• Title/Summary/Keyword: 회로차단기

Search Result 92, Processing Time 0.028 seconds

Development of standby power saving Leakage Breaker (대기전력저감형 누전차단기의 개발)

  • Jang, Hyang-Won;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.35
    • /
    • pp.41-45
    • /
    • 2015
  • This paper presents a development of the ELB (Electronic Leakage Breaker) based on a reduction of standby power dissipation as with maintaining conventional performance. In order to minimize the standby power consumption of the conventional circuit, we analyze the cause of 0.3W dissipation of the circuit. By employing the TR-triggered circuit to secure the standby power of 0.10W after testing and evaluation while CRD inserted circuit showed the performance of 0.17W levels. Implementing SMPS IC and TNR device circuit was designed and showed of its power to less than 0.06W. Developed ELB is expected much standby power savings in large power distributor or heavy users.

  • PDF

The Survey of Periodic Market Electrical Installation (재래시장의 전기설비 실태조사 연구)

  • Lee, Sang-Ick;Kim, Gi-Hyun;Jeon, Hyun-Jae;Bae, Seok-Myung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.329-331
    • /
    • 2008
  • 전기에 의한 화재 발생시 재래시장은 소방안전관리체계나 일관된 지휘체계를 갖추고 있지 않아 화재발생시 적절한 대응을 하지 못해 많은 재산상 피해를 보게 된다. 전기에 의한 화재를 예방하기 위해서는 전기설비의 열화나 고장에 대한 절연저항 측정 또는 누설전류를 측정하는 등의 대책이 있으나 전기설비 열화나 고장은 비가시적이고 비노출식이므로 이를 상시 검출하고 감시할 수 있는 시스템 개발을 필요로 하게 된다. 따라서 본 논문에서는 전기화재에 취약한 재래시장용 전기안전 감시시스템 개발을 위한 준비단계로 먼저 고압이나 저압을 수전 받고 있는 국내 재래시장 17개소에서 수배전반, 분전반 등에 사용하는 차단기들의 종류와 용량 및 상가 분전반에 사용하는 차단기의 종류와 용량, 분기 회로수 등에 대한 조사 분석을 통해 재래시장용 전기안전 감시시스템의 기초자료로 활용하고자 한다.

  • PDF

Impedance of Carbonized Path causing Arc Fault (아크사가 발생할 수 있는 고탄화경로의 임피던스)

  • Kwon, Wan-Sung;Choi, Su-Kyung;Bang, Sun-Bae;Kim, Chong-Min;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.121-122
    • /
    • 2010
  • 전기회로에서 발생하는 아크로 인한 전기화재를 예방할 수 있는 아크차단기(AFCI)의 아크 검출성능 시험규격은 현재 UL1699가 세계적으로 인정되고 있다. 본 논문에서는 여기에 정의된 방법에 따라 탄화경로(Carbonized Path)를 생성하여 모의아크를 발생시켜 보았다. 그에 따른 전압을 가변하여 국내에서 사용되고 있는 전선 및 케이블에 탄화경로를 생성시킬 수 있는 적절한 전원을 제안하고, 아크가 발생한 탄화경로의 임피던스를 측정 및 분석함으로서 UL1699의 아크차단기 성능시험 방법을 검토하고 시험절차의 개선방법을 제안하였다.

  • PDF

Application of Test Standard for Arc-Fault Circuit Interrupter (아크차단기(Arc-Fault Circuit Interrupter)의 시험규격 및 적용)

  • Ahn, Sang-Pil;Moon, Sik;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.876-878
    • /
    • 2003
  • 아크차단기(Arc-Fault Circuit Interrupter:AFCI)는 주택의 배선회로에서 아크가 발생하였을 경우 위험한 아크를 검출하여 차단하는 기능을 지니고 있다. 미국에서는 1993년부터 AFCI를 개발하기 시작하여 1997년 후반에 최초의 상압용 AFCI 제품을 출시하였다. 또한 UL(Underwriters Laboratories Inc.)에서는 1999년 2월에 AFCI에 대한 최초의 제품규격인 UL1699를 출간하였다[1-5]. 본 논문에서는 AFCI에 대한 유일한 시험규격인 UL1699를 정리해 보고, 특히 AFCI의 고유기능인 아크검출기능을 시험할 수 있는 시험항목과 AFCI의 분류별 시험항목을 분석하였다.

