bode chart. In this study, the $180^{\circ}$ revolution control system to turn injection part upside down was $M_{eq}\;lcos{\theta}(t)$ because of gravity influence. It effected to unstable condition a system. For solving this problem, it aimed the linearization and stabilization of system by elimination $M_{eq}\;lcos{\theta}(t)$ as applying Free-forward control technique.