  • PDF

Implementation of Solid-State Circuit Breaker for DC gird (DC 그리드를 위한 Solid-State Circuit Breaker의 구현)

  • Kim, Jin-Young;Sim, Jae-Hyeok;Kim, In-Dong;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.111-112
    • /
    • 2012
  • 전력효율을 높일 수 있는 DC 전송이 주요 관심사가 됨에 따라 전력품질에 대한 기술이 요구된다. DC 그리드의 전력품질을 위해서는 반도체 차단기(Solid-State Circuit Breaker : SSCB)는 필수요소이다. 하지만 기존의 반도체 차단기는 AC 그리드에 기반을 두고 제안되었기 때문에 DC 그리드에 적용하기 어렵다. 따라서 본 연구에서는 DC 그리드에 적용 가능한 SSCB (Solid-State Circuit Breaker : SSCB)을 제안한다. 제안하는 DC SSCB는 사고 전류를 제한하며 사고 지점의 신속한 차단이 가능하다. 제안한 회로는 시뮬레이션을 통해 단락 사고를 모의하여 시스템의 동작 특성을 검증하였다.

  • PDF

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

Design of Active Power Filter for Safe Operation of Electrical Equipments (전기설비 안전에 필요한 능동 전력 필터 설계)

  • Jeong, Jae-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.176-178
    • /
    • 2008
  • 최근 전력전자 기기와 같은 비선형 부하의 증가로 계통에서 고조파 발생 가능성은 점점 높아지는 추세이다 이러한 계통의 고조파는 부하 설비 중 누전차단기 오동작 및 과부하 등의 원인이 되므로 전기설비 안전 측면에서 중요하게 다루어질 필요가 있다. 고조파에 대한 해결책으로는 수동필터 및 능동전력필터를 들 수 있는데 본 연구에서는 기존의 3상 풀브리지 스위칭 회로를 이용한 능동필터에 비해 안정성 및 대용량 시스템 구성에 유리한 모듈형 능동 전력 필터를 제안하였다.

  • PDF

EMTP Modeling of an Alterative Counter voltage (ACV) DC Hybrid Circuit Breaker (DC-HCB) (대체 카운터 전압(ACV) DC 하이브리드 회로 차단기(DC-HCB)의 EMTP 모델링)

  • Kazim, Raza Muhammad;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.601-602
    • /
    • 2015
  • Interruption of AC is easier due to natural occuring of zero crossings. In DC, zero crossings is achieved by Forced commutation technique. In this paper an alternative counter voltage(ACV) DC Hybrid Circuit breaker(DC-HCB) is modeled using EMTP/ATP tool, Results show that, ACV DC-HCB can interrupt DC with in 5ms with a source voltage of upto 1 KV.

  • PDF

DC Solid-State Circuit Breaker with Simple Structure (간단한 구조를 갖는 DC Solid-State Circuit Breaker)

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.495-496
    • /
    • 2013
  • 전력효율을 높일 수 있는 DC 전송이 주요 관심사가 됨에 따라 전력품질에 대한 기술이 요구된다. DC 그리드의 전력품질을 위해서는 반도체 차단기(Solid-State Circuit Breaker : SSCB)는 필수요소이다. 따라서 본 연구에서는 DC 그리드에 적용 가능한 SSCB (Solid-State Circuit Breaker : SSCB)을 제안한다. 제안한 회로는 단락 사고를 모의하고 시뮬레이션과 실험을 통해 시스템의 동작 특성을 검증하였다.

  • PDF

Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function (데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung;Joo, Nam-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